Loading…

Generator reactive power limits and voltage stability

Generator reactive power limit is a key factor in voltage instability. When the field or armature current limit becomes active, the generator reactive power limit becomes voltage dependent. These operational limits and the shifting between field limit and armature limit, are fully investigated. Furt...

Full description

Saved in:
Bibliographic Details
Main Authors: Efthymiadis, A.E, Guo, Y.-H
Format: Conference Proceeding
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c145t-f2406efe853f2fdc653e1d095c9a81f1d28d6f44cfb0e559799c4a10b5467cde3
cites
container_end_page 199
container_issue
container_start_page 196
container_title
container_volume
creator Efthymiadis, A.E
Guo, Y.-H
description Generator reactive power limit is a key factor in voltage instability. When the field or armature current limit becomes active, the generator reactive power limit becomes voltage dependent. These operational limits and the shifting between field limit and armature limit, are fully investigated. Further, careful examination of generator reactive power characteristics, reveals the effect of generator reactive power capability on system voltage stability. It is shown that a generator can be active or passive in supporting voltage stability, even when its reactive power is limited. An indicator is proposed for identifying critical generators, based on this observation.
doi_str_mv 10.1049/cp:19960263
format conference_proceeding
fullrecord <record><control><sourceid>iet</sourceid><recordid>TN_cdi_iet_conferences_10_1049_cp_19960263</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1049_cp_19960263</sourcerecordid><originalsourceid>FETCH-LOGICAL-c145t-f2406efe853f2fdc653e1d095c9a81f1d28d6f44cfb0e559799c4a10b5467cde3</originalsourceid><addsrcrecordid>eNo1j8FKxDAURQMiKGNX_kDWQvUlTdLEnQw6CgNudB3SlxeJ1LY0YcS_d0Q9m7s73MPYpYBrAcrd4HIrnDMgTXfCGtdbsFo6Y3Qnz1hTyjscUVqAhHOmdzTRGuq88pUC1nwgvsyftPIxf-RaeJgiP8xjDW_ESw1DHnP9umCnKYyFmr_dsNeH-5ftY7t_3j1t7_YtCqVrm6QCQ4ms7pJMEY8XSERwGl2wIokobTRJKUwDkNaudw5VEDBoZXqM1G3Y1a83U_U4T4lWmpCKF-B_Wj0u_r-1-wZz0EiI</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Generator reactive power limits and voltage stability</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Efthymiadis, A.E ; Guo, Y.-H</creator><creatorcontrib>Efthymiadis, A.E ; Guo, Y.-H</creatorcontrib><description>Generator reactive power limit is a key factor in voltage instability. When the field or armature current limit becomes active, the generator reactive power limit becomes voltage dependent. These operational limits and the shifting between field limit and armature limit, are fully investigated. Further, careful examination of generator reactive power characteristics, reveals the effect of generator reactive power capability on system voltage stability. It is shown that a generator can be active or passive in supporting voltage stability, even when its reactive power is limited. An indicator is proposed for identifying critical generators, based on this observation.</description><identifier>ISBN: 9780852966532</identifier><identifier>ISBN: 0852966539</identifier><identifier>DOI: 10.1049/cp:19960263</identifier><language>eng</language><publisher>London: IEE</publisher><subject>Control of electric power systems ; Control system analysis and synthesis methods ; Generating stations and plants ; Power and energy control ; Power system management, operation and economics ; Stability in control theory</subject><ispartof>Fourth International Conference on Power System Control and Management, 1996, p.196-199</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c145t-f2406efe853f2fdc653e1d095c9a81f1d28d6f44cfb0e559799c4a10b5467cde3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,776,780,785,786,4035,4036,27904</link.rule.ids></links><search><creatorcontrib>Efthymiadis, A.E</creatorcontrib><creatorcontrib>Guo, Y.-H</creatorcontrib><title>Generator reactive power limits and voltage stability</title><title>Fourth International Conference on Power System Control and Management</title><description>Generator reactive power limit is a key factor in voltage instability. When the field or armature current limit becomes active, the generator reactive power limit becomes voltage dependent. These operational limits and the shifting between field limit and armature limit, are fully investigated. Further, careful examination of generator reactive power characteristics, reveals the effect of generator reactive power capability on system voltage stability. It is shown that a generator can be active or passive in supporting voltage stability, even when its reactive power is limited. An indicator is proposed for identifying critical generators, based on this observation.</description><subject>Control of electric power systems</subject><subject>Control system analysis and synthesis methods</subject><subject>Generating stations and plants</subject><subject>Power and energy control</subject><subject>Power system management, operation and economics</subject><subject>Stability in control theory</subject><isbn>9780852966532</isbn><isbn>0852966539</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1996</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNo1j8FKxDAURQMiKGNX_kDWQvUlTdLEnQw6CgNudB3SlxeJ1LY0YcS_d0Q9m7s73MPYpYBrAcrd4HIrnDMgTXfCGtdbsFo6Y3Qnz1hTyjscUVqAhHOmdzTRGuq88pUC1nwgvsyftPIxf-RaeJgiP8xjDW_ESw1DHnP9umCnKYyFmr_dsNeH-5ftY7t_3j1t7_YtCqVrm6QCQ4ms7pJMEY8XSERwGl2wIokobTRJKUwDkNaudw5VEDBoZXqM1G3Y1a83U_U4T4lWmpCKF-B_Wj0u_r-1-wZz0EiI</recordid><startdate>1996</startdate><enddate>1996</enddate><creator>Efthymiadis, A.E</creator><creator>Guo, Y.-H</creator><general>IEE</general><scope>8ET</scope></search><sort><creationdate>1996</creationdate><title>Generator reactive power limits and voltage stability</title><author>Efthymiadis, A.E ; Guo, Y.-H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c145t-f2406efe853f2fdc653e1d095c9a81f1d28d6f44cfb0e559799c4a10b5467cde3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Control of electric power systems</topic><topic>Control system analysis and synthesis methods</topic><topic>Generating stations and plants</topic><topic>Power and energy control</topic><topic>Power system management, operation and economics</topic><topic>Stability in control theory</topic><toplevel>online_resources</toplevel><creatorcontrib>Efthymiadis, A.E</creatorcontrib><creatorcontrib>Guo, Y.-H</creatorcontrib><collection>IET Conference Publications by volume</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Efthymiadis, A.E</au><au>Guo, Y.-H</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Generator reactive power limits and voltage stability</atitle><btitle>Fourth International Conference on Power System Control and Management</btitle><date>1996</date><risdate>1996</risdate><spage>196</spage><epage>199</epage><pages>196-199</pages><isbn>9780852966532</isbn><isbn>0852966539</isbn><abstract>Generator reactive power limit is a key factor in voltage instability. When the field or armature current limit becomes active, the generator reactive power limit becomes voltage dependent. These operational limits and the shifting between field limit and armature limit, are fully investigated. Further, careful examination of generator reactive power characteristics, reveals the effect of generator reactive power capability on system voltage stability. It is shown that a generator can be active or passive in supporting voltage stability, even when its reactive power is limited. An indicator is proposed for identifying critical generators, based on this observation.</abstract><cop>London</cop><pub>IEE</pub><doi>10.1049/cp:19960263</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISBN: 9780852966532
ispartof Fourth International Conference on Power System Control and Management, 1996, p.196-199
issn
language eng
recordid cdi_iet_conferences_10_1049_cp_19960263
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Control of electric power systems
Control system analysis and synthesis methods
Generating stations and plants
Power and energy control
Power system management, operation and economics
Stability in control theory
title Generator reactive power limits and voltage stability
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T17%3A25%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iet&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Generator%20reactive%20power%20limits%20and%20voltage%20stability&rft.btitle=Fourth%20International%20Conference%20on%20Power%20System%20Control%20and%20Management&rft.au=Efthymiadis,%20A.E&rft.date=1996&rft.spage=196&rft.epage=199&rft.pages=196-199&rft.isbn=9780852966532&rft.isbn_list=0852966539&rft_id=info:doi/10.1049/cp:19960263&rft_dat=%3Ciet%3E10_1049_cp_19960263%3C/iet%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c145t-f2406efe853f2fdc653e1d095c9a81f1d28d6f44cfb0e559799c4a10b5467cde3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true