Loading…
Empirical Formula for Minimum Miscible Pressure of CO2-oil System in China
MMP of CO2 and system in China oilfields is generally higher than that of other oilfields aboard. By abundant investigations the reason and the prediction of MMP is systematic analyzed. Based on the statistical data of reservoir characteristics, oil physical properties, injection gas components from...
Saved in:
Published in: | IOP conference series. Earth and environmental science 2018-01, Vol.108 (3) |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | MMP of CO2 and system in China oilfields is generally higher than that of other oilfields aboard. By abundant investigations the reason and the prediction of MMP is systematic analyzed. Based on the statistical data of reservoir characteristics, oil physical properties, injection gas components from dozens of oilfields in China, a correlation formula was regressed and derived. Compared to some other empirical formula, predicting results of this new empirical formula is relatively satisfactory. |
---|---|
ISSN: | 1755-1307 1755-1315 |
DOI: | 10.1088/1755-1315/108/3/032047 |