Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software
Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeter...
Saved in:
Published in: | Imaging science in dentistry 2018, Vol.48 (1), p.21-30 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | Korean |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 30 |
container_issue | 1 |
container_start_page | 21 |
container_title | Imaging science in dentistry |
container_volume | 48 |
creator | Kim, Eun-Kyung Han, Won-Jeong Choi, Jin-Woo Battulga, Bulgan |
description | Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs. |
format | article |
fullrecord | <record><control><sourceid>kisti</sourceid><recordid>TN_cdi_kisti_ndsl_JAKO201810648290849</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>JAKO201810648290849</sourcerecordid><originalsourceid>FETCH-kisti_ndsl_JAKO2018106482908493</originalsourceid><addsrcrecordid>eNqNjk1rAkEQRAdRUNT_0JccF2Zn_RiPQQwhIXjxLqPbo6O708t0myD--WwkeLYu9SjeoTpqYExRZHNb6O6DjemrMfNJt5kaO5_lA3VbsYTaSaAI5EGOCOg97iV8I5TE-LeWGMVVsKeI2Q5d3VLdXARLEKrpkFxzvMKFQzxAg4kp3uW7krKd41b8oigIS5cqAiYvPy7hSPW8qxjH_z1UL2-rzfI9O4f21DaWXG0_Xj_XRuc217OJNQttJ4viWe8Xfk9PnQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><source>PubMed Central(OpenAccess)</source><creator>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</creator><creatorcontrib>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</creatorcontrib><description>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</description><identifier>ISSN: 2233-7822</identifier><identifier>EISSN: 2233-7830</identifier><language>kor</language><ispartof>Imaging science in dentistry, 2018, Vol.48 (1), p.21-30</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,4009</link.rule.ids></links><search><creatorcontrib>Kim, Eun-Kyung</creatorcontrib><creatorcontrib>Han, Won-Jeong</creatorcontrib><creatorcontrib>Choi, Jin-Woo</creatorcontrib><creatorcontrib>Battulga, Bulgan</creatorcontrib><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><title>Imaging science in dentistry</title><addtitle>Imaging science in dentistry</addtitle><description>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</description><issn>2233-7822</issn><issn>2233-7830</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNjk1rAkEQRAdRUNT_0JccF2Zn_RiPQQwhIXjxLqPbo6O708t0myD--WwkeLYu9SjeoTpqYExRZHNb6O6DjemrMfNJt5kaO5_lA3VbsYTaSaAI5EGOCOg97iV8I5TE-LeWGMVVsKeI2Q5d3VLdXARLEKrpkFxzvMKFQzxAg4kp3uW7krKd41b8oigIS5cqAiYvPy7hSPW8qxjH_z1UL2-rzfI9O4f21DaWXG0_Xj_XRuc217OJNQttJ4viWe8Xfk9PnQ</recordid><startdate>2018</startdate><enddate>2018</enddate><creator>Kim, Eun-Kyung</creator><creator>Han, Won-Jeong</creator><creator>Choi, Jin-Woo</creator><creator>Battulga, Bulgan</creator><scope>JDI</scope></search><sort><creationdate>2018</creationdate><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><author>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kisti_ndsl_JAKO2018106482908493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2018</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Kim, Eun-Kyung</creatorcontrib><creatorcontrib>Han, Won-Jeong</creatorcontrib><creatorcontrib>Choi, Jin-Woo</creatorcontrib><creatorcontrib>Battulga, Bulgan</creatorcontrib><collection>KoreaScience</collection><jtitle>Imaging science in dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Eun-Kyung</au><au>Han, Won-Jeong</au><au>Choi, Jin-Woo</au><au>Battulga, Bulgan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</atitle><jtitle>Imaging science in dentistry</jtitle><addtitle>Imaging science in dentistry</addtitle><date>2018</date><risdate>2018</risdate><volume>48</volume><issue>1</issue><spage>21</spage><epage>30</epage><pages>21-30</pages><issn>2233-7822</issn><eissn>2233-7830</eissn><abstract>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</abstract><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2233-7822 |
ispartof | Imaging science in dentistry, 2018, Vol.48 (1), p.21-30 |
issn | 2233-7822 2233-7830 |
language | kor |
recordid | cdi_kisti_ndsl_JAKO201810648290849 |
source | PubMed Central(OpenAccess) |
title | Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T08%3A12%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kisti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimation%20of%20the%20effective%20dose%20of%20dental%20cone-beam%20computed%20tomography%20using%20personal%20computer-based%20Monte%20Carlo%20software&rft.jtitle=Imaging%20science%20in%20dentistry&rft.au=Kim,%20Eun-Kyung&rft.date=2018&rft.volume=48&rft.issue=1&rft.spage=21&rft.epage=30&rft.pages=21-30&rft.issn=2233-7822&rft.eissn=2233-7830&rft_id=info:doi/&rft_dat=%3Ckisti%3EJAKO201810648290849%3C/kisti%3E%3Cgrp_id%3Ecdi_FETCH-kisti_ndsl_JAKO2018106482908493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |