Loading…

High-Resolution MicroPET Imaging of Carcino-Embryonic Antigen-Positive Xenografts by Using a Copper-64-Labeled Engineered Antibody Fragment

Rapid imaging by antitumor antibodies has been limited by the prolonged targeting kinetics and clerance of labeled whole antibodies. Genetically engineered fragments with rapid access and high retention in tumor tissue combined with rapid blood clearance are suitable for labeling with short-lived ra...

Full description

Saved in:
Bibliographic Details
Published in:Proceedings of the National Academy of Sciences - PNAS 2000-07, Vol.97 (15), p.8495-8500
Main Authors: Wu, Anna M., Yazaki, Paul J., Tsai, Shih-Wa, Nguyen, Khoi, Anderson, Anne-Line, McCarthy, Deborah W., Welch, Michael J., Shively, John E., Williams, Lawrence E., Raubitschek, Andrew A., Jeffrey Y. C. Wong, Toyokuni, Tatsushi, Phelps, Michael E., Gambhir, Sanjiv S.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Rapid imaging by antitumor antibodies has been limited by the prolonged targeting kinetics and clerance of labeled whole antibodies. Genetically engineered fragments with rapid access and high retention in tumor tissue combined with rapid blood clearance are suitable for labeling with short-lived radionuclides, including positron-emitting isotopes for positron-emission tomography (PET). An engineered fragment was developed from the high-affinity anticarcinoembryonic antigen (CEA) monoclonal antibody T84.66. This single-chain variable fragment (Fv)-CH3, or minibody, was produced as a bivalent 80 kDa dimer. The macrocyclic chelating agent 1,4,7, 10-tetraazacyclododecane-N,N′,N′ ′, N′ ′ ′-tetraacetic acid (DOTA) was conjugated to the anti-CEA minibody for labeling with copper-64, a positron-emitting radionuclide (t1/2= 12.7 h). In vivo distribution was evaluated in athymic mice bearing paired LS174T human colon carcinoma (CEA positive) and C6 rat glioma (CEA negative) xenografts. Five hours after injection with64Cu-DOTA-minibody, microPET imaging showed high uptake in CEA-positive tumor (17.9% injected dose per gram ± 3.79) compared with control tumor (6.0% injected dose per gram ± 1.0). In addition, significant uptake was seen in liver, with low uptake in other tissues. Average target/background ratios relative to neighboring tissue were 3-4:1. Engineered antibody fragments labeled with positron-emitting isotopes such as copper-64 provide a new class of agents for PET imaging of tumors.
ISSN:0027-8424
DOI:10.1073/pnas.150228297