Loading…
Experimental Results with Fuel Cell Start-up and Shut-down. Impact of Type of Carbon for Cathode Catalyst Support
Separate testing protocols for fuel cell startups and shutdowns were developed to distinguish between their effects on reverse currents and CO 2 evolution. The internal currents and the local potentials were measured with different membrane-electrode assemblies (MEAs): we examined the influence of t...
Saved in:
Published in: | ECS transactions 2015, Vol.69 (17), p.1065-1074 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Separate testing protocols for fuel cell startups and shutdowns were developed to distinguish between their effects on reverse currents and CO
2
evolution. The internal currents and the local potentials were measured with different membrane-electrode assemblies (MEAs): we examined the influence of the type of carbon for cathode catalyst support as well as the mitigating effect of low anode Pt loading. Significant differences were observed and the experiments also confirmed previous results that the evolved CO
2
accounts for less than 25% of the total exchanged charge. |
---|---|
ISSN: | 1938-5862 1938-6737 1938-6737 |
DOI: | 10.1149/06917.1065ecst |