Loading…
Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair
A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This sh...
Saved in:
Published in: | Journal of chest surgery 2019, 52(4), , pp.232-235 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c3372-476f568aa944926cd9b30d536195cf969595bdfa5ca37b6b635a93cf516180613 |
container_end_page | 235 |
container_issue | 4 |
container_start_page | 232 |
container_title | Journal of chest surgery |
container_volume | 52 |
creator | Shin, Yu Rim Yang, Young Ho Park, Young-Hwan Park, Han Ki |
description | A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output. |
doi_str_mv | 10.5090/kjtcs.2019.52.4.232 |
format | article |
fullrecord | <record><control><sourceid>pubmed_nrf_k</sourceid><recordid>TN_cdi_nrf_kci_oai_kci_go_kr_ARTI_5938311</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_0a74df98f74d4714886181f6ecadfd52</doaj_id><sourcerecordid>31403029</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3372-476f568aa944926cd9b30d536195cf969595bdfa5ca37b6b635a93cf516180613</originalsourceid><addsrcrecordid>eNpVks1qGzEUhYfS0oQ0T1Ao2nYxU_2MNKNNwTVJYzBtSFLoTtzRSLY89shIcsDvkoetbKch0eaKq3O-K4lTFJ8JrjiW-NuwSjpWFBNZcVrVFWX0XXFOsWSl4ES8z3vK8h6Tv2fFZYwrnJfAlDfNx-KMkRozTOV58XS1MWFhRr1Ht7v1xo8Q9mgSkgn7Mvnyfh-T2Tj93EL3y92YUPLoRzAwoLQ06NZHl9yjQdfG9B3oAc293yJvEbxC3uy3JiPGeFBOg4suIrCZiX6ZrEiwRlMPQSdIzo_ozmzBhU_FBwvraC6f60Xx5_rqYXpTzn__nE0n81Iz1tCyboTlogWQdS2p0L3sGO45E0RybaWQXPKut8A1sKYTnWAcJNM2_xNpsSDsovh64o7BqkE75cEd68KrIajJ3cNMcclaRg7a2Unbe1ipbXCb_Lyj4djwYaEgJKfXRmFo6t7K1uZSN6Ru2zyPWGE09LbnNLO-n1jbXbcxvTZjCrB-A317MrplvtOjEqJtcC0ygJ0AOvgYg7EvXoLVISfqmBN1yIniVNUq5yS7vrwe--L5nwr2DzIYvRg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair</title><source>PubMed Central</source><source>Directory of Open Access Journals</source><creator>Shin, Yu Rim ; Yang, Young Ho ; Park, Young-Hwan ; Park, Han Ki</creator><creatorcontrib>Shin, Yu Rim ; Yang, Young Ho ; Park, Young-Hwan ; Park, Han Ki</creatorcontrib><description>A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output.</description><identifier>ISSN: 2233-601X</identifier><identifier>ISSN: 2765-1606</identifier><identifier>EISSN: 2093-6516</identifier><identifier>EISSN: 2765-1614</identifier><identifier>DOI: 10.5090/kjtcs.2019.52.4.232</identifier><identifier>PMID: 31403029</identifier><language>eng</language><publisher>Korea (South): The Korean Society for Thoracic and Cardiovascular Surgery</publisher><subject>Aortic coarctation ; Case Report ; Hypoplastic left heart syndrome ; Pulmonary hypertension ; Shunts ; 흉부외과학</subject><ispartof>Journal of Chest Surgery, 2019, 52(4), , pp.232-235</ispartof><rights>Copyright © 2019 by The Korean Society for Thoracic and Cardiovascular Surgery. All rights Reserved. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3372-476f568aa944926cd9b30d536195cf969595bdfa5ca37b6b635a93cf516180613</cites><orcidid>0000-0002-0977-0525 ; 0000-0002-7472-7822 ; 0000-0001-7685-0018 ; 0000-0001-9802-8017</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687046/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687046/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31403029$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002491518$$DAccess content in National Research Foundation of Korea (NRF)$$Hfree_for_read</backlink></links><search><creatorcontrib>Shin, Yu Rim</creatorcontrib><creatorcontrib>Yang, Young Ho</creatorcontrib><creatorcontrib>Park, Young-Hwan</creatorcontrib><creatorcontrib>Park, Han Ki</creatorcontrib><title>Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair</title><title>Journal of chest surgery</title><addtitle>Korean J Thorac Cardiovasc Surg</addtitle><description>A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output.</description><subject>Aortic coarctation</subject><subject>Case Report</subject><subject>Hypoplastic left heart syndrome</subject><subject>Pulmonary hypertension</subject><subject>Shunts</subject><subject>흉부외과학</subject><issn>2233-601X</issn><issn>2765-1606</issn><issn>2093-6516</issn><issn>2765-1614</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVks1qGzEUhYfS0oQ0T1Ao2nYxU_2MNKNNwTVJYzBtSFLoTtzRSLY89shIcsDvkoetbKch0eaKq3O-K4lTFJ8JrjiW-NuwSjpWFBNZcVrVFWX0XXFOsWSl4ES8z3vK8h6Tv2fFZYwrnJfAlDfNx-KMkRozTOV58XS1MWFhRr1Ht7v1xo8Q9mgSkgn7Mvnyfh-T2Tj93EL3y92YUPLoRzAwoLQ06NZHl9yjQdfG9B3oAc293yJvEbxC3uy3JiPGeFBOg4suIrCZiX6ZrEiwRlMPQSdIzo_ozmzBhU_FBwvraC6f60Xx5_rqYXpTzn__nE0n81Iz1tCyboTlogWQdS2p0L3sGO45E0RybaWQXPKut8A1sKYTnWAcJNM2_xNpsSDsovh64o7BqkE75cEd68KrIajJ3cNMcclaRg7a2Unbe1ipbXCb_Lyj4djwYaEgJKfXRmFo6t7K1uZSN6Ru2zyPWGE09LbnNLO-n1jbXbcxvTZjCrB-A317MrplvtOjEqJtcC0ygJ0AOvgYg7EvXoLVISfqmBN1yIniVNUq5yS7vrwe--L5nwr2DzIYvRg</recordid><startdate>20190801</startdate><enddate>20190801</enddate><creator>Shin, Yu Rim</creator><creator>Yang, Young Ho</creator><creator>Park, Young-Hwan</creator><creator>Park, Han Ki</creator><general>The Korean Society for Thoracic and Cardiovascular Surgery</general><general>Korean Society for Thoracic and Cardiovascular Surgery</general><general>대한흉부외과학회</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope><scope>DOA</scope><scope>ACYCR</scope><orcidid>https://orcid.org/0000-0002-0977-0525</orcidid><orcidid>https://orcid.org/0000-0002-7472-7822</orcidid><orcidid>https://orcid.org/0000-0001-7685-0018</orcidid><orcidid>https://orcid.org/0000-0001-9802-8017</orcidid></search><sort><creationdate>20190801</creationdate><title>Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair</title><author>Shin, Yu Rim ; Yang, Young Ho ; Park, Young-Hwan ; Park, Han Ki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3372-476f568aa944926cd9b30d536195cf969595bdfa5ca37b6b635a93cf516180613</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Aortic coarctation</topic><topic>Case Report</topic><topic>Hypoplastic left heart syndrome</topic><topic>Pulmonary hypertension</topic><topic>Shunts</topic><topic>흉부외과학</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shin, Yu Rim</creatorcontrib><creatorcontrib>Yang, Young Ho</creatorcontrib><creatorcontrib>Park, Young-Hwan</creatorcontrib><creatorcontrib>Park, Han Ki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><collection>Korean Citation Index (Open Access)</collection><jtitle>Journal of chest surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shin, Yu Rim</au><au>Yang, Young Ho</au><au>Park, Young-Hwan</au><au>Park, Han Ki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair</atitle><jtitle>Journal of chest surgery</jtitle><addtitle>Korean J Thorac Cardiovasc Surg</addtitle><date>2019-08-01</date><risdate>2019</risdate><volume>52</volume><issue>4</issue><spage>232</spage><epage>235</epage><pages>232-235</pages><issn>2233-601X</issn><issn>2765-1606</issn><eissn>2093-6516</eissn><eissn>2765-1614</eissn><abstract>A 2.5-kg neonate with coarctation of the aorta and a small left ventricle experienced a severe pulmonary hypertensive crisis. An emergency pulmonary artery-to-systemic artery shunt was placed to break the positive feedback loop caused by pulmonary hypertension and functional mitral stenosis. This shunt provided immediate relief of suprasystemic pulmonary hypertension and the resultant low cardiac output.</abstract><cop>Korea (South)</cop><pub>The Korean Society for Thoracic and Cardiovascular Surgery</pub><pmid>31403029</pmid><doi>10.5090/kjtcs.2019.52.4.232</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0002-0977-0525</orcidid><orcidid>https://orcid.org/0000-0002-7472-7822</orcidid><orcidid>https://orcid.org/0000-0001-7685-0018</orcidid><orcidid>https://orcid.org/0000-0001-9802-8017</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2233-601X |
ispartof | Journal of Chest Surgery, 2019, 52(4), , pp.232-235 |
issn | 2233-601X 2765-1606 2093-6516 2765-1614 |
language | eng |
recordid | cdi_nrf_kci_oai_kci_go_kr_ARTI_5938311 |
source | PubMed Central; Directory of Open Access Journals |
subjects | Aortic coarctation Case Report Hypoplastic left heart syndrome Pulmonary hypertension Shunts 흉부외과학 |
title | Emergency Pulmonary Artery-to-Systemic Artery Shunt to Break the Positive Feedback Loop of a Pulmonary Hypertensive Crisis after Neonatal Coarctation Repair |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T16%3A15%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_nrf_k&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Emergency%20Pulmonary%20Artery-to-Systemic%20Artery%20Shunt%20to%20Break%20the%20Positive%20Feedback%20Loop%20of%20a%20Pulmonary%20Hypertensive%20Crisis%20after%20Neonatal%20Coarctation%20Repair&rft.jtitle=Journal%20of%20chest%20surgery&rft.au=Shin,%20Yu%20Rim&rft.date=2019-08-01&rft.volume=52&rft.issue=4&rft.spage=232&rft.epage=235&rft.pages=232-235&rft.issn=2233-601X&rft.eissn=2093-6516&rft_id=info:doi/10.5090/kjtcs.2019.52.4.232&rft_dat=%3Cpubmed_nrf_k%3E31403029%3C/pubmed_nrf_k%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3372-476f568aa944926cd9b30d536195cf969595bdfa5ca37b6b635a93cf516180613%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/31403029&rfr_iscdi=true |