Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair
A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This sh...
Saved in:
Published in: | Journal of chest surgery 2019, 52(4), , pp.232-235 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output. |
---|---|