Loading…
Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications
We investigate novel methods for the quantification of platelet responsiveness that are suited for implementation in lab-on-a-chip devices. Magnetic beads are convenient carriers for rapid capture and manipulation of biological cells in a miniaturized system. In this article, we demonstrate that ant...
Saved in:
Published in: | Platelets (Edinburgh) 2012-12, Vol.23 (8), p.626-632 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3 |
---|---|
cites | cdi_FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3 |
container_end_page | 632 |
container_issue | 8 |
container_start_page | 626 |
container_title | Platelets (Edinburgh) |
container_volume | 23 |
creator | Van Zijp, Helena M. Schot, Claudia C.M.M. De Jong, Arthur M. Jongmans, Nona Van Holten, Thijs C. Roest, Mark Prins, Menno W.J. |
description | We investigate novel methods for the quantification of platelet responsiveness that are suited for implementation in lab-on-a-chip devices. Magnetic beads are convenient carriers for rapid capture and manipulation of biological cells in a miniaturized system. In this article, we demonstrate that antibody-coated magnetic beads can be used to quantify platelet responsiveness. We use anti-CD62P coated beads to capture activated platelets from samples stimulated with a PAR-1 specific agonist SFLLRN, also known as thrombin receptor activator peptide. The responsiveness of the platelets is analyzed via the remaining unbound platelets in the solution and compared to a reference method in which the number of activated platelets is analyzed via fluorescent labeling. The effective concentrations for platelet activation are in agreement for the two assay types, proving that platelet responsiveness can be quantified using antibody-coated magnetic beads. We discuss the outlook for application in lab-on-a-chip devices. |
doi_str_mv | 10.3109/09537104.2011.651516 |
format | article |
fullrecord | <record><control><sourceid>proquest_infor</sourceid><recordid>TN_cdi_informahealthcare_journals_10_3109_09537104_2011_651516</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1151032682</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3</originalsourceid><addsrcrecordid>eNp9kE1v1DAQhi1ERbeFf4CQj1yy-CPxJhcQqsqHVNQLnK2JM-565djBdlrtv2-ibZG49DSX531n5iHkPWdbyVn3iXWN3HFWbwXjfKsa3nD1imy4VF3FlWxek82KVCtzTi5yPjDGW6aaN-RcCMk6Vu825PALIc8JRwyFRksnDwU9FpowTzFkd48Bc6ZzduGOQiiuj8OxMnHBBjrCXcDiDO0RhkxtTNRDX8VQQWX2bqIwTd4ZKG6pekvOLPiM757mJfnz7fr31Y_q5vb7z6uvN5WpeVuq3hoUnO-Y6urOsr5FMNDVUlnOW9MMu3751NStUaLhrEHTClSia5mUvbX9IC_Jx1PvlOLfGXPRo8sGvYeAcc6aL3kmhWrFgtYn1KSYc0Krp-RGSEfNmV4t62fLerWsT5aX2IenDXM_4vAv9Kx1Ab6cABcWJyM8xOQHXeDoY7IJgnF5rX9xxef_GvYIvuwNJNSHOKewCHz5xkdIyKBz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1151032682</pqid></control><display><type>article</type><title>Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list)</source><creator>Van Zijp, Helena M. ; Schot, Claudia C.M.M. ; De Jong, Arthur M. ; Jongmans, Nona ; Van Holten, Thijs C. ; Roest, Mark ; Prins, Menno W.J.</creator><creatorcontrib>Van Zijp, Helena M. ; Schot, Claudia C.M.M. ; De Jong, Arthur M. ; Jongmans, Nona ; Van Holten, Thijs C. ; Roest, Mark ; Prins, Menno W.J.</creatorcontrib><description>We investigate novel methods for the quantification of platelet responsiveness that are suited for implementation in lab-on-a-chip devices. Magnetic beads are convenient carriers for rapid capture and manipulation of biological cells in a miniaturized system. In this article, we demonstrate that antibody-coated magnetic beads can be used to quantify platelet responsiveness. We use anti-CD62P coated beads to capture activated platelets from samples stimulated with a PAR-1 specific agonist SFLLRN, also known as thrombin receptor activator peptide. The responsiveness of the platelets is analyzed via the remaining unbound platelets in the solution and compared to a reference method in which the number of activated platelets is analyzed via fluorescent labeling. The effective concentrations for platelet activation are in agreement for the two assay types, proving that platelet responsiveness can be quantified using antibody-coated magnetic beads. We discuss the outlook for application in lab-on-a-chip devices.</description><identifier>ISSN: 0953-7104</identifier><identifier>EISSN: 1369-1635</identifier><identifier>DOI: 10.3109/09537104.2011.651516</identifier><identifier>PMID: 22309047</identifier><language>eng</language><publisher>England: Informa UK, Ltd</publisher><subject>Antibodies - chemistry ; Antibodies - immunology ; Antibodies - pharmacology ; beads ; Blood Platelets - cytology ; Blood Platelets - drug effects ; capture assay ; CD62P ; dose response ; Fluorescent Dyes ; Humans ; Lab-On-A-Chip Devices ; Magnets ; P-Selectin - chemistry ; P-Selectin - immunology ; Platelet activation ; Platelet Activation - drug effects ; Receptor, PAR-1 - agonists ; Receptor, PAR-1 - metabolism ; Receptors, Thrombin - metabolism ; Reproducibility of Results ; Sensitivity and Specificity</subject><ispartof>Platelets (Edinburgh), 2012-12, Vol.23 (8), p.626-632</ispartof><rights>2012 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2012</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3</citedby><cites>FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22309047$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Van Zijp, Helena M.</creatorcontrib><creatorcontrib>Schot, Claudia C.M.M.</creatorcontrib><creatorcontrib>De Jong, Arthur M.</creatorcontrib><creatorcontrib>Jongmans, Nona</creatorcontrib><creatorcontrib>Van Holten, Thijs C.</creatorcontrib><creatorcontrib>Roest, Mark</creatorcontrib><creatorcontrib>Prins, Menno W.J.</creatorcontrib><title>Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications</title><title>Platelets (Edinburgh)</title><addtitle>Platelets</addtitle><description>We investigate novel methods for the quantification of platelet responsiveness that are suited for implementation in lab-on-a-chip devices. Magnetic beads are convenient carriers for rapid capture and manipulation of biological cells in a miniaturized system. In this article, we demonstrate that antibody-coated magnetic beads can be used to quantify platelet responsiveness. We use anti-CD62P coated beads to capture activated platelets from samples stimulated with a PAR-1 specific agonist SFLLRN, also known as thrombin receptor activator peptide. The responsiveness of the platelets is analyzed via the remaining unbound platelets in the solution and compared to a reference method in which the number of activated platelets is analyzed via fluorescent labeling. The effective concentrations for platelet activation are in agreement for the two assay types, proving that platelet responsiveness can be quantified using antibody-coated magnetic beads. We discuss the outlook for application in lab-on-a-chip devices.</description><subject>Antibodies - chemistry</subject><subject>Antibodies - immunology</subject><subject>Antibodies - pharmacology</subject><subject>beads</subject><subject>Blood Platelets - cytology</subject><subject>Blood Platelets - drug effects</subject><subject>capture assay</subject><subject>CD62P</subject><subject>dose response</subject><subject>Fluorescent Dyes</subject><subject>Humans</subject><subject>Lab-On-A-Chip Devices</subject><subject>Magnets</subject><subject>P-Selectin - chemistry</subject><subject>P-Selectin - immunology</subject><subject>Platelet activation</subject><subject>Platelet Activation - drug effects</subject><subject>Receptor, PAR-1 - agonists</subject><subject>Receptor, PAR-1 - metabolism</subject><subject>Receptors, Thrombin - metabolism</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><issn>0953-7104</issn><issn>1369-1635</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9kE1v1DAQhi1ERbeFf4CQj1yy-CPxJhcQqsqHVNQLnK2JM-565djBdlrtv2-ibZG49DSX531n5iHkPWdbyVn3iXWN3HFWbwXjfKsa3nD1imy4VF3FlWxek82KVCtzTi5yPjDGW6aaN-RcCMk6Vu825PALIc8JRwyFRksnDwU9FpowTzFkd48Bc6ZzduGOQiiuj8OxMnHBBjrCXcDiDO0RhkxtTNRDX8VQQWX2bqIwTd4ZKG6pekvOLPiM757mJfnz7fr31Y_q5vb7z6uvN5WpeVuq3hoUnO-Y6urOsr5FMNDVUlnOW9MMu3751NStUaLhrEHTClSia5mUvbX9IC_Jx1PvlOLfGXPRo8sGvYeAcc6aL3kmhWrFgtYn1KSYc0Krp-RGSEfNmV4t62fLerWsT5aX2IenDXM_4vAv9Kx1Ab6cABcWJyM8xOQHXeDoY7IJgnF5rX9xxef_GvYIvuwNJNSHOKewCHz5xkdIyKBz</recordid><startdate>201212</startdate><enddate>201212</enddate><creator>Van Zijp, Helena M.</creator><creator>Schot, Claudia C.M.M.</creator><creator>De Jong, Arthur M.</creator><creator>Jongmans, Nona</creator><creator>Van Holten, Thijs C.</creator><creator>Roest, Mark</creator><creator>Prins, Menno W.J.</creator><general>Informa UK, Ltd</general><general>Taylor & Francis</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201212</creationdate><title>Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications</title><author>Van Zijp, Helena M. ; Schot, Claudia C.M.M. ; De Jong, Arthur M. ; Jongmans, Nona ; Van Holten, Thijs C. ; Roest, Mark ; Prins, Menno W.J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Antibodies - chemistry</topic><topic>Antibodies - immunology</topic><topic>Antibodies - pharmacology</topic><topic>beads</topic><topic>Blood Platelets - cytology</topic><topic>Blood Platelets - drug effects</topic><topic>capture assay</topic><topic>CD62P</topic><topic>dose response</topic><topic>Fluorescent Dyes</topic><topic>Humans</topic><topic>Lab-On-A-Chip Devices</topic><topic>Magnets</topic><topic>P-Selectin - chemistry</topic><topic>P-Selectin - immunology</topic><topic>Platelet activation</topic><topic>Platelet Activation - drug effects</topic><topic>Receptor, PAR-1 - agonists</topic><topic>Receptor, PAR-1 - metabolism</topic><topic>Receptors, Thrombin - metabolism</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Van Zijp, Helena M.</creatorcontrib><creatorcontrib>Schot, Claudia C.M.M.</creatorcontrib><creatorcontrib>De Jong, Arthur M.</creatorcontrib><creatorcontrib>Jongmans, Nona</creatorcontrib><creatorcontrib>Van Holten, Thijs C.</creatorcontrib><creatorcontrib>Roest, Mark</creatorcontrib><creatorcontrib>Prins, Menno W.J.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Platelets (Edinburgh)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Van Zijp, Helena M.</au><au>Schot, Claudia C.M.M.</au><au>De Jong, Arthur M.</au><au>Jongmans, Nona</au><au>Van Holten, Thijs C.</au><au>Roest, Mark</au><au>Prins, Menno W.J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications</atitle><jtitle>Platelets (Edinburgh)</jtitle><addtitle>Platelets</addtitle><date>2012-12</date><risdate>2012</risdate><volume>23</volume><issue>8</issue><spage>626</spage><epage>632</epage><pages>626-632</pages><issn>0953-7104</issn><eissn>1369-1635</eissn><abstract>We investigate novel methods for the quantification of platelet responsiveness that are suited for implementation in lab-on-a-chip devices. Magnetic beads are convenient carriers for rapid capture and manipulation of biological cells in a miniaturized system. In this article, we demonstrate that antibody-coated magnetic beads can be used to quantify platelet responsiveness. We use anti-CD62P coated beads to capture activated platelets from samples stimulated with a PAR-1 specific agonist SFLLRN, also known as thrombin receptor activator peptide. The responsiveness of the platelets is analyzed via the remaining unbound platelets in the solution and compared to a reference method in which the number of activated platelets is analyzed via fluorescent labeling. The effective concentrations for platelet activation are in agreement for the two assay types, proving that platelet responsiveness can be quantified using antibody-coated magnetic beads. We discuss the outlook for application in lab-on-a-chip devices.</abstract><cop>England</cop><pub>Informa UK, Ltd</pub><pmid>22309047</pmid><doi>10.3109/09537104.2011.651516</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0953-7104 |
ispartof | Platelets (Edinburgh), 2012-12, Vol.23 (8), p.626-632 |
issn | 0953-7104 1369-1635 |
language | eng |
recordid | cdi_informahealthcare_journals_10_3109_09537104_2011_651516 |
source | Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Medical Collection (Reading list) |
subjects | Antibodies - chemistry Antibodies - immunology Antibodies - pharmacology beads Blood Platelets - cytology Blood Platelets - drug effects capture assay CD62P dose response Fluorescent Dyes Humans Lab-On-A-Chip Devices Magnets P-Selectin - chemistry P-Selectin - immunology Platelet activation Platelet Activation - drug effects Receptor, PAR-1 - agonists Receptor, PAR-1 - metabolism Receptors, Thrombin - metabolism Reproducibility of Results Sensitivity and Specificity |
title | Measurement of platelet responsiveness using antibody-coated magnetic beads for lab-on-a-chip applications |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T14%3A40%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20platelet%20responsiveness%20using%20antibody-coated%20magnetic%20beads%20for%20lab-on-a-chip%20applications&rft.jtitle=Platelets%20(Edinburgh)&rft.au=Van%20Zijp,%20Helena%20M.&rft.date=2012-12&rft.volume=23&rft.issue=8&rft.spage=626&rft.epage=632&rft.pages=626-632&rft.issn=0953-7104&rft.eissn=1369-1635&rft_id=info:doi/10.3109/09537104.2011.651516&rft_dat=%3Cproquest_infor%3E1151032682%3C/proquest_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c418t-bfce211706949f0b8eaca9436f118c5d7b151c48c625105ec82e6298033bffbd3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1151032682&rft_id=info:pmid/22309047&rfr_iscdi=true |