Loading…

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

The aim of this study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Thirty-two premolars with single canals that required extraction were inc...

Full description

Saved in:
Bibliographic Details
Published in:Restorative dentistry & endodontics 2017, 42(3), , pp.200-205
Main Authors: Tampelini, Fernanda Garcia, Coelho, Marcelo Santos, Rios, Marcos de Azevêdo, Fontana, Carlos Eduardo, Rocha, Daniel Guimarães Pedro, Pinheiro, Sergio Luiz, Bueno, Carlos Eduardo da Silveira
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of this study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a × 25 magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II ( = 0.94), followed by Propex II ( = 0.90) and Ingle's technique ( = 0.81; < 0.001). Descriptive statistics using ANOVA (Tukey's test) revealed significant differences between the radiographic measurements and both EALs measurements ( < 0.05). Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.
ISSN:2234-7658
2234-7666
DOI:10.5395/rde.2017.42.3.200