Loading…

Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software

Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeter...

Full description

Saved in:
Bibliographic Details
Published in:Imaging science in dentistry 2018, Vol.48 (1), p.21-30
Main Authors: Kim, Eun-Kyung, Han, Won-Jeong, Choi, Jin-Woo, Battulga, Bulgan
Format: Article
Language:Korean
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 30
container_issue 1
container_start_page 21
container_title Imaging science in dentistry
container_volume 48
creator Kim, Eun-Kyung
Han, Won-Jeong
Choi, Jin-Woo
Battulga, Bulgan
description Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.
format article
fullrecord <record><control><sourceid>kisti</sourceid><recordid>TN_cdi_kisti_ndsl_JAKO201810648290849</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>JAKO201810648290849</sourcerecordid><originalsourceid>FETCH-kisti_ndsl_JAKO2018106482908493</originalsourceid><addsrcrecordid>eNqNjk1rAkEQRAdRUNT_0JccF2Zn_RiPQQwhIXjxLqPbo6O708t0myD--WwkeLYu9SjeoTpqYExRZHNb6O6DjemrMfNJt5kaO5_lA3VbsYTaSaAI5EGOCOg97iV8I5TE-LeWGMVVsKeI2Q5d3VLdXARLEKrpkFxzvMKFQzxAg4kp3uW7krKd41b8oigIS5cqAiYvPy7hSPW8qxjH_z1UL2-rzfI9O4f21DaWXG0_Xj_XRuc217OJNQttJ4viWe8Xfk9PnQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><source>PubMed Central(OpenAccess)</source><creator>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</creator><creatorcontrib>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</creatorcontrib><description>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height &gt;10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</description><identifier>ISSN: 2233-7822</identifier><identifier>EISSN: 2233-7830</identifier><language>kor</language><ispartof>Imaging science in dentistry, 2018, Vol.48 (1), p.21-30</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,4009</link.rule.ids></links><search><creatorcontrib>Kim, Eun-Kyung</creatorcontrib><creatorcontrib>Han, Won-Jeong</creatorcontrib><creatorcontrib>Choi, Jin-Woo</creatorcontrib><creatorcontrib>Battulga, Bulgan</creatorcontrib><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><title>Imaging science in dentistry</title><addtitle>Imaging science in dentistry</addtitle><description>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height &gt;10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</description><issn>2233-7822</issn><issn>2233-7830</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNjk1rAkEQRAdRUNT_0JccF2Zn_RiPQQwhIXjxLqPbo6O708t0myD--WwkeLYu9SjeoTpqYExRZHNb6O6DjemrMfNJt5kaO5_lA3VbsYTaSaAI5EGOCOg97iV8I5TE-LeWGMVVsKeI2Q5d3VLdXARLEKrpkFxzvMKFQzxAg4kp3uW7krKd41b8oigIS5cqAiYvPy7hSPW8qxjH_z1UL2-rzfI9O4f21DaWXG0_Xj_XRuc217OJNQttJ4viWe8Xfk9PnQ</recordid><startdate>2018</startdate><enddate>2018</enddate><creator>Kim, Eun-Kyung</creator><creator>Han, Won-Jeong</creator><creator>Choi, Jin-Woo</creator><creator>Battulga, Bulgan</creator><scope>JDI</scope></search><sort><creationdate>2018</creationdate><title>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</title><author>Kim, Eun-Kyung ; Han, Won-Jeong ; Choi, Jin-Woo ; Battulga, Bulgan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-kisti_ndsl_JAKO2018106482908493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>kor</language><creationdate>2018</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Kim, Eun-Kyung</creatorcontrib><creatorcontrib>Han, Won-Jeong</creatorcontrib><creatorcontrib>Choi, Jin-Woo</creatorcontrib><creatorcontrib>Battulga, Bulgan</creatorcontrib><collection>KoreaScience</collection><jtitle>Imaging science in dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Eun-Kyung</au><au>Han, Won-Jeong</au><au>Choi, Jin-Woo</au><au>Battulga, Bulgan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software</atitle><jtitle>Imaging science in dentistry</jtitle><addtitle>Imaging science in dentistry</addtitle><date>2018</date><risdate>2018</risdate><volume>48</volume><issue>1</issue><spage>21</spage><epage>30</epage><pages>21-30</pages><issn>2233-7822</issn><eissn>2233-7830</eissn><abstract>Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height &gt;10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2233-7822
ispartof Imaging science in dentistry, 2018, Vol.48 (1), p.21-30
issn 2233-7822
2233-7830
language kor
recordid cdi_kisti_ndsl_JAKO201810648290849
source PubMed Central(OpenAccess)
title Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T08%3A12%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-kisti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Estimation%20of%20the%20effective%20dose%20of%20dental%20cone-beam%20computed%20tomography%20using%20personal%20computer-based%20Monte%20Carlo%20software&rft.jtitle=Imaging%20science%20in%20dentistry&rft.au=Kim,%20Eun-Kyung&rft.date=2018&rft.volume=48&rft.issue=1&rft.spage=21&rft.epage=30&rft.pages=21-30&rft.issn=2233-7822&rft.eissn=2233-7830&rft_id=info:doi/&rft_dat=%3Ckisti%3EJAKO201810648290849%3C/kisti%3E%3Cgrp_id%3Ecdi_FETCH-kisti_ndsl_JAKO2018106482908493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true