Loading…

Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study

To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS. An F...

Full description

Saved in:
Bibliographic Details
Published in:Clinical endoscopy 2014, 47(1), , pp.84-93
Main Authors: Lee, Sang Soo, Song, Tae Jun, Joo, Mee, Park, Do Hyun, Seo, Dong Wan, Lee, Sung Koo, Kim, Myung-Hwan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3
cites cdi_FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3
container_end_page 93
container_issue 1
container_start_page 84
container_title Clinical endoscopy
container_volume 47
creator Lee, Sang Soo
Song, Tae Jun
Joo, Mee
Park, Do Hyun
Seo, Dong Wan
Lee, Sung Koo
Kim, Myung-Hwan
description To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS. An FCSEMS was inserted into the common bile duct of 12 canines, and the animals were divided into four groups. Posteuthanasia, necropsy was performed to examine the histopathological changes in the bile ducts after 1, 3, 6, and 9 months. The results of necropsy showed that the covered membranes of the FCSEMSs were intact and easily removed from the bile ducts in 11 of the canines. Severe epithelial hyperplasia of the stented bile duct and epithelial ingrowth into the stent occurred in one animal (from the 3-month group). On histopathological examination, mild inflammatory changes were observed in the stented bile ducts, and there was no significant difference between the four groups. Among the 12 animals, five had de novo stricture. An FCSEMS can be inserted into the bile duct without severe histopathological changes up until 9 months. However, a de novo stricture and severe epithelial hyperplasia relating to the stent insertion might occur.
doi_str_mv 10.5946/ce.2014.47.1.84
format article
fullrecord <record><control><sourceid>proquest_nrf_k</sourceid><recordid>TN_cdi_nrf_kci_oai_kci_go_kr_ARTI_1129186</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1502996782</sourcerecordid><originalsourceid>FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3</originalsourceid><addsrcrecordid>eNpVkcFu1DAQQCMEolXpmRvyEQ5Jbccb2xyQltDSSotAdDlbjjPZNXXsrZMU9k_6ufV2ywI-eCzNmzceTZa9JriYSVadGSgoJqxgvCCFYM-yY0pLllPGyueHN8ZH2ekw_MTpVJgSOXuZHVE241gIcZzdX9phDC6srNEO1WvtVzAg69G4BvTROkCfJjMi3Y0Q0SL4Vb6E2KNvThvowY8odEiji8m5LarDHURo0TW4Lj__vdG-1U0yfIExua_HHf7Ljutk1wnu--D_tniP5qjW3npI5NRuX2UvOu0GOH2KJ9mPi_NlfZkvvn6-queL3DDKx90tOiZISWXHcJdmbihUtDKkLXUrRYMrVrUV57phknGMG65pShLaCmg4lCfZu73Xx07dGKuCto9xFdRNVPPvyytFCJVEVIn9sGc3U9NDa9JAUTu1ibbXcftY-X_G23Xy3KlSUsGkSIK3T4IYbicYRtXbwYBz2kOYBkVmmEpZcUETerZHTQzDEKE7tCFY7davDKjd-hXjiijBUsWbf3934P8su3wAOzirPQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1502996782</pqid></control><display><type>article</type><title>Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study</title><source>PubMed Central</source><creator>Lee, Sang Soo ; Song, Tae Jun ; Joo, Mee ; Park, Do Hyun ; Seo, Dong Wan ; Lee, Sung Koo ; Kim, Myung-Hwan</creator><creatorcontrib>Lee, Sang Soo ; Song, Tae Jun ; Joo, Mee ; Park, Do Hyun ; Seo, Dong Wan ; Lee, Sung Koo ; Kim, Myung-Hwan</creatorcontrib><description>To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS. An FCSEMS was inserted into the common bile duct of 12 canines, and the animals were divided into four groups. Posteuthanasia, necropsy was performed to examine the histopathological changes in the bile ducts after 1, 3, 6, and 9 months. The results of necropsy showed that the covered membranes of the FCSEMSs were intact and easily removed from the bile ducts in 11 of the canines. Severe epithelial hyperplasia of the stented bile duct and epithelial ingrowth into the stent occurred in one animal (from the 3-month group). On histopathological examination, mild inflammatory changes were observed in the stented bile ducts, and there was no significant difference between the four groups. Among the 12 animals, five had de novo stricture. An FCSEMS can be inserted into the bile duct without severe histopathological changes up until 9 months. However, a de novo stricture and severe epithelial hyperplasia relating to the stent insertion might occur.</description><identifier>ISSN: 2234-2400</identifier><identifier>EISSN: 2234-2443</identifier><identifier>DOI: 10.5946/ce.2014.47.1.84</identifier><identifier>PMID: 24570888</identifier><language>eng</language><publisher>Korea (South): The Korean Society of Gastrointestinal Endoscopy</publisher><subject>Original ; 내과학</subject><ispartof>Clinical Endoscopy, 2014, 47(1), , pp.84-93</ispartof><rights>Copyright © 2014 Korean Society of Gastrointestinal Endoscopy 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3</citedby><cites>FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3928498/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3928498/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,4010,27900,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24570888$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001846311$$DAccess content in National Research Foundation of Korea (NRF)$$Hfree_for_read</backlink></links><search><creatorcontrib>Lee, Sang Soo</creatorcontrib><creatorcontrib>Song, Tae Jun</creatorcontrib><creatorcontrib>Joo, Mee</creatorcontrib><creatorcontrib>Park, Do Hyun</creatorcontrib><creatorcontrib>Seo, Dong Wan</creatorcontrib><creatorcontrib>Lee, Sung Koo</creatorcontrib><creatorcontrib>Kim, Myung-Hwan</creatorcontrib><title>Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study</title><title>Clinical endoscopy</title><addtitle>Clin Endosc</addtitle><description>To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS. An FCSEMS was inserted into the common bile duct of 12 canines, and the animals were divided into four groups. Posteuthanasia, necropsy was performed to examine the histopathological changes in the bile ducts after 1, 3, 6, and 9 months. The results of necropsy showed that the covered membranes of the FCSEMSs were intact and easily removed from the bile ducts in 11 of the canines. Severe epithelial hyperplasia of the stented bile duct and epithelial ingrowth into the stent occurred in one animal (from the 3-month group). On histopathological examination, mild inflammatory changes were observed in the stented bile ducts, and there was no significant difference between the four groups. Among the 12 animals, five had de novo stricture. An FCSEMS can be inserted into the bile duct without severe histopathological changes up until 9 months. However, a de novo stricture and severe epithelial hyperplasia relating to the stent insertion might occur.</description><subject>Original</subject><subject>내과학</subject><issn>2234-2400</issn><issn>2234-2443</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpVkcFu1DAQQCMEolXpmRvyEQ5Jbccb2xyQltDSSotAdDlbjjPZNXXsrZMU9k_6ufV2ywI-eCzNmzceTZa9JriYSVadGSgoJqxgvCCFYM-yY0pLllPGyueHN8ZH2ekw_MTpVJgSOXuZHVE241gIcZzdX9phDC6srNEO1WvtVzAg69G4BvTROkCfJjMi3Y0Q0SL4Vb6E2KNvThvowY8odEiji8m5LarDHURo0TW4Lj__vdG-1U0yfIExua_HHf7Ljutk1wnu--D_tniP5qjW3npI5NRuX2UvOu0GOH2KJ9mPi_NlfZkvvn6-queL3DDKx90tOiZISWXHcJdmbihUtDKkLXUrRYMrVrUV57phknGMG65pShLaCmg4lCfZu73Xx07dGKuCto9xFdRNVPPvyytFCJVEVIn9sGc3U9NDa9JAUTu1ibbXcftY-X_G23Xy3KlSUsGkSIK3T4IYbicYRtXbwYBz2kOYBkVmmEpZcUETerZHTQzDEKE7tCFY7davDKjd-hXjiijBUsWbf3934P8su3wAOzirPQ</recordid><startdate>201401</startdate><enddate>201401</enddate><creator>Lee, Sang Soo</creator><creator>Song, Tae Jun</creator><creator>Joo, Mee</creator><creator>Park, Do Hyun</creator><creator>Seo, Dong Wan</creator><creator>Lee, Sung Koo</creator><creator>Kim, Myung-Hwan</creator><general>The Korean Society of Gastrointestinal Endoscopy</general><general>대한소화기내시경학회</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>ACYCR</scope></search><sort><creationdate>201401</creationdate><title>Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study</title><author>Lee, Sang Soo ; Song, Tae Jun ; Joo, Mee ; Park, Do Hyun ; Seo, Dong Wan ; Lee, Sung Koo ; Kim, Myung-Hwan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Original</topic><topic>내과학</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lee, Sang Soo</creatorcontrib><creatorcontrib>Song, Tae Jun</creatorcontrib><creatorcontrib>Joo, Mee</creatorcontrib><creatorcontrib>Park, Do Hyun</creatorcontrib><creatorcontrib>Seo, Dong Wan</creatorcontrib><creatorcontrib>Lee, Sung Koo</creatorcontrib><creatorcontrib>Kim, Myung-Hwan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Korean Citation Index</collection><jtitle>Clinical endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lee, Sang Soo</au><au>Song, Tae Jun</au><au>Joo, Mee</au><au>Park, Do Hyun</au><au>Seo, Dong Wan</au><au>Lee, Sung Koo</au><au>Kim, Myung-Hwan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study</atitle><jtitle>Clinical endoscopy</jtitle><addtitle>Clin Endosc</addtitle><date>2014-01</date><risdate>2014</risdate><volume>47</volume><issue>1</issue><spage>84</spage><epage>93</epage><pages>84-93</pages><issn>2234-2400</issn><eissn>2234-2443</eissn><abstract>To date, it has been difficult to determine the optimal stenting duration of a fully covered self-expandable metal stent (FCSEMS) in a benign biliary stricture. The purpose of this study was to identify the histopathological changes in a bile duct resulting from long-term placement of a FCSEMS. An FCSEMS was inserted into the common bile duct of 12 canines, and the animals were divided into four groups. Posteuthanasia, necropsy was performed to examine the histopathological changes in the bile ducts after 1, 3, 6, and 9 months. The results of necropsy showed that the covered membranes of the FCSEMSs were intact and easily removed from the bile ducts in 11 of the canines. Severe epithelial hyperplasia of the stented bile duct and epithelial ingrowth into the stent occurred in one animal (from the 3-month group). On histopathological examination, mild inflammatory changes were observed in the stented bile ducts, and there was no significant difference between the four groups. Among the 12 animals, five had de novo stricture. An FCSEMS can be inserted into the bile duct without severe histopathological changes up until 9 months. However, a de novo stricture and severe epithelial hyperplasia relating to the stent insertion might occur.</abstract><cop>Korea (South)</cop><pub>The Korean Society of Gastrointestinal Endoscopy</pub><pmid>24570888</pmid><doi>10.5946/ce.2014.47.1.84</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2234-2400
ispartof Clinical Endoscopy, 2014, 47(1), , pp.84-93
issn 2234-2400
2234-2443
language eng
recordid cdi_nrf_kci_oai_kci_go_kr_ARTI_1129186
source PubMed Central
subjects Original
내과학
title Histological Changes in the Bile Duct after Long-Term Placement of a Fully Covered Self-Expandable Metal Stent within a Common Bile Duct: A Canine Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T08%3A35%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_nrf_k&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Histological%20Changes%20in%20the%20Bile%20Duct%20after%20Long-Term%20Placement%20of%20a%20Fully%20Covered%20Self-Expandable%20Metal%20Stent%20within%20a%20Common%20Bile%20Duct:%20A%20Canine%20Study&rft.jtitle=Clinical%20endoscopy&rft.au=Lee,%20Sang%20Soo&rft.date=2014-01&rft.volume=47&rft.issue=1&rft.spage=84&rft.epage=93&rft.pages=84-93&rft.issn=2234-2400&rft.eissn=2234-2443&rft_id=info:doi/10.5946/ce.2014.47.1.84&rft_dat=%3Cproquest_nrf_k%3E1502996782%3C/proquest_nrf_k%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c427t-c428f481329f40f234b2e626c1d3ad98b0646d677ab494700b7a2c1d12d8eb7e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1502996782&rft_id=info:pmid/24570888&rfr_iscdi=true