Loading…
Design and testing of fluid resistor for repetitive high-voltage pulse generator
The paper presents a design and the results of testing of the liquid resistive load for a repetitive high-voltage generator (200 kV, 0.5 ms). The load uses a sealed dielectric case, which is to be placed into a vacuum volume (5×10-4 Torr) for electrical strength ensuring. Repetitive testing of the g...
Saved in:
Published in: | Journal of physics. Conference series 2017-05, Vol.830 (1), p.12047 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The paper presents a design and the results of testing of the liquid resistive load for a repetitive high-voltage generator (200 kV, 0.5 ms). The load uses a sealed dielectric case, which is to be placed into a vacuum volume (5×10-4 Torr) for electrical strength ensuring. Repetitive testing of the generator with the load (10 pps) caused the electrolyte heating, the load resistance decreasing, and the changing of a generator mode. An expansion tank is used to compensate thermal expansion of the electrolyte, which makes it possible to absorb up to 1 MJ of energy in the load without seals breaking. A generator load curve can be obtained for one experiment with a help of the fluid load without any additional depressurization of the vacuum volume. |
---|---|
ISSN: | 1742-6588 1742-6596 |
DOI: | 10.1088/1742-6596/830/1/012047 |