Successive over-relaxation methods have been applied to solutions of Poisson's equation for temperature distribution analysis of a number of metal reinforced and metal cored thick film substrate models. These include aluminium and copper clad invar reinforced alumina as well as dielectric coate...

Full description

Saved in:
Bibliographic Details
Published in:Microelectronics international 1986-02, Vol.3 (2), p.65-67
Main Authors: Bilson, R.T, Allen, R.W, McCarthy, J.P, Stanley, A.J
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Successive over-relaxation methods have been applied to solutions of Poisson's equation for temperature distribution analysis of a number of metal reinforced and metal cored thick film substrate models. These include aluminium and copper clad invar reinforced alumina as well as dielectric coated steel and titanium substrates. The results of the computer analyses have been compared in some instances with actual measurements of temperature distributions in real structures. Some detailed inconsistencies have been found but good correlation has been shown in terms of ranked effectiveness.