Loading…

Radiation Safety Issues in Y-90 Microsphere Selective Hepatic Radioembolization Therapy: Possible Radiation Exposure from the Patients

Purpose The purpose of this study was to estimate the possible external radiation dose to other individuals from patients treated with Y-90 resin microspheres for unresectable hepatocellular carcinoma. Methods We designed the study prospectively to estimate the possible radiation dose to other indiv...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear medicine and molecular imaging 2010, Vol.44 (4), p.252-260
Main Authors: Kim, Young-Chul, Kim, Yun-Hwan, Uhm, Soon-Ho, Seo, Yeon-Seok, Park, Eun-Kyung, Oh, Sun-Young, Jeong, Eu-Gene, Lee, Si-Nae, Choe, Jae-Gol
Format: Article
Language:Korean
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose The purpose of this study was to estimate the possible external radiation dose to other individuals from patients treated with Y-90 resin microspheres for unresectable hepatocellular carcinoma. Methods We designed the study prospectively to estimate the possible radiation dose to other individuals from patients who had been treated with Y-90 microspheres for unresectable hepatocellular carcinoma. We estimated the total effective dose equivalent (TEDE) using two methods: 'theoretical' TEDEs according to the administered activity and 'measured' TEDE based on the 'measured' ambient radiation exposure rate. We compared the results from each method to determine when we can release patients from confinement at the earliest time complying with the patient release criteria. Results A total of 20 administrations of Y-90 resin microspheres were done in 18 patients. The average administered activity was $1.2{\pm}0.77$ (0.28-2.97) GBq. The 'theoretical' TEDEs were in the range of $0.8-10\;{\mu}Sv$. The 'measured' TEDEs were in the range of $2.31-185\;{\mu}Sv$. The measured TEDEs tend to be higher than the theoretical TEDEs. The values of theoretical and measured TEDE were both far less than 1 mSv, the upper limit at which the licensee can release a patient without any written documents. Conclusion The effective dose equivalent caused by the Y-90 microsphere administered patient is very low. It is safe in terms of radiation safety to the other individuals when Y-90 microsphere radioembolization therapy is done with dose less than 3 GBq. Because the measured TEDE tends to be higher than the theoretical TEDE, it is recommended to use 'measured' TEDE for determining patient release.
ISSN:1869-3474
1869-3482