Loading…

Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation

Effective early treatment-within 3-5 months of disease onset-significantly improves rheumatoid arthritis (RA) prognosis. Nevertheless, 1 in 3 patients experiences treatment failure which takes 3-6 months to detect with current monitoring techniques. The aim of this work is to develop a method for ex...

Full description

Saved in:
Bibliographic Details
Published in:Physics in medicine & biology 2024-06, Vol.69 (12)
Main Authors: Ioussoufovitch, S, Diop, M
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c300t-db9b49e2f8ec1611577860368df6419525697d914cc747ea625bdd4bc7612fc43
cites
container_end_page
container_issue 12
container_start_page
container_title Physics in medicine & biology
container_volume 69
creator Ioussoufovitch, S
Diop, M
description Effective early treatment-within 3-5 months of disease onset-significantly improves rheumatoid arthritis (RA) prognosis. Nevertheless, 1 in 3 patients experiences treatment failure which takes 3-6 months to detect with current monitoring techniques. The aim of this work is to develop a method for extracting quantitative features from data obtained with time-domain diffuse optical imaging (TD-DOI), and demonstrate their sensitivity to RA disease activity. 80 virtual phantoms of the proximal interphalangeal joint-obtained from a realistic tissue distribution derived from magnetic resonance imaging-were created to simulate RA-induced alterations in 5 physiological parameters. TD-DOI images were generated using Monte Carlo simulations, and Poisson noise was added to each image. Subsequently, each image was convolved with an instrument response function (IRF) to mimic experimental measurements. Various spatiotemporal features were extracted from the images (i.e. statistical moments, temporal Fourier components), corrected for IRF effects, and correlated with the disease index (DI) of each phantom. Spatiotemporal Fourier components of TD-DOI images were highly correlated with DI despite the confounding effects of noise and the IRF. Moreover, lower temporal frequency components (⩽0.4 GHz) demonstrated greater sensitivity to small changes in disease activity than previously published spatial features extracted from the same images. Spatiotemporal components of TD-DOI images may be more sensitive to small changes in RA disease activity than previously reported DOI features. TD-DOI may enable earlier detection of RA treatment failure, which would reduce the time needed to identify treatment failure and improve patient prognosis.
doi_str_mv 10.1088/1361-6560/ad539f
format article
fullrecord <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_iop_journals_10_1088_1361_6560_ad539f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3064581178</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-db9b49e2f8ec1611577860368df6419525697d914cc747ea625bdd4bc7612fc43</originalsourceid><addsrcrecordid>eNpVkU1rFTEUhoNY7LW6dyVZuujYZDLJZNxJsSoU3LTrkMlH7ymTZEwyF_o__MHmcqsiHDhwzsN7Pl6E3lHykRIprygTtBNckCttOZv8C7T7W3qJdoQw2k2U83P0upRHQiiV_fAKnTMpGWGC7dCvOwiusyloiNiC91txOK0VjF4wBP0A8QFXZ_YRfm4O-5RxSBFqysdG3rst6JrAYp3rPkOF0lSK001FmwoHqE-fcN27lN1J07qDW9IaXKxYR4vb2AILmIQPegGrK6T4Bp15vRT39jlfoPubL3fX37rbH1-_X3--7QwjpHZ2nuZhcr2XzlBBKR9HKdpZ0nox0In3XEyjnehgzDiMTouez9YOsxkF7b0Z2AX6cNJdc2rXlaoCFOOWRUeXtqIYEQOXlI6yoe-f0W0Ozqo1t-fkJ_Xnkw24PAGQVvWYthzb5ooSdTRKHV1RR1fUyah_o__D1zArMSnat-Ck79VqPfsNPD2UjA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3064581178</pqid></control><display><type>article</type><title>Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Ioussoufovitch, S ; Diop, M</creator><creatorcontrib>Ioussoufovitch, S ; Diop, M</creatorcontrib><description>Effective early treatment-within 3-5 months of disease onset-significantly improves rheumatoid arthritis (RA) prognosis. Nevertheless, 1 in 3 patients experiences treatment failure which takes 3-6 months to detect with current monitoring techniques. The aim of this work is to develop a method for extracting quantitative features from data obtained with time-domain diffuse optical imaging (TD-DOI), and demonstrate their sensitivity to RA disease activity. 80 virtual phantoms of the proximal interphalangeal joint-obtained from a realistic tissue distribution derived from magnetic resonance imaging-were created to simulate RA-induced alterations in 5 physiological parameters. TD-DOI images were generated using Monte Carlo simulations, and Poisson noise was added to each image. Subsequently, each image was convolved with an instrument response function (IRF) to mimic experimental measurements. Various spatiotemporal features were extracted from the images (i.e. statistical moments, temporal Fourier components), corrected for IRF effects, and correlated with the disease index (DI) of each phantom. Spatiotemporal Fourier components of TD-DOI images were highly correlated with DI despite the confounding effects of noise and the IRF. Moreover, lower temporal frequency components (⩽0.4 GHz) demonstrated greater sensitivity to small changes in disease activity than previously published spatial features extracted from the same images. Spatiotemporal components of TD-DOI images may be more sensitive to small changes in RA disease activity than previously reported DOI features. TD-DOI may enable earlier detection of RA treatment failure, which would reduce the time needed to identify treatment failure and improve patient prognosis.</description><identifier>ISSN: 0031-9155</identifier><identifier>ISSN: 1361-6560</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ad539f</identifier><identifier>PMID: 38830363</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Arthritis, Rheumatoid - diagnostic imaging ; Computer Simulation ; diffuse optical imaging ; Humans ; Image Processing, Computer-Assisted - methods ; Monte Carlo Method ; Monte Carlo simulation ; near-infrared ; Optical Imaging - methods ; Phantoms, Imaging ; rheumatoid arthritis ; Time Factors ; time-domain</subject><ispartof>Physics in medicine &amp; biology, 2024-06, Vol.69 (12)</ispartof><rights>2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd</rights><rights>Creative Commons Attribution license.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c300t-db9b49e2f8ec1611577860368df6419525697d914cc747ea625bdd4bc7612fc43</citedby><orcidid>0000-0001-8077-4847</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38830363$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ioussoufovitch, S</creatorcontrib><creatorcontrib>Diop, M</creatorcontrib><title>Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>Effective early treatment-within 3-5 months of disease onset-significantly improves rheumatoid arthritis (RA) prognosis. Nevertheless, 1 in 3 patients experiences treatment failure which takes 3-6 months to detect with current monitoring techniques. The aim of this work is to develop a method for extracting quantitative features from data obtained with time-domain diffuse optical imaging (TD-DOI), and demonstrate their sensitivity to RA disease activity. 80 virtual phantoms of the proximal interphalangeal joint-obtained from a realistic tissue distribution derived from magnetic resonance imaging-were created to simulate RA-induced alterations in 5 physiological parameters. TD-DOI images were generated using Monte Carlo simulations, and Poisson noise was added to each image. Subsequently, each image was convolved with an instrument response function (IRF) to mimic experimental measurements. Various spatiotemporal features were extracted from the images (i.e. statistical moments, temporal Fourier components), corrected for IRF effects, and correlated with the disease index (DI) of each phantom. Spatiotemporal Fourier components of TD-DOI images were highly correlated with DI despite the confounding effects of noise and the IRF. Moreover, lower temporal frequency components (⩽0.4 GHz) demonstrated greater sensitivity to small changes in disease activity than previously published spatial features extracted from the same images. Spatiotemporal components of TD-DOI images may be more sensitive to small changes in RA disease activity than previously reported DOI features. TD-DOI may enable earlier detection of RA treatment failure, which would reduce the time needed to identify treatment failure and improve patient prognosis.</description><subject>Arthritis, Rheumatoid - diagnostic imaging</subject><subject>Computer Simulation</subject><subject>diffuse optical imaging</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo simulation</subject><subject>near-infrared</subject><subject>Optical Imaging - methods</subject><subject>Phantoms, Imaging</subject><subject>rheumatoid arthritis</subject><subject>Time Factors</subject><subject>time-domain</subject><issn>0031-9155</issn><issn>1361-6560</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpVkU1rFTEUhoNY7LW6dyVZuujYZDLJZNxJsSoU3LTrkMlH7ymTZEwyF_o__MHmcqsiHDhwzsN7Pl6E3lHykRIprygTtBNckCttOZv8C7T7W3qJdoQw2k2U83P0upRHQiiV_fAKnTMpGWGC7dCvOwiusyloiNiC91txOK0VjF4wBP0A8QFXZ_YRfm4O-5RxSBFqysdG3rst6JrAYp3rPkOF0lSK001FmwoHqE-fcN27lN1J07qDW9IaXKxYR4vb2AILmIQPegGrK6T4Bp15vRT39jlfoPubL3fX37rbH1-_X3--7QwjpHZ2nuZhcr2XzlBBKR9HKdpZ0nox0In3XEyjnehgzDiMTouez9YOsxkF7b0Z2AX6cNJdc2rXlaoCFOOWRUeXtqIYEQOXlI6yoe-f0W0Ozqo1t-fkJ_Xnkw24PAGQVvWYthzb5ooSdTRKHV1RR1fUyah_o__D1zArMSnat-Ck79VqPfsNPD2UjA</recordid><startdate>20240613</startdate><enddate>20240613</enddate><creator>Ioussoufovitch, S</creator><creator>Diop, M</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8077-4847</orcidid></search><sort><creationdate>20240613</creationdate><title>Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation</title><author>Ioussoufovitch, S ; Diop, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-db9b49e2f8ec1611577860368df6419525697d914cc747ea625bdd4bc7612fc43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Arthritis, Rheumatoid - diagnostic imaging</topic><topic>Computer Simulation</topic><topic>diffuse optical imaging</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo simulation</topic><topic>near-infrared</topic><topic>Optical Imaging - methods</topic><topic>Phantoms, Imaging</topic><topic>rheumatoid arthritis</topic><topic>Time Factors</topic><topic>time-domain</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ioussoufovitch, S</creatorcontrib><creatorcontrib>Diop, M</creatorcontrib><collection>Open Access: IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ioussoufovitch, S</au><au>Diop, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2024-06-13</date><risdate>2024</risdate><volume>69</volume><issue>12</issue><issn>0031-9155</issn><issn>1361-6560</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>Effective early treatment-within 3-5 months of disease onset-significantly improves rheumatoid arthritis (RA) prognosis. Nevertheless, 1 in 3 patients experiences treatment failure which takes 3-6 months to detect with current monitoring techniques. The aim of this work is to develop a method for extracting quantitative features from data obtained with time-domain diffuse optical imaging (TD-DOI), and demonstrate their sensitivity to RA disease activity. 80 virtual phantoms of the proximal interphalangeal joint-obtained from a realistic tissue distribution derived from magnetic resonance imaging-were created to simulate RA-induced alterations in 5 physiological parameters. TD-DOI images were generated using Monte Carlo simulations, and Poisson noise was added to each image. Subsequently, each image was convolved with an instrument response function (IRF) to mimic experimental measurements. Various spatiotemporal features were extracted from the images (i.e. statistical moments, temporal Fourier components), corrected for IRF effects, and correlated with the disease index (DI) of each phantom. Spatiotemporal Fourier components of TD-DOI images were highly correlated with DI despite the confounding effects of noise and the IRF. Moreover, lower temporal frequency components (⩽0.4 GHz) demonstrated greater sensitivity to small changes in disease activity than previously published spatial features extracted from the same images. Spatiotemporal components of TD-DOI images may be more sensitive to small changes in RA disease activity than previously reported DOI features. TD-DOI may enable earlier detection of RA treatment failure, which would reduce the time needed to identify treatment failure and improve patient prognosis.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>38830363</pmid><doi>10.1088/1361-6560/ad539f</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0001-8077-4847</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2024-06, Vol.69 (12)
issn 0031-9155
1361-6560
1361-6560
language eng
recordid cdi_iop_journals_10_1088_1361_6560_ad539f
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
subjects Arthritis, Rheumatoid - diagnostic imaging
Computer Simulation
diffuse optical imaging
Humans
Image Processing, Computer-Assisted - methods
Monte Carlo Method
Monte Carlo simulation
near-infrared
Optical Imaging - methods
Phantoms, Imaging
rheumatoid arthritis
Time Factors
time-domain
title Time-domain diffuse optical imaging technique for monitoring rheumatoid arthritis disease activity: theoretical development and in silico validation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T06%3A39%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Time-domain%20diffuse%20optical%20imaging%20technique%20for%20monitoring%20rheumatoid%20arthritis%20disease%20activity:%20theoretical%20development%20and%20in%20silico%20validation&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Ioussoufovitch,%20S&rft.date=2024-06-13&rft.volume=69&rft.issue=12&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ad539f&rft_dat=%3Cproquest_iop_j%3E3064581178%3C/proquest_iop_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c300t-db9b49e2f8ec1611577860368df6419525697d914cc747ea625bdd4bc7612fc43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3064581178&rft_id=info:pmid/38830363&rfr_iscdi=true