Loading…
Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract
Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When dete...
Saved in:
Published in: | Pediatric gastroenterology, hepatology & nutrition 2019, Hepatology & Nutrition, 22(2), , pp.132-141 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853 |
---|---|
cites | cdi_FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853 |
container_end_page | 141 |
container_issue | 2 |
container_start_page | 132 |
container_title | Pediatric gastroenterology, hepatology & nutrition |
container_volume | 22 |
creator | Choe, Jae Young Choe, Byung-Ho |
description | Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnet-attached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object). |
doi_str_mv | 10.5223/pghn.2019.22.2.132 |
format | article |
fullrecord | <record><control><sourceid>proquest_nrf_k</sourceid><recordid>TN_cdi_nrf_kci_oai_kci_go_kr_ARTI_4506886</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2196512245</sourcerecordid><originalsourceid>FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853</originalsourceid><addsrcrecordid>eNpVkU9PGzEQxa2qqCDKF-BQ-dgesvW_9dqXSjRqKBIVEgpn49jejcuundoOUr59HQIIfBlL895vZvQAOMeoaQmh3zfDOjQEYdkQ0pAGU_IBnNQGmwnB0MeXP2f8GJzl_BfV12FKMf4EjikSUnIhT8D9IibnhwB_RruDt26Kj3qEPsD52o82uQDvsg8DXMTR7eBcl7UrLsGY4B89BFfgcrtysE9xgpc6lxR9KC4XHyplmbQpn8FRr8fszp7rKbhb_FrOf8-uby6v5hfXM8MoLzODJdfSip5bZozrOBOitbJlkmrBiUVEYqktIbrrutZhizrJTIcM0ytqREtPwbcDN6RePRivovZPdYjqIamL2-WVYi3iQvCq_XHQbraryVnjQkl6VJvkJ512T873neDXlfOoOMOcClwBX58BKf7b1nvV5LNx46iDi9usSL2mxYSw_V7kIDUp5pxc_zoGI7VPUu2TVPskFSGKqJpkNX15u-Cr5SU3-h_IB5qm</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2196512245</pqid></control><display><type>article</type><title>Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract</title><source>Open Access: PubMed Central</source><creator>Choe, Jae Young ; Choe, Byung-Ho</creator><creatorcontrib>Choe, Jae Young ; Choe, Byung-Ho</creatorcontrib><description>Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnet-attached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).</description><identifier>ISSN: 2234-8646</identifier><identifier>EISSN: 2234-8840</identifier><identifier>DOI: 10.5223/pghn.2019.22.2.132</identifier><identifier>PMID: 30899689</identifier><language>eng</language><publisher>Korea (South): The Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition</publisher><subject>Review ; 소아과학</subject><ispartof>Pediatric Gastroenterology, 2019, Hepatology & Nutrition, 22(2), , pp.132-141</ispartof><rights>Copyright © 2019 by The Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition 2019 The Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853</citedby><cites>FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416381/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416381/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30899689$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002446918$$DAccess content in National Research Foundation of Korea (NRF)$$Hfree_for_read</backlink></links><search><creatorcontrib>Choe, Jae Young</creatorcontrib><creatorcontrib>Choe, Byung-Ho</creatorcontrib><title>Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract</title><title>Pediatric gastroenterology, hepatology & nutrition</title><addtitle>Pediatr Gastroenterol Hepatol Nutr</addtitle><description>Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnet-attached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).</description><subject>Review</subject><subject>소아과학</subject><issn>2234-8646</issn><issn>2234-8840</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpVkU9PGzEQxa2qqCDKF-BQ-dgesvW_9dqXSjRqKBIVEgpn49jejcuundoOUr59HQIIfBlL895vZvQAOMeoaQmh3zfDOjQEYdkQ0pAGU_IBnNQGmwnB0MeXP2f8GJzl_BfV12FKMf4EjikSUnIhT8D9IibnhwB_RruDt26Kj3qEPsD52o82uQDvsg8DXMTR7eBcl7UrLsGY4B89BFfgcrtysE9xgpc6lxR9KC4XHyplmbQpn8FRr8fszp7rKbhb_FrOf8-uby6v5hfXM8MoLzODJdfSip5bZozrOBOitbJlkmrBiUVEYqktIbrrutZhizrJTIcM0ytqREtPwbcDN6RePRivovZPdYjqIamL2-WVYi3iQvCq_XHQbraryVnjQkl6VJvkJ512T873neDXlfOoOMOcClwBX58BKf7b1nvV5LNx46iDi9usSL2mxYSw_V7kIDUp5pxc_zoGI7VPUu2TVPskFSGKqJpkNX15u-Cr5SU3-h_IB5qm</recordid><startdate>20190301</startdate><enddate>20190301</enddate><creator>Choe, Jae Young</creator><creator>Choe, Byung-Ho</creator><general>The Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition</general><general>대한소아소화기영양학회</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>ACYCR</scope></search><sort><creationdate>20190301</creationdate><title>Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract</title><author>Choe, Jae Young ; Choe, Byung-Ho</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Review</topic><topic>소아과학</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choe, Jae Young</creatorcontrib><creatorcontrib>Choe, Byung-Ho</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Korean Citation Index</collection><jtitle>Pediatric gastroenterology, hepatology & nutrition</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choe, Jae Young</au><au>Choe, Byung-Ho</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract</atitle><jtitle>Pediatric gastroenterology, hepatology & nutrition</jtitle><addtitle>Pediatr Gastroenterol Hepatol Nutr</addtitle><date>2019-03-01</date><risdate>2019</risdate><volume>22</volume><issue>2</issue><spage>132</spage><epage>141</epage><pages>132-141</pages><issn>2234-8646</issn><eissn>2234-8840</eissn><abstract>Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnet-attached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).</abstract><cop>Korea (South)</cop><pub>The Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition</pub><pmid>30899689</pmid><doi>10.5223/pghn.2019.22.2.132</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2234-8646 |
ispartof | Pediatric Gastroenterology, 2019, Hepatology & Nutrition, 22(2), , pp.132-141 |
issn | 2234-8646 2234-8840 |
language | eng |
recordid | cdi_nrf_kci_oai_kci_go_kr_ARTI_4506886 |
source | Open Access: PubMed Central |
subjects | Review 소아과학 |
title | Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T15%3A12%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_nrf_k&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Foreign%20Body%20Removal%20in%20Children%20Using%20Foley%20Catheter%20or%20Magnet%20Tube%20from%20Gastrointestinal%20Tract&rft.jtitle=Pediatric%20gastroenterology,%20hepatology%20&%20nutrition&rft.au=Choe,%20Jae%20Young&rft.date=2019-03-01&rft.volume=22&rft.issue=2&rft.spage=132&rft.epage=141&rft.pages=132-141&rft.issn=2234-8646&rft.eissn=2234-8840&rft_id=info:doi/10.5223/pghn.2019.22.2.132&rft_dat=%3Cproquest_nrf_k%3E2196512245%3C/proquest_nrf_k%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c436t-c196a9d8f6d4cce764885d95493a862d02919ad22a7775e1d0794c70c4ab3c853%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2196512245&rft_id=info:pmid/30899689&rfr_iscdi=true |