An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples

Abstract Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F2-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laborator...

Full description

Saved in:
Bibliographic Details
Published in:Free radical research 2010-10, Vol.44 (10), p.1203-1215
Main Authors: Breusing, Nicolle, Grune, Tilman, Andrisic, Luka, Atalay, Mustafa, Bartosz, Grzegorz, Biasi, Fiorella, Borovic, Suzana, Bravo, Laura, Casals, Isidre, Casillas, Rosario, Dinischiotu, Anca, Drzewinska, Joanna, Faber, Heidemarie, Fauzi, Norsyahida Mohd, Gajewska, Agnieszka, Gambini, Juan, Gradinaru, Daniela, Kokkola, Tarja, Lojek, Antonin, uczaj, Wojciech, Margina, Denisa, Mascia, Cinzia, Mateos, Raquel, Meinitzer, Andreas, Mitjavila, MarĂ­a Teresa, Mrakovcic, Lidija, Munteanu, Maria Cristina, Podborska, Martina, Poli, Giuseppe, Sicinska, Paulina, Skrzydlewska, Elzbieta, Vina, Jose, Wiswedel, Ingrid, Zarkovic, Neven, Zelzer, Sieglinde, Spickett, Corinne M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F2-isoprostanes are widely used as markers of oxidative stress in vitro and in vivo. This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coefficients of variation were observed between the laboratories. Malondialdehyde determined by HPLC was found to be the most sensitive and reproducible lipid peroxidation product in plasma upon UVA treatment. It is concluded that measurement of malondialdehyde by HPLC has good analytical validity for inter-laboratory studies on lipid peroxidation in human EDTA-plasma samples, although it is acknowledged that this may not translate to biological validity.
ISSN:1071-5762
1029-2470
DOI:10.3109/10715762.2010.499907