Loading…

Experimental Study on Seismic Performance of Prefabricated Joints of Underground Utility Tunnel

In order to study the seismic performance of underground utility tunnel prefabricated joints anchored by button-head reinforcement, pseudo-static tests were carried out on two full-scale underground utility tunnel prefabricated joint specimens. The failure mode, bearing capacity, energy dissipation,...

Full description

Saved in:
Bibliographic Details
Published in:IOP conference series. Earth and environmental science 2019-05, Vol.267 (4), p.42109
Main Authors: Hu, Yaoxing, Li, Zhengying, He, Jijun, Huang, Zulin
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In order to study the seismic performance of underground utility tunnel prefabricated joints anchored by button-head reinforcement, pseudo-static tests were carried out on two full-scale underground utility tunnel prefabricated joint specimens. The failure mode, bearing capacity, energy dissipation, and other seismic performance of the joints were analyzed. The results show that the bearing capacity, energy dissipation and other seismic performance parameter of these specimens can meet the seismic design requirements. However, the damage in the core area of the joint is severe under the pseudo-static loading. Therefore, when the button-head reinforcement is applied to practical engineering, necessary reinforcement measures should be taken to ensure that the joint has good seismic performance.
ISSN:1755-1307
1755-1315
DOI:10.1088/1755-1315/267/4/042109