Loading…

Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement

It is of crucial interest to observe fluids and measure their properties in the field of process engineering. Capacitive measurement techniques have the advantage of being low-cost and having the ability to distinguish between higher-permittivity liquids such as water and gases such as air. A possib...

Full description

Saved in:
Bibliographic Details
Published in:Measurement science & technology 2019-04, Vol.30 (4), p.45101
Main Authors: Kandlbinder-Paret, Christoph, Fischerauer, Alice, Fischerauer, Gerhard
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3
cites cdi_FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3
container_end_page
container_issue 4
container_start_page 45101
container_title Measurement science & technology
container_volume 30
creator Kandlbinder-Paret, Christoph
Fischerauer, Alice
Fischerauer, Gerhard
description It is of crucial interest to observe fluids and measure their properties in the field of process engineering. Capacitive measurement techniques have the advantage of being low-cost and having the ability to distinguish between higher-permittivity liquids such as water and gases such as air. A possible application for this technique is the non-invasive and non-intrusive determination of the water fill level in a pipe. In this paper we report on the design, implementation, and test of such a capacitive measurement system and on the finite element (FE) modeling of the system and typical application cases. The system consists of electrodes that are mounted around the circumference of a polycarbonate pipe. These elementary electrodes can be combined electronically via software to form larger 'synthetic' electrodes. The capacitances between the electrodes are measured to obtain information about the phase distribution inside the pipe (liquid or gaseous). While the spatial resolution depends on the size of the configurable electrodes, it is possible to first obtain coarse fill level information with larger electrodes and then obtain refined spatial resolution with a small-electrode configuration in a smaller region of interest. The disadvantage of using smaller electrodes is that the measurement time increases. The system was tested on a test bench with a pipe in which the liquid could be made to slosh by axial movements. The results of capacitance measurements in a 16-electrode system were compared to FE simulation results in Ansys. The results of the simulation were used to create a characteristic curve for the fill level as a function of the capacitance of every electrode combination. The fill level change was also observed optically to identify the most appropriate electrode combinations to fit the fill-level change best. An algorithm was developed to choose suitable 'essential' electrode combinations for adaptive spatial resolution refinement. In the end, 28 capacitance measurements were needed to observe the sloshing in a coarse way, followed by 56 measurements for resolution enhancement. The straightforward approach based on the 16 elementary electrodes would have required 120 measurements. It is also shown that the resolution enhancement using the 56 electrode combinations can determine the fill level more accurately than the standard approach using the information from all 120 electrode combinations.
doi_str_mv 10.1088/1361-6501/ab0486
format article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6501_ab0486</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>mstab0486</sourcerecordid><originalsourceid>FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7ePebmxbqTpl85yuKqsOBFzyFNJrtZ2qYkrbL_3pYVT-JpYHifl5mHkFsGDwyqasV4wZIiB7ZSNWRVcUYWv6tzsgCRlwmknF-SqxgPAFCCEAsSN65pkgY_saEtqjgGbLEb6Bhdt6Na9Uq7QXUaacQu-hDplxv2VBnVD26CjlT7zrrdGFTdIMUG9RC8wUitDzRg9M04ON9R7PZzzVx-TS6saiLe_Mwl-dg8va9fku3b8-v6cZtonokhKbMCKmO5ghREyiwXRVVXCoS1eSYKlaa2rHNAFCbjxhpdlVlZC60m0Ojc8CWBU68OPsaAVvbBtSocJQM5S5OzITkbkidpE3J_Qpzv5cGPoZsO_C9-90e8jYPkIDMJWc6mcD898Q0p-H4a</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement</title><source>Institute of Physics</source><creator>Kandlbinder-Paret, Christoph ; Fischerauer, Alice ; Fischerauer, Gerhard</creator><creatorcontrib>Kandlbinder-Paret, Christoph ; Fischerauer, Alice ; Fischerauer, Gerhard</creatorcontrib><description>It is of crucial interest to observe fluids and measure their properties in the field of process engineering. Capacitive measurement techniques have the advantage of being low-cost and having the ability to distinguish between higher-permittivity liquids such as water and gases such as air. A possible application for this technique is the non-invasive and non-intrusive determination of the water fill level in a pipe. In this paper we report on the design, implementation, and test of such a capacitive measurement system and on the finite element (FE) modeling of the system and typical application cases. The system consists of electrodes that are mounted around the circumference of a polycarbonate pipe. These elementary electrodes can be combined electronically via software to form larger 'synthetic' electrodes. The capacitances between the electrodes are measured to obtain information about the phase distribution inside the pipe (liquid or gaseous). While the spatial resolution depends on the size of the configurable electrodes, it is possible to first obtain coarse fill level information with larger electrodes and then obtain refined spatial resolution with a small-electrode configuration in a smaller region of interest. The disadvantage of using smaller electrodes is that the measurement time increases. The system was tested on a test bench with a pipe in which the liquid could be made to slosh by axial movements. The results of capacitance measurements in a 16-electrode system were compared to FE simulation results in Ansys. The results of the simulation were used to create a characteristic curve for the fill level as a function of the capacitance of every electrode combination. The fill level change was also observed optically to identify the most appropriate electrode combinations to fit the fill-level change best. An algorithm was developed to choose suitable 'essential' electrode combinations for adaptive spatial resolution refinement. In the end, 28 capacitance measurements were needed to observe the sloshing in a coarse way, followed by 56 measurements for resolution enhancement. The straightforward approach based on the 16 elementary electrodes would have required 120 measurements. It is also shown that the resolution enhancement using the 56 electrode combinations can determine the fill level more accurately than the standard approach using the information from all 120 electrode combinations.</description><identifier>ISSN: 0957-0233</identifier><identifier>EISSN: 1361-6501</identifier><identifier>DOI: 10.1088/1361-6501/ab0486</identifier><identifier>CODEN: MSTCEP</identifier><language>eng</language><publisher>IOP Publishing</publisher><subject>adaptivity ; capacitance ; configurable ; ECT ; electrodes ; fill-level ; resolution</subject><ispartof>Measurement science &amp; technology, 2019-04, Vol.30 (4), p.45101</ispartof><rights>2019 IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3</citedby><cites>FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3</cites><orcidid>0000-0001-8092-2088</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Kandlbinder-Paret, Christoph</creatorcontrib><creatorcontrib>Fischerauer, Alice</creatorcontrib><creatorcontrib>Fischerauer, Gerhard</creatorcontrib><title>Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement</title><title>Measurement science &amp; technology</title><addtitle>MST</addtitle><addtitle>Meas. Sci. Technol</addtitle><description>It is of crucial interest to observe fluids and measure their properties in the field of process engineering. Capacitive measurement techniques have the advantage of being low-cost and having the ability to distinguish between higher-permittivity liquids such as water and gases such as air. A possible application for this technique is the non-invasive and non-intrusive determination of the water fill level in a pipe. In this paper we report on the design, implementation, and test of such a capacitive measurement system and on the finite element (FE) modeling of the system and typical application cases. The system consists of electrodes that are mounted around the circumference of a polycarbonate pipe. These elementary electrodes can be combined electronically via software to form larger 'synthetic' electrodes. The capacitances between the electrodes are measured to obtain information about the phase distribution inside the pipe (liquid or gaseous). While the spatial resolution depends on the size of the configurable electrodes, it is possible to first obtain coarse fill level information with larger electrodes and then obtain refined spatial resolution with a small-electrode configuration in a smaller region of interest. The disadvantage of using smaller electrodes is that the measurement time increases. The system was tested on a test bench with a pipe in which the liquid could be made to slosh by axial movements. The results of capacitance measurements in a 16-electrode system were compared to FE simulation results in Ansys. The results of the simulation were used to create a characteristic curve for the fill level as a function of the capacitance of every electrode combination. The fill level change was also observed optically to identify the most appropriate electrode combinations to fit the fill-level change best. An algorithm was developed to choose suitable 'essential' electrode combinations for adaptive spatial resolution refinement. In the end, 28 capacitance measurements were needed to observe the sloshing in a coarse way, followed by 56 measurements for resolution enhancement. The straightforward approach based on the 16 elementary electrodes would have required 120 measurements. It is also shown that the resolution enhancement using the 56 electrode combinations can determine the fill level more accurately than the standard approach using the information from all 120 electrode combinations.</description><subject>adaptivity</subject><subject>capacitance</subject><subject>configurable</subject><subject>ECT</subject><subject>electrodes</subject><subject>fill-level</subject><subject>resolution</subject><issn>0957-0233</issn><issn>1361-6501</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7ePebmxbqTpl85yuKqsOBFzyFNJrtZ2qYkrbL_3pYVT-JpYHifl5mHkFsGDwyqasV4wZIiB7ZSNWRVcUYWv6tzsgCRlwmknF-SqxgPAFCCEAsSN65pkgY_saEtqjgGbLEb6Bhdt6Na9Uq7QXUaacQu-hDplxv2VBnVD26CjlT7zrrdGFTdIMUG9RC8wUitDzRg9M04ON9R7PZzzVx-TS6saiLe_Mwl-dg8va9fku3b8-v6cZtonokhKbMCKmO5ghREyiwXRVVXCoS1eSYKlaa2rHNAFCbjxhpdlVlZC60m0Ojc8CWBU68OPsaAVvbBtSocJQM5S5OzITkbkidpE3J_Qpzv5cGPoZsO_C9-90e8jYPkIDMJWc6mcD898Q0p-H4a</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Kandlbinder-Paret, Christoph</creator><creator>Fischerauer, Alice</creator><creator>Fischerauer, Gerhard</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8092-2088</orcidid></search><sort><creationdate>20190401</creationdate><title>Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement</title><author>Kandlbinder-Paret, Christoph ; Fischerauer, Alice ; Fischerauer, Gerhard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>adaptivity</topic><topic>capacitance</topic><topic>configurable</topic><topic>ECT</topic><topic>electrodes</topic><topic>fill-level</topic><topic>resolution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kandlbinder-Paret, Christoph</creatorcontrib><creatorcontrib>Fischerauer, Alice</creatorcontrib><creatorcontrib>Fischerauer, Gerhard</creatorcontrib><collection>CrossRef</collection><jtitle>Measurement science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kandlbinder-Paret, Christoph</au><au>Fischerauer, Alice</au><au>Fischerauer, Gerhard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement</atitle><jtitle>Measurement science &amp; technology</jtitle><stitle>MST</stitle><addtitle>Meas. Sci. Technol</addtitle><date>2019-04-01</date><risdate>2019</risdate><volume>30</volume><issue>4</issue><spage>45101</spage><pages>45101-</pages><issn>0957-0233</issn><eissn>1361-6501</eissn><coden>MSTCEP</coden><abstract>It is of crucial interest to observe fluids and measure their properties in the field of process engineering. Capacitive measurement techniques have the advantage of being low-cost and having the ability to distinguish between higher-permittivity liquids such as water and gases such as air. A possible application for this technique is the non-invasive and non-intrusive determination of the water fill level in a pipe. In this paper we report on the design, implementation, and test of such a capacitive measurement system and on the finite element (FE) modeling of the system and typical application cases. The system consists of electrodes that are mounted around the circumference of a polycarbonate pipe. These elementary electrodes can be combined electronically via software to form larger 'synthetic' electrodes. The capacitances between the electrodes are measured to obtain information about the phase distribution inside the pipe (liquid or gaseous). While the spatial resolution depends on the size of the configurable electrodes, it is possible to first obtain coarse fill level information with larger electrodes and then obtain refined spatial resolution with a small-electrode configuration in a smaller region of interest. The disadvantage of using smaller electrodes is that the measurement time increases. The system was tested on a test bench with a pipe in which the liquid could be made to slosh by axial movements. The results of capacitance measurements in a 16-electrode system were compared to FE simulation results in Ansys. The results of the simulation were used to create a characteristic curve for the fill level as a function of the capacitance of every electrode combination. The fill level change was also observed optically to identify the most appropriate electrode combinations to fit the fill-level change best. An algorithm was developed to choose suitable 'essential' electrode combinations for adaptive spatial resolution refinement. In the end, 28 capacitance measurements were needed to observe the sloshing in a coarse way, followed by 56 measurements for resolution enhancement. The straightforward approach based on the 16 elementary electrodes would have required 120 measurements. It is also shown that the resolution enhancement using the 56 electrode combinations can determine the fill level more accurately than the standard approach using the information from all 120 electrode combinations.</abstract><pub>IOP Publishing</pub><doi>10.1088/1361-6501/ab0486</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8092-2088</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0957-0233
ispartof Measurement science & technology, 2019-04, Vol.30 (4), p.45101
issn 0957-0233
1361-6501
language eng
recordid cdi_iop_journals_10_1088_1361_6501_ab0486
source Institute of Physics
subjects adaptivity
capacitance
configurable
ECT
electrodes
fill-level
resolution
title Fill-level measurement using capacitance sensors with adaptively configurable electrodes for resolution enhancement
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A50%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fill-level%20measurement%20using%20capacitance%20sensors%20with%20adaptively%20configurable%20electrodes%20for%20resolution%20enhancement&rft.jtitle=Measurement%20science%20&%20technology&rft.au=Kandlbinder-Paret,%20Christoph&rft.date=2019-04-01&rft.volume=30&rft.issue=4&rft.spage=45101&rft.pages=45101-&rft.issn=0957-0233&rft.eissn=1361-6501&rft.coden=MSTCEP&rft_id=info:doi/10.1088/1361-6501/ab0486&rft_dat=%3Ciop_cross%3Emstab0486%3C/iop_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c349t-74608df3a020921f3968b8a09ff5496a22f7b50ee9d43dfdc8747b9ca746dc5d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true