Loading…

A humidity-controlled fast integrated mobility spectrometer (HFIMS) for rapid measurements of particle hygroscopic growth

We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et...

Full description

Saved in:
Bibliographic Details
Published in:Atmospheric measurement techniques 2017-12, Vol.10 (12)
Main Authors: Pinterich, Tamara, Spielman, Steven R., Wang, Yang, Hering, Susanne V., Wang, Jian
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present a Humidity-controlled Fast Integrated Mobility Spectrometer (HFIMS) for rapid particle hygroscopicity measurements. The HFIMS consists of a differential mobility analyzer (DMA), a relative humidity (RH) control unit and a water-based FIMS (WFIMS) coupled in series. The WFIMS (Pinterich et al., 2017) combines the Fast Integrated Mobility Spectrometer (Kulkarni and Wang, 2006a, b) with laminar flow water condensation methodologies (Hering & Stolzenburg 2005; Spielman et al. 2017). Inside the WFIMS, particles of different electrical mobilities are spatially separated in an electric field, condensationally enlarged and imaged to provide 1-Hz measurements of size distribution spanning a factor of ~3 in particle diameter, sufficient to cover the entire range of growth factor for atmopheric aerosol particles at 90 % RH. By replacing the second DMA of a traditional hygroscopicity tandem DMA (HTDMA) system with the WFIMS, the HFIMS greatly increases the speed of particle growth factor measurement. The performance of the HFIMS was evaluated using NaCl particles with well-known hygroscopic growth behavior, and further through measurements of ambient aerosols. Results show that HFIMS can reproduce, within 2 % the literature values for hygroscopic growth of NaCl particles. NaCl deliquescence was observed between 76 % and 77 % RH in agreement with the theoretical value of 76.5 % (Ming and Russell, 2001), and efflorescence relative humidity (43 %) was found to lie within the RH range of 41 % to 56 % reported in the literature. Ambient data indicate that HFIMS can measure the hygroscopic growth of five standard dry particle sizes ranging from 35 to 165 nm within less than three minutes, which makes it about an order of magnitude faster than traditional HTDMA systems.
ISSN:1867-8548
1867-8548
DOI:10.5194/amt-10-4915-2017