Loading…

Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography

This study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and method...

Full description

Saved in:
Bibliographic Details
Published in:The journal of advanced prosthodontics 2022, 14(1), 68, pp.45-55
Main Authors: Katheng, Awutsadaporn, Kanazawa, Manabu, Komagamine, Yuriko, Iwaki, Maiko, Namano, Sahaprom, Minakuchi, Shunsuke
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483
cites cdi_FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483
container_end_page 55
container_issue 1
container_start_page 45
container_title The journal of advanced prosthodontics
container_volume 14
creator Katheng, Awutsadaporn
Kanazawa, Manabu
Komagamine, Yuriko
Iwaki, Maiko
Namano, Sahaprom
Minakuchi, Shunsuke
description This study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α < .05). The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group ( < .05). For precision, this was significantly different from those of other groups ( < .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.
doi_str_mv 10.4047/jap.2022.14.1.45
format article
fullrecord <record><control><sourceid>proquest_nrf_k</sourceid><recordid>TN_cdi_nrf_kci_oai_kci_go_kr_ARTI_9931662</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2638946624</sourcerecordid><originalsourceid>FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483</originalsourceid><addsrcrecordid>eNpVkUFvFSEUhYnR2KZ278qw1MWMwAADG5OmqdqkiYmpa8Iw8B7tDIzAaN6_l-mrL8rm3ly-cy7kAPAWo5Yi2n980EtLECEtpi1uKXsBzglCrOkFpi9PPeJn4DLnB1QPpT1i_DU46xgRFDF8DtyNc9YUGB1cYi5N8iH7sIPFzxbqMMLZln0cYQxQG7MmbQ4bO9pQ1mThoLOFsw6r02YbjPC3L3uYi002TrWNu6SX_eENeOX0lO3lc70APz7f3F9_be6-fbm9vrprDO1QaRh3g-udGMkoHDcEC8ol4Vx23I6UDbg3tJJOao6Nc8b2A9NMStb3ndZUdBfgw9E3JKcejVdR-6e6i-oxqavv97dKyg5zTir76cgu6zDb0dQvJT2pJflZp8OT8v-b4PfV55cSQmIuNoP3zwYp_lxtLmr22dhp0sHGNSvCOyFpXUUrio6oSTHnZN1pDUZqS1PVNNWWpsJUYUVZlbz793knwd_suj-xOZ1R</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2638946624</pqid></control><display><type>article</type><title>Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography</title><source>PMC (PubMed Central)</source><creator>Katheng, Awutsadaporn ; Kanazawa, Manabu ; Komagamine, Yuriko ; Iwaki, Maiko ; Namano, Sahaprom ; Minakuchi, Shunsuke</creator><creatorcontrib>Katheng, Awutsadaporn ; Kanazawa, Manabu ; Komagamine, Yuriko ; Iwaki, Maiko ; Namano, Sahaprom ; Minakuchi, Shunsuke</creatorcontrib><description>This study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α &lt; .05). The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group ( &lt; .05). For precision, this was significantly different from those of other groups ( &lt; .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.</description><identifier>ISSN: 2005-7806</identifier><identifier>EISSN: 2005-7814</identifier><identifier>DOI: 10.4047/jap.2022.14.1.45</identifier><identifier>PMID: 35284051</identifier><language>eng</language><publisher>Korea (South): The Korean Academy of Prosthodontics</publisher><subject>Original ; 치의학</subject><ispartof>The Journal of Advanced of Prosthodontics, 2022, 14(1), 68, pp.45-55</ispartof><rights>2022 The Korean Academy of Prosthodontics.</rights><rights>2022 The Korean Academy of Prosthodontics 2022 The Korean Academy of Prosthodontics</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483</citedby><cites>FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483</cites><orcidid>0000-0003-2217-7539 ; 0000-0003-3703-7627 ; 0000-0003-1832-8621 ; 0000-0003-2587-5455 ; 0000-0001-8769-5121 ; 0000-0001-5326-9482</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8891682/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8891682/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/35284051$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002811898$$DAccess content in National Research Foundation of Korea (NRF)$$Hfree_for_read</backlink></links><search><creatorcontrib>Katheng, Awutsadaporn</creatorcontrib><creatorcontrib>Kanazawa, Manabu</creatorcontrib><creatorcontrib>Komagamine, Yuriko</creatorcontrib><creatorcontrib>Iwaki, Maiko</creatorcontrib><creatorcontrib>Namano, Sahaprom</creatorcontrib><creatorcontrib>Minakuchi, Shunsuke</creatorcontrib><title>Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography</title><title>The journal of advanced prosthodontics</title><addtitle>J Adv Prosthodont</addtitle><description>This study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α &lt; .05). The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group ( &lt; .05). For precision, this was significantly different from those of other groups ( &lt; .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.</description><subject>Original</subject><subject>치의학</subject><issn>2005-7806</issn><issn>2005-7814</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNpVkUFvFSEUhYnR2KZ278qw1MWMwAADG5OmqdqkiYmpa8Iw8B7tDIzAaN6_l-mrL8rm3ly-cy7kAPAWo5Yi2n980EtLECEtpi1uKXsBzglCrOkFpi9PPeJn4DLnB1QPpT1i_DU46xgRFDF8DtyNc9YUGB1cYi5N8iH7sIPFzxbqMMLZln0cYQxQG7MmbQ4bO9pQ1mThoLOFsw6r02YbjPC3L3uYi002TrWNu6SX_eENeOX0lO3lc70APz7f3F9_be6-fbm9vrprDO1QaRh3g-udGMkoHDcEC8ol4Vx23I6UDbg3tJJOao6Nc8b2A9NMStb3ndZUdBfgw9E3JKcejVdR-6e6i-oxqavv97dKyg5zTir76cgu6zDb0dQvJT2pJflZp8OT8v-b4PfV55cSQmIuNoP3zwYp_lxtLmr22dhp0sHGNSvCOyFpXUUrio6oSTHnZN1pDUZqS1PVNNWWpsJUYUVZlbz793knwd_suj-xOZ1R</recordid><startdate>20220201</startdate><enddate>20220201</enddate><creator>Katheng, Awutsadaporn</creator><creator>Kanazawa, Manabu</creator><creator>Komagamine, Yuriko</creator><creator>Iwaki, Maiko</creator><creator>Namano, Sahaprom</creator><creator>Minakuchi, Shunsuke</creator><general>The Korean Academy of Prosthodontics</general><general>대한치과보철학회</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>ACYCR</scope><orcidid>https://orcid.org/0000-0003-2217-7539</orcidid><orcidid>https://orcid.org/0000-0003-3703-7627</orcidid><orcidid>https://orcid.org/0000-0003-1832-8621</orcidid><orcidid>https://orcid.org/0000-0003-2587-5455</orcidid><orcidid>https://orcid.org/0000-0001-8769-5121</orcidid><orcidid>https://orcid.org/0000-0001-5326-9482</orcidid></search><sort><creationdate>20220201</creationdate><title>Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography</title><author>Katheng, Awutsadaporn ; Kanazawa, Manabu ; Komagamine, Yuriko ; Iwaki, Maiko ; Namano, Sahaprom ; Minakuchi, Shunsuke</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Original</topic><topic>치의학</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Katheng, Awutsadaporn</creatorcontrib><creatorcontrib>Kanazawa, Manabu</creatorcontrib><creatorcontrib>Komagamine, Yuriko</creatorcontrib><creatorcontrib>Iwaki, Maiko</creatorcontrib><creatorcontrib>Namano, Sahaprom</creatorcontrib><creatorcontrib>Minakuchi, Shunsuke</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Korean Citation Index</collection><jtitle>The journal of advanced prosthodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Katheng, Awutsadaporn</au><au>Kanazawa, Manabu</au><au>Komagamine, Yuriko</au><au>Iwaki, Maiko</au><au>Namano, Sahaprom</au><au>Minakuchi, Shunsuke</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography</atitle><jtitle>The journal of advanced prosthodontics</jtitle><addtitle>J Adv Prosthodont</addtitle><date>2022-02-01</date><risdate>2022</risdate><volume>14</volume><issue>1</issue><spage>45</spage><epage>55</epage><pages>45-55</pages><issn>2005-7806</issn><eissn>2005-7814</eissn><abstract>This study investigates the effect of different post-rinsing times and methods on the trueness and precision of denture base resin manufactured through stereolithography. Ninety clear photopolymer resin specimens were fabricated and divided into nine groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5, 10, and 15 min using three methods-automated, ultrasonic cleaning, and hand washing. The specimens were polymerized for 30 min at 40℃. For trueness, the scanned intaglio surface of each SLA denture base was superimposed on the original standard tessellation language (STL) file using best-fit alignment (n = 10). For precision, the scanned intaglio surface of the STL file in each specimen group was superimposed across each specimen (n = 45). The root mean square error (RMSE) was measured, and the data were analyzed statistically through one-way ANOVA and Tukey test (α &lt; .05). The 10-min automated group exhibited the lowest RMSE. For trueness, this was significantly different from specimens in the 5-min hand-washed group ( &lt; .05). For precision, this was significantly different from those of other groups ( &lt; .05), except for the 15-min automated and 15-min ultrasonic groups. The color map results indicated that the 10-min automated method exhibited the most uniform distribution of the intaglio surface adaptation. The optimal postprocessing rinsing times and methods for achieving clear photopolymer resin were found to be the automated method with rinsing times of 10 and 15 min, and the ultrasonic method with a rinsing time of 15 min.</abstract><cop>Korea (South)</cop><pub>The Korean Academy of Prosthodontics</pub><pmid>35284051</pmid><doi>10.4047/jap.2022.14.1.45</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-2217-7539</orcidid><orcidid>https://orcid.org/0000-0003-3703-7627</orcidid><orcidid>https://orcid.org/0000-0003-1832-8621</orcidid><orcidid>https://orcid.org/0000-0003-2587-5455</orcidid><orcidid>https://orcid.org/0000-0001-8769-5121</orcidid><orcidid>https://orcid.org/0000-0001-5326-9482</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2005-7806
ispartof The Journal of Advanced of Prosthodontics, 2022, 14(1), 68, pp.45-55
issn 2005-7806
2005-7814
language eng
recordid cdi_nrf_kci_oai_kci_go_kr_ARTI_9931662
source PMC (PubMed Central)
subjects Original
치의학
title Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T21%3A37%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_nrf_k&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20post-rinsing%20time%20and%20method%20on%20accuracy%20of%20denture%20base%20manufactured%20with%20stereolithography&rft.jtitle=The%20journal%20of%20advanced%20prosthodontics&rft.au=Katheng,%20Awutsadaporn&rft.date=2022-02-01&rft.volume=14&rft.issue=1&rft.spage=45&rft.epage=55&rft.pages=45-55&rft.issn=2005-7806&rft.eissn=2005-7814&rft_id=info:doi/10.4047/jap.2022.14.1.45&rft_dat=%3Cproquest_nrf_k%3E2638946624%3C/proquest_nrf_k%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c430t-56fbf7f8d2d8f6c218469266936ed45b17c4c43f9a61cffce7b5a5995773aa483%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2638946624&rft_id=info:pmid/35284051&rfr_iscdi=true