Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery
During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis...
Saved in:
Published in: | Korean circulation journal 2013, 43(11), , pp.761-765 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3 |
---|---|
cites | cdi_FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3 |
container_end_page | 765 |
container_issue | 11 |
container_start_page | 761 |
container_title | Korean circulation journal |
container_volume | 43 |
creator | Kim, Tae-Jin Kim, Jae-Kyun Park, Bo-Min Song, Pil-Sang Kim, Dong-Kie Kim, Ki-Hun Seol, Sang-Hoon Kim, Doo-Il |
description | During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis. There are several methods being recommended for the treatment of fractured guidewire remnants. However, the best treatment of remnant guidewire filament is still unclear. Herein, we present a case where we did not completely remove remnant guidewire filaments that caused fatal coronary thrombosis. |
doi_str_mv | 10.4070/kcj.2013.43.11.761 |
format | article |
fullrecord | <record><control><sourceid>proquest_nrf_k</sourceid><recordid>TN_cdi_nrf_kci_oai_kci_go_kr_ARTI_1178686</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1490742487</sourcerecordid><originalsourceid>FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3</originalsourceid><addsrcrecordid>eNpVkV9rFDEUxYMotla_gA-SR33YMf8mybwIpdhaKAhSn0PmTtLN7sykJpmW_fbNduuiebkXcs65PzgIfaSkEUSRr1vYNIxQ3gjeUNooSV-hU6q4XrX1vT7ujJygdzlvCJFCsO4tOmGCS65adorGS1vsiPPSW1iKw7m4ueCyTnHqYw4Zh3lYwA243-G7JQzuMSSHfbJQlro8hrLGyRUb5qrxYbRT9e9dNcNhiCnONu2wTcWl3Xv0xtsxuw8v8wz9vvx-e_FjdfPz6vri_GYFlausvGaDs9AxCa4dFOGEMc081RqU7EhPWgu8E95aUFRTz_sBRK-gJQ6oHCw_Q18OuXPyZgvBRBue510022TOf91eG0qVllpW7beD9n7pJzdAxU92NPcpTBX82fn_zxzWNefBcC0lp_uAzy8BKf5ZXC5mChncONrZxSUbKjqiBBNaVSk7SCHFnJPzxzOUmH2lFXJj9pUawSuhqZVW06d_AY-Wvx3yJwuPoJM</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1490742487</pqid></control><display><type>article</type><title>Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery</title><source>PubMed Central(OpenAccess)</source><creator>Kim, Tae-Jin ; Kim, Jae-Kyun ; Park, Bo-Min ; Song, Pil-Sang ; Kim, Dong-Kie ; Kim, Ki-Hun ; Seol, Sang-Hoon ; Kim, Doo-Il</creator><creatorcontrib>Kim, Tae-Jin ; Kim, Jae-Kyun ; Park, Bo-Min ; Song, Pil-Sang ; Kim, Dong-Kie ; Kim, Ki-Hun ; Seol, Sang-Hoon ; Kim, Doo-Il</creatorcontrib><description>During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis. There are several methods being recommended for the treatment of fractured guidewire remnants. However, the best treatment of remnant guidewire filament is still unclear. Herein, we present a case where we did not completely remove remnant guidewire filaments that caused fatal coronary thrombosis.</description><identifier>ISSN: 1738-5520</identifier><identifier>EISSN: 1738-5555</identifier><identifier>DOI: 10.4070/kcj.2013.43.11.761</identifier><identifier>PMID: 24363752</identifier><language>eng</language><publisher>Korea (South): The Korean Society of Cardiology</publisher><subject>Case Report ; 내과학</subject><ispartof>Korean Circulation Journal, 2013, 43(11), , pp.761-765</ispartof><rights>Copyright © 2013 The Korean Society of Cardiology 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3</citedby><cites>FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866316/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866316/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24363752$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001824353$$DAccess content in National Research Foundation of Korea (NRF)$$Hfree_for_read</backlink></links><search><creatorcontrib>Kim, Tae-Jin</creatorcontrib><creatorcontrib>Kim, Jae-Kyun</creatorcontrib><creatorcontrib>Park, Bo-Min</creatorcontrib><creatorcontrib>Song, Pil-Sang</creatorcontrib><creatorcontrib>Kim, Dong-Kie</creatorcontrib><creatorcontrib>Kim, Ki-Hun</creatorcontrib><creatorcontrib>Seol, Sang-Hoon</creatorcontrib><creatorcontrib>Kim, Doo-Il</creatorcontrib><title>Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery</title><title>Korean circulation journal</title><addtitle>Korean Circ J</addtitle><description>During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis. There are several methods being recommended for the treatment of fractured guidewire remnants. However, the best treatment of remnant guidewire filament is still unclear. Herein, we present a case where we did not completely remove remnant guidewire filaments that caused fatal coronary thrombosis.</description><subject>Case Report</subject><subject>내과학</subject><issn>1738-5520</issn><issn>1738-5555</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpVkV9rFDEUxYMotla_gA-SR33YMf8mybwIpdhaKAhSn0PmTtLN7sykJpmW_fbNduuiebkXcs65PzgIfaSkEUSRr1vYNIxQ3gjeUNooSV-hU6q4XrX1vT7ujJygdzlvCJFCsO4tOmGCS65adorGS1vsiPPSW1iKw7m4ueCyTnHqYw4Zh3lYwA243-G7JQzuMSSHfbJQlro8hrLGyRUb5qrxYbRT9e9dNcNhiCnONu2wTcWl3Xv0xtsxuw8v8wz9vvx-e_FjdfPz6vri_GYFlausvGaDs9AxCa4dFOGEMc081RqU7EhPWgu8E95aUFRTz_sBRK-gJQ6oHCw_Q18OuXPyZgvBRBue510022TOf91eG0qVllpW7beD9n7pJzdAxU92NPcpTBX82fn_zxzWNefBcC0lp_uAzy8BKf5ZXC5mChncONrZxSUbKjqiBBNaVSk7SCHFnJPzxzOUmH2lFXJj9pUawSuhqZVW06d_AY-Wvx3yJwuPoJM</recordid><startdate>20131101</startdate><enddate>20131101</enddate><creator>Kim, Tae-Jin</creator><creator>Kim, Jae-Kyun</creator><creator>Park, Bo-Min</creator><creator>Song, Pil-Sang</creator><creator>Kim, Dong-Kie</creator><creator>Kim, Ki-Hun</creator><creator>Seol, Sang-Hoon</creator><creator>Kim, Doo-Il</creator><general>The Korean Society of Cardiology</general><general>대한심장학회</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>ACYCR</scope></search><sort><creationdate>20131101</creationdate><title>Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery</title><author>Kim, Tae-Jin ; Kim, Jae-Kyun ; Park, Bo-Min ; Song, Pil-Sang ; Kim, Dong-Kie ; Kim, Ki-Hun ; Seol, Sang-Hoon ; Kim, Doo-Il</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Case Report</topic><topic>내과학</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Tae-Jin</creatorcontrib><creatorcontrib>Kim, Jae-Kyun</creatorcontrib><creatorcontrib>Park, Bo-Min</creatorcontrib><creatorcontrib>Song, Pil-Sang</creatorcontrib><creatorcontrib>Kim, Dong-Kie</creatorcontrib><creatorcontrib>Kim, Ki-Hun</creatorcontrib><creatorcontrib>Seol, Sang-Hoon</creatorcontrib><creatorcontrib>Kim, Doo-Il</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Korean Citation Index</collection><jtitle>Korean circulation journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Tae-Jin</au><au>Kim, Jae-Kyun</au><au>Park, Bo-Min</au><au>Song, Pil-Sang</au><au>Kim, Dong-Kie</au><au>Kim, Ki-Hun</au><au>Seol, Sang-Hoon</au><au>Kim, Doo-Il</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery</atitle><jtitle>Korean circulation journal</jtitle><addtitle>Korean Circ J</addtitle><date>2013-11-01</date><risdate>2013</risdate><volume>43</volume><issue>11</issue><spage>761</spage><epage>765</epage><pages>761-765</pages><issn>1738-5520</issn><eissn>1738-5555</eissn><abstract>During percutaneous coronary intervention, guidewire fractures are very exceptionally encountered in medical practice, but can cause fatal complications such as intracoronary thrombus formation, embolization and perforation. Removal of the remnant segments of guidewire is important for the prognosis. There are several methods being recommended for the treatment of fractured guidewire remnants. However, the best treatment of remnant guidewire filament is still unclear. Herein, we present a case where we did not completely remove remnant guidewire filaments that caused fatal coronary thrombosis.</abstract><cop>Korea (South)</cop><pub>The Korean Society of Cardiology</pub><pmid>24363752</pmid><doi>10.4070/kcj.2013.43.11.761</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1738-5520 |
ispartof | Korean Circulation Journal, 2013, 43(11), , pp.761-765 |
issn | 1738-5520 1738-5555 |
language | eng |
recordid | cdi_nrf_kci_oai_kci_go_kr_ARTI_1178686 |
source | PubMed Central(OpenAccess) |
subjects | Case Report 내과학 |
title | Fatal subacute stent thrombosis induced by guidewire fracture with retained filaments in the coronary artery |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T23%3A43%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_nrf_k&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fatal%20subacute%20stent%20thrombosis%20induced%20by%20guidewire%20fracture%20with%20retained%20filaments%20in%20the%20coronary%20artery&rft.jtitle=Korean%20circulation%20journal&rft.au=Kim,%20Tae-Jin&rft.date=2013-11-01&rft.volume=43&rft.issue=11&rft.spage=761&rft.epage=765&rft.pages=761-765&rft.issn=1738-5520&rft.eissn=1738-5555&rft_id=info:doi/10.4070/kcj.2013.43.11.761&rft_dat=%3Cproquest_nrf_k%3E1490742487%3C/proquest_nrf_k%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c436t-f82deac926ce5d70302282f188c7690b05ac394faac7181f3bdc4b7c50ec16da3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1490742487&rft_id=info:pmid/24363752&rfr_iscdi=true |