Displacement of Surgical Clips in Patients with Human Acellular Dermal Matrix in the Excision Cavity during Whole Breast Irradiation Following Breast-Conserving Surgery
The purpose of this study was to investigate the displacement of surgical clips in the excision cavity during whole breast irradiation following breast-conserving surgery (BCS) with or without acellular dermal matrix (ADM) insertion, and to analyze clinicopathologic factors associated with the displ...
Saved in:
Published in: | Cancer research and treatment 2020, 52(2), , pp.388-395 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The purpose of this study was to investigate the displacement of surgical clips in the excision cavity during whole breast irradiation following breast-conserving surgery (BCS) with or without acellular dermal matrix (ADM) insertion, and to analyze clinicopathologic factors associated with the displacement of surgical clips.
From 2016 to 2017, 100 consecutive breast cancer patients who underwent BCS with the placement of surgical clips (superior, inferior, medial, lateral, and deep sides) in the tumor bed were included in this study. All patients took first planning computed tomography (CT) scan (CT 1) before whole breast irradiation and second CT scan (CT 2) before boost irradiation. Between two sets of planning CT, the displacement of surgical clips was calculated from the ΔX (lateral-medial), ΔY (anterior-posterior), ΔZ (superior-inferior), and three-dimensional (3D) directions. Patients were divided into two groups according to the breast volume replacement with ADM: group A with ADM and group B without ADM.
The means and 1 standard deviations of 3D displacement for superior, inferior, medial, lateral and deep clips were 5.2±2.9, 5.2±3.2, 5.6±4.5, 5.6±4.3, and 4.9±4.9 mm in entire cohort (n=100); 5.6±2.6, 6.0±3.5, 6.7±5.8, 6.7±5.7, and 6.1±7.4 mm in group A (n=38); 4.9±3.1, 4.8±3.0, 5.0±3.5, 5.0±2.9, and 4.3±2.8 mm in group B (n=62), respectively. The 3D displacements of group A were longer than those of group B, but only significant difference was observed in lateral clip (p=0.047).
This study demonstrated displacement of surgical clips during whole breast irradiation in patients with ADM insertion. For patients who had breast volume replacement using ADM, adaptive boost planning should be considered. |
---|---|