An H2 norm approach for the actuator and sensor placement in vibration control of a smart structure

In active vibration control of smart structures, the actuator and sensor placement is a key point of the control system design. Even the most robust control logics could easily make a structure unstable if the actuators and sensors were not correctly positioned. The objective of this paper is to pro...

Full description

Saved in:
Bibliographic Details
Published in:Smart materials and structures 2012-12, Vol.21 (12)
Main Authors: Ambrosio, P, Resta, F, Ripamonti, F
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In active vibration control of smart structures, the actuator and sensor placement is a key point of the control system design. Even the most robust control logics could easily make a structure unstable if the actuators and sensors were not correctly positioned. The objective of this paper is to propose an H2 norm approach for the actuator and sensor placement. Unlike most modal H2 norm actuator and sensor placement methodologies, this work aims not only to maximize the norms of the controlled modes but also to reduce spillover problems by taking into account the residual modes and minimizing their H2 norms. It discusses the optimal actuator and sensor configuration in a finite element model of a square plate fixed on three sides with piezoelectric patch actuators and acceleration sensors. Finally, downstream of the actuator and sensor positioning, IMSC, PPF and NDF controls have been tested and discussed.
ISSN:0964-1726
1361-665X
DOI:10.1088/0964-1726/21/12/125016