A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems

An improved and fast version of a closed loop system for measuring net CO2 exchange rates (NCER) in the field using a portable infrared gas analyser (IRGA) is described. An electronic timer—differentiator device measures and displays very accurately the time period necessary to bridge over a constan...

Full description

Saved in:
Bibliographic Details
Published in:Journal of experimental botany 1986-08, Vol.37 (181), p.1234-1244
Main Authors: CEULEMANS, R., KOCKELBERGH, F., IMPENS, I.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1244
container_issue 181
container_start_page 1234
container_title Journal of experimental botany
container_volume 37
creator CEULEMANS, R.
KOCKELBERGH, F.
IMPENS, I.
description An improved and fast version of a closed loop system for measuring net CO2 exchange rates (NCER) in the field using a portable infrared gas analyser (IRGA) is described. An electronic timer—differentiator device measures and displays very accurately the time period necessary to bridge over a constant and preselected CO2 concentration difference. The time required for each measurement from start of the measurement to display of final results is c. 9 s for NCER of 24 μmol m—2 s—1. The measurement interval is sufficiently short that no environmental control in the perspex mini-cuvette is needed. Some satisfactory data of NCER measurements obtained under field and glasshouse conditions on poplar, sugar beet and winter wheat are presented.
format article
fullrecord <record><control><sourceid>jstor</sourceid><recordid>TN_cdi_jstor_primary_23688618</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>23688618</jstor_id><sourcerecordid>23688618</sourcerecordid><originalsourceid>FETCH-jstor_primary_236886183</originalsourceid><addsrcrecordid>eNqFitsKgkAURYcoyC6fEJwPSBjHS_YYU1JQFNVzMtQYijo2xwv-fSi997TYa68BMSzHoyZzbGtIDEoZM-naXY3JBDGhlLrUdQ3y2EAgsFzCUTXAFZYg8lc_LqqRGq7yU8U6zt-wlXX8lBApDYes0KruJE8Vyq5XBfAzO0mBVV_fWixlhjMyikSKcv7jlCyC3Z3vzQRLpcNCx5nQbchsz_c9y7f__V8akj99</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems</title><source>JSTOR Archival Journals and Primary Sources Collection</source><source>Oxford University Press Archive</source><creator>CEULEMANS, R. ; KOCKELBERGH, F. ; IMPENS, I.</creator><creatorcontrib>CEULEMANS, R. ; KOCKELBERGH, F. ; IMPENS, I.</creatorcontrib><description>An improved and fast version of a closed loop system for measuring net CO2 exchange rates (NCER) in the field using a portable infrared gas analyser (IRGA) is described. An electronic timer—differentiator device measures and displays very accurately the time period necessary to bridge over a constant and preselected CO2 concentration difference. The time required for each measurement from start of the measurement to display of final results is c. 9 s for NCER of 24 μmol m—2 s—1. The measurement interval is sufficiently short that no environmental control in the perspex mini-cuvette is needed. Some satisfactory data of NCER measurements obtained under field and glasshouse conditions on poplar, sugar beet and winter wheat are presented.</description><identifier>ISSN: 0022-0957</identifier><identifier>EISSN: 1460-2431</identifier><language>eng</language><publisher>Clarendon Press</publisher><subject>Carbon dioxide ; Closed loop systems ; Closed systems ; Flux density ; Photons ; Photosynthesis ; Plants ; Pumps ; Sugar beets ; Timing devices</subject><ispartof>Journal of experimental botany, 1986-08, Vol.37 (181), p.1234-1244</ispartof><rights>Oxford University Press 1986</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/23688618$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/23688618$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>314,780,784,58236,58469</link.rule.ids></links><search><creatorcontrib>CEULEMANS, R.</creatorcontrib><creatorcontrib>KOCKELBERGH, F.</creatorcontrib><creatorcontrib>IMPENS, I.</creatorcontrib><title>A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems</title><title>Journal of experimental botany</title><description>An improved and fast version of a closed loop system for measuring net CO2 exchange rates (NCER) in the field using a portable infrared gas analyser (IRGA) is described. An electronic timer—differentiator device measures and displays very accurately the time period necessary to bridge over a constant and preselected CO2 concentration difference. The time required for each measurement from start of the measurement to display of final results is c. 9 s for NCER of 24 μmol m—2 s—1. The measurement interval is sufficiently short that no environmental control in the perspex mini-cuvette is needed. Some satisfactory data of NCER measurements obtained under field and glasshouse conditions on poplar, sugar beet and winter wheat are presented.</description><subject>Carbon dioxide</subject><subject>Closed loop systems</subject><subject>Closed systems</subject><subject>Flux density</subject><subject>Photons</subject><subject>Photosynthesis</subject><subject>Plants</subject><subject>Pumps</subject><subject>Sugar beets</subject><subject>Timing devices</subject><issn>0022-0957</issn><issn>1460-2431</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1986</creationdate><recordtype>article</recordtype><sourceid/><recordid>eNqFitsKgkAURYcoyC6fEJwPSBjHS_YYU1JQFNVzMtQYijo2xwv-fSi997TYa68BMSzHoyZzbGtIDEoZM-naXY3JBDGhlLrUdQ3y2EAgsFzCUTXAFZYg8lc_LqqRGq7yU8U6zt-wlXX8lBApDYes0KruJE8Vyq5XBfAzO0mBVV_fWixlhjMyikSKcv7jlCyC3Z3vzQRLpcNCx5nQbchsz_c9y7f__V8akj99</recordid><startdate>19860801</startdate><enddate>19860801</enddate><creator>CEULEMANS, R.</creator><creator>KOCKELBERGH, F.</creator><creator>IMPENS, I.</creator><general>Clarendon Press</general><scope/></search><sort><creationdate>19860801</creationdate><title>A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems</title><author>CEULEMANS, R. ; KOCKELBERGH, F. ; IMPENS, I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-jstor_primary_236886183</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1986</creationdate><topic>Carbon dioxide</topic><topic>Closed loop systems</topic><topic>Closed systems</topic><topic>Flux density</topic><topic>Photons</topic><topic>Photosynthesis</topic><topic>Plants</topic><topic>Pumps</topic><topic>Sugar beets</topic><topic>Timing devices</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>CEULEMANS, R.</creatorcontrib><creatorcontrib>KOCKELBERGH, F.</creatorcontrib><creatorcontrib>IMPENS, I.</creatorcontrib><jtitle>Journal of experimental botany</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CEULEMANS, R.</au><au>KOCKELBERGH, F.</au><au>IMPENS, I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems</atitle><jtitle>Journal of experimental botany</jtitle><date>1986-08-01</date><risdate>1986</risdate><volume>37</volume><issue>181</issue><spage>1234</spage><epage>1244</epage><pages>1234-1244</pages><issn>0022-0957</issn><eissn>1460-2431</eissn><abstract>An improved and fast version of a closed loop system for measuring net CO2 exchange rates (NCER) in the field using a portable infrared gas analyser (IRGA) is described. An electronic timer—differentiator device measures and displays very accurately the time period necessary to bridge over a constant and preselected CO2 concentration difference. The time required for each measurement from start of the measurement to display of final results is c. 9 s for NCER of 24 μmol m—2 s—1. The measurement interval is sufficiently short that no environmental control in the perspex mini-cuvette is needed. Some satisfactory data of NCER measurements obtained under field and glasshouse conditions on poplar, sugar beet and winter wheat are presented.</abstract><pub>Clarendon Press</pub></addata></record>
fulltext fulltext
identifier ISSN: 0022-0957
ispartof Journal of experimental botany, 1986-08, Vol.37 (181), p.1234-1244
issn 0022-0957
1460-2431
language eng
recordid cdi_jstor_primary_23688618
source JSTOR Archival Journals and Primary Sources Collection; Oxford University Press Archive
subjects Carbon dioxide
Closed loop systems
Closed systems
Flux density
Photons
Photosynthesis
Plants
Pumps
Sugar beets
Timing devices
title A Fast, Low Cost and Low Power Requiring Device for Improving Closed Loop CO2Measuring Systems
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T19%3A00%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Fast,%20Low%20Cost%20and%20Low%20Power%20Requiring%20Device%20for%20Improving%20Closed%20Loop%20CO2Measuring%20Systems&rft.jtitle=Journal%20of%20experimental%20botany&rft.au=CEULEMANS,%20R.&rft.date=1986-08-01&rft.volume=37&rft.issue=181&rft.spage=1234&rft.epage=1244&rft.pages=1234-1244&rft.issn=0022-0957&rft.eissn=1460-2431&rft_id=info:doi/&rft_dat=%3Cjstor%3E23688618%3C/jstor%3E%3Cgrp_id%3Ecdi_FETCH-jstor_primary_236886183%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_jstor_id=23688618&rfr_iscdi=true