Loading…

Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance

Misalignment in the flow field plates of High-Temperature Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) due to manufacturing tolerances, assembly process, or unavoidable vibration during the cell operation is contemplated its performance and durability. This study investigates the effect of flow...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the Electrochemical Society 2022-12, Vol.169 (12), p.124508
Main Authors: K. P., Venkatesh Babu, Varghese, Geethu, Joseph, Thadathil Varghese, Chippar, Purushothama
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3
cites cdi_FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3
container_end_page
container_issue 12
container_start_page 124508
container_title Journal of the Electrochemical Society
container_volume 169
creator K. P., Venkatesh Babu
Varghese, Geethu
Joseph, Thadathil Varghese
Chippar, Purushothama
description Misalignment in the flow field plates of High-Temperature Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) due to manufacturing tolerances, assembly process, or unavoidable vibration during the cell operation is contemplated its performance and durability. This study investigates the effect of flow field plate misalignment and its concomitant impact with varying the clamping pressures on HT-PEMFC operation. The study considers six degrees of cathode flow field misalignment, varying from 0% to 100% with respect to the anode flow field. Clamping pressures ranging from 1 to 2 MPa are applied to the various cases of misalignment to study their effect on GDL deformation and intrusion into the channels. The structural analysis shows that as the misalignment increases from 0 to 100%, the GDL compression increases from 26.72% to 37.75% for 1 MPa, 40.07% to 56.63% for 1.5 MPa, and 53.43% to 75.51% for 2 MPa, owing to the increase in compression approximately by 41% from their base cases and it is also crucial to note that GDL compression exaggerates at higher clamping pressures. The misalignment results in the sagging of Membrane Electrode Assembly (MEA), and the amplitude of wave nature is proportional to the degree of misalignment and clamping pressure, indicating the misalignment is the sole factor for structural changes. As a result, considerable variance in current distribution and average value is observed, i.e., at operating voltage 0.5 V, the current density drops from 4472.7 to 4264.4, 4420.7 to 4211.8, and 4374.1 to 4161.3 A m −2 from cases 1 to 6 for clamping pressures 1, 1.5, and 2 MPa, respectively, resulting in a 4.7% loss in performance. According to the observations, a misalignment of 60% is tolerable, with minimal performance loss and negligible non-uniformity in cell distributions. Combined effect of flow field misalignment and assembly force on cell is studied. The HT-PEMFC structure and performance were affected by flow field misalignment. MEA sags in direct proportion to the degree of misalignment and clamping pressure. Reactant and current distributions alter as a result of structural modifications. According to research, a 60 percent misalignment tolerance is acceptable.
doi_str_mv 10.1149/1945-7111/aca834
format article
fullrecord <record><control><sourceid>iop_cross</sourceid><recordid>TN_cdi_iop_journals_10_1149_1945_7111_aca834</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>jesaca834</sourcerecordid><originalsourceid>FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3</originalsourceid><addsrcrecordid>eNp1UMtOwzAQtBBIlMKd434AoXbitMkRlb6kVvRQztHGWZdUTlzZqVBv_APfwI_xJbgq4oa00mpnd2ZWw9i94I9CyHwgcplGIyHEABVmibxgvT_okvU4F0kkh6m4Zjfe78IoMjnqsa9F29HWYUcVTLQm1YHVMDX2HaY1mQpWtUdTb9uG2g6wrWCGHp5rrQ--ti0s8UgOxrbZO_InZBAE3XkXal5v32BDzZ6CxcERfH98wtqaYxNYExPsXBg6ghU1pcOWYHogA2MyBtbktHUNtopu2ZVG4-nut_fZ63SyGc-j5ctsMX5aRirOeBdRprHKpU5jroaSx4mKU6wqzEa65LEWQ1SJJFIk9TBPlahGsSwFlkRpimWOSZ_xs65y1ntHuti7ukF3LAQvTjEXp0yLU6bFOeZAeThTarsvdvbg2vDg_-c_NsiDqg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>K. P., Venkatesh Babu ; Varghese, Geethu ; Joseph, Thadathil Varghese ; Chippar, Purushothama</creator><creatorcontrib>K. P., Venkatesh Babu ; Varghese, Geethu ; Joseph, Thadathil Varghese ; Chippar, Purushothama</creatorcontrib><description>Misalignment in the flow field plates of High-Temperature Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) due to manufacturing tolerances, assembly process, or unavoidable vibration during the cell operation is contemplated its performance and durability. This study investigates the effect of flow field plate misalignment and its concomitant impact with varying the clamping pressures on HT-PEMFC operation. The study considers six degrees of cathode flow field misalignment, varying from 0% to 100% with respect to the anode flow field. Clamping pressures ranging from 1 to 2 MPa are applied to the various cases of misalignment to study their effect on GDL deformation and intrusion into the channels. The structural analysis shows that as the misalignment increases from 0 to 100%, the GDL compression increases from 26.72% to 37.75% for 1 MPa, 40.07% to 56.63% for 1.5 MPa, and 53.43% to 75.51% for 2 MPa, owing to the increase in compression approximately by 41% from their base cases and it is also crucial to note that GDL compression exaggerates at higher clamping pressures. The misalignment results in the sagging of Membrane Electrode Assembly (MEA), and the amplitude of wave nature is proportional to the degree of misalignment and clamping pressure, indicating the misalignment is the sole factor for structural changes. As a result, considerable variance in current distribution and average value is observed, i.e., at operating voltage 0.5 V, the current density drops from 4472.7 to 4264.4, 4420.7 to 4211.8, and 4374.1 to 4161.3 A m −2 from cases 1 to 6 for clamping pressures 1, 1.5, and 2 MPa, respectively, resulting in a 4.7% loss in performance. According to the observations, a misalignment of 60% is tolerable, with minimal performance loss and negligible non-uniformity in cell distributions. Combined effect of flow field misalignment and assembly force on cell is studied. The HT-PEMFC structure and performance were affected by flow field misalignment. MEA sags in direct proportion to the degree of misalignment and clamping pressure. Reactant and current distributions alter as a result of structural modifications. According to research, a 60 percent misalignment tolerance is acceptable.</description><identifier>ISSN: 0013-4651</identifier><identifier>EISSN: 1945-7111</identifier><identifier>DOI: 10.1149/1945-7111/aca834</identifier><identifier>CODEN: JESOAN</identifier><language>eng</language><publisher>IOP Publishing</publisher><ispartof>Journal of the Electrochemical Society, 2022-12, Vol.169 (12), p.124508</ispartof><rights>2022 The Electrochemical Society (“ECS”). Published on behalf of ECS by IOP Publishing Limited</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3</citedby><cites>FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3</cites><orcidid>0000-0002-3255-680X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>K. P., Venkatesh Babu</creatorcontrib><creatorcontrib>Varghese, Geethu</creatorcontrib><creatorcontrib>Joseph, Thadathil Varghese</creatorcontrib><creatorcontrib>Chippar, Purushothama</creatorcontrib><title>Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance</title><title>Journal of the Electrochemical Society</title><addtitle>JES</addtitle><addtitle>J. Electrochem. Soc</addtitle><description>Misalignment in the flow field plates of High-Temperature Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) due to manufacturing tolerances, assembly process, or unavoidable vibration during the cell operation is contemplated its performance and durability. This study investigates the effect of flow field plate misalignment and its concomitant impact with varying the clamping pressures on HT-PEMFC operation. The study considers six degrees of cathode flow field misalignment, varying from 0% to 100% with respect to the anode flow field. Clamping pressures ranging from 1 to 2 MPa are applied to the various cases of misalignment to study their effect on GDL deformation and intrusion into the channels. The structural analysis shows that as the misalignment increases from 0 to 100%, the GDL compression increases from 26.72% to 37.75% for 1 MPa, 40.07% to 56.63% for 1.5 MPa, and 53.43% to 75.51% for 2 MPa, owing to the increase in compression approximately by 41% from their base cases and it is also crucial to note that GDL compression exaggerates at higher clamping pressures. The misalignment results in the sagging of Membrane Electrode Assembly (MEA), and the amplitude of wave nature is proportional to the degree of misalignment and clamping pressure, indicating the misalignment is the sole factor for structural changes. As a result, considerable variance in current distribution and average value is observed, i.e., at operating voltage 0.5 V, the current density drops from 4472.7 to 4264.4, 4420.7 to 4211.8, and 4374.1 to 4161.3 A m −2 from cases 1 to 6 for clamping pressures 1, 1.5, and 2 MPa, respectively, resulting in a 4.7% loss in performance. According to the observations, a misalignment of 60% is tolerable, with minimal performance loss and negligible non-uniformity in cell distributions. Combined effect of flow field misalignment and assembly force on cell is studied. The HT-PEMFC structure and performance were affected by flow field misalignment. MEA sags in direct proportion to the degree of misalignment and clamping pressure. Reactant and current distributions alter as a result of structural modifications. According to research, a 60 percent misalignment tolerance is acceptable.</description><issn>0013-4651</issn><issn>1945-7111</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1UMtOwzAQtBBIlMKd434AoXbitMkRlb6kVvRQztHGWZdUTlzZqVBv_APfwI_xJbgq4oa00mpnd2ZWw9i94I9CyHwgcplGIyHEABVmibxgvT_okvU4F0kkh6m4Zjfe78IoMjnqsa9F29HWYUcVTLQm1YHVMDX2HaY1mQpWtUdTb9uG2g6wrWCGHp5rrQ--ti0s8UgOxrbZO_InZBAE3XkXal5v32BDzZ6CxcERfH98wtqaYxNYExPsXBg6ghU1pcOWYHogA2MyBtbktHUNtopu2ZVG4-nut_fZ63SyGc-j5ctsMX5aRirOeBdRprHKpU5jroaSx4mKU6wqzEa65LEWQ1SJJFIk9TBPlahGsSwFlkRpimWOSZ_xs65y1ntHuti7ukF3LAQvTjEXp0yLU6bFOeZAeThTarsvdvbg2vDg_-c_NsiDqg</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>K. P., Venkatesh Babu</creator><creator>Varghese, Geethu</creator><creator>Joseph, Thadathil Varghese</creator><creator>Chippar, Purushothama</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-3255-680X</orcidid></search><sort><creationdate>20221201</creationdate><title>Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance</title><author>K. P., Venkatesh Babu ; Varghese, Geethu ; Joseph, Thadathil Varghese ; Chippar, Purushothama</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>K. P., Venkatesh Babu</creatorcontrib><creatorcontrib>Varghese, Geethu</creatorcontrib><creatorcontrib>Joseph, Thadathil Varghese</creatorcontrib><creatorcontrib>Chippar, Purushothama</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of the Electrochemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>K. P., Venkatesh Babu</au><au>Varghese, Geethu</au><au>Joseph, Thadathil Varghese</au><au>Chippar, Purushothama</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance</atitle><jtitle>Journal of the Electrochemical Society</jtitle><stitle>JES</stitle><addtitle>J. Electrochem. Soc</addtitle><date>2022-12-01</date><risdate>2022</risdate><volume>169</volume><issue>12</issue><spage>124508</spage><pages>124508-</pages><issn>0013-4651</issn><eissn>1945-7111</eissn><coden>JESOAN</coden><abstract>Misalignment in the flow field plates of High-Temperature Polymer Electrolyte Membrane Fuel Cell (HT-PEMFC) due to manufacturing tolerances, assembly process, or unavoidable vibration during the cell operation is contemplated its performance and durability. This study investigates the effect of flow field plate misalignment and its concomitant impact with varying the clamping pressures on HT-PEMFC operation. The study considers six degrees of cathode flow field misalignment, varying from 0% to 100% with respect to the anode flow field. Clamping pressures ranging from 1 to 2 MPa are applied to the various cases of misalignment to study their effect on GDL deformation and intrusion into the channels. The structural analysis shows that as the misalignment increases from 0 to 100%, the GDL compression increases from 26.72% to 37.75% for 1 MPa, 40.07% to 56.63% for 1.5 MPa, and 53.43% to 75.51% for 2 MPa, owing to the increase in compression approximately by 41% from their base cases and it is also crucial to note that GDL compression exaggerates at higher clamping pressures. The misalignment results in the sagging of Membrane Electrode Assembly (MEA), and the amplitude of wave nature is proportional to the degree of misalignment and clamping pressure, indicating the misalignment is the sole factor for structural changes. As a result, considerable variance in current distribution and average value is observed, i.e., at operating voltage 0.5 V, the current density drops from 4472.7 to 4264.4, 4420.7 to 4211.8, and 4374.1 to 4161.3 A m −2 from cases 1 to 6 for clamping pressures 1, 1.5, and 2 MPa, respectively, resulting in a 4.7% loss in performance. According to the observations, a misalignment of 60% is tolerable, with minimal performance loss and negligible non-uniformity in cell distributions. Combined effect of flow field misalignment and assembly force on cell is studied. The HT-PEMFC structure and performance were affected by flow field misalignment. MEA sags in direct proportion to the degree of misalignment and clamping pressure. Reactant and current distributions alter as a result of structural modifications. According to research, a 60 percent misalignment tolerance is acceptable.</abstract><pub>IOP Publishing</pub><doi>10.1149/1945-7111/aca834</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0002-3255-680X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0013-4651
ispartof Journal of the Electrochemical Society, 2022-12, Vol.169 (12), p.124508
issn 0013-4651
1945-7111
language eng
recordid cdi_iop_journals_10_1149_1945_7111_aca834
source Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
title Integrated Effect of Flow Field Misalignment and Gas Diffusion Layer Compression/Intrusion on High Temperature – Polymer Electrolyte Membrane Fuel Cell Performance
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T09%3A16%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-iop_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Integrated%20Effect%20of%20Flow%20Field%20Misalignment%20and%20Gas%20Diffusion%20Layer%20Compression/Intrusion%20on%20High%20Temperature%20%E2%80%93%20Polymer%20Electrolyte%20Membrane%20Fuel%20Cell%20Performance&rft.jtitle=Journal%20of%20the%20Electrochemical%20Society&rft.au=K.%20P.,%20Venkatesh%20Babu&rft.date=2022-12-01&rft.volume=169&rft.issue=12&rft.spage=124508&rft.pages=124508-&rft.issn=0013-4651&rft.eissn=1945-7111&rft.coden=JESOAN&rft_id=info:doi/10.1149/1945-7111/aca834&rft_dat=%3Ciop_cross%3Ejesaca834%3C/iop_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c280t-e8fad94f520c64023c25adda87fb02f16ac34eece4f695c1d724b1abee55ab9a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true