Loading…

Design and testing of fluid resistor for repetitive high-voltage pulse generator

The paper presents a design and the results of testing of the liquid resistive load for a repetitive high-voltage generator (200 kV, 0.5 ms). The load uses a sealed dielectric case, which is to be placed into a vacuum volume (5×10-4 Torr) for electrical strength ensuring. Repetitive testing of the g...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2017-05, Vol.830 (1), p.12047
Main Authors: Poloskov, A V, Egorov, I S, Serebrennikov, M A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The paper presents a design and the results of testing of the liquid resistive load for a repetitive high-voltage generator (200 kV, 0.5 ms). The load uses a sealed dielectric case, which is to be placed into a vacuum volume (5×10-4 Torr) for electrical strength ensuring. Repetitive testing of the generator with the load (10 pps) caused the electrolyte heating, the load resistance decreasing, and the changing of a generator mode. An expansion tank is used to compensate thermal expansion of the electrolyte, which makes it possible to absorb up to 1 MJ of energy in the load without seals breaking. A generator load curve can be obtained for one experiment with a help of the fluid load without any additional depressurization of the vacuum volume.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/830/1/012047