Cognitive barriers during monitoring-based commissioning of buildings

•Monitoring-based commissioning (MBCx) can help optimize energy performance in buildings.•However, many buildings with MBCx still underperform due to cognitive and operational barriers.•Most frequently occurring cognitive barrier among 40 public and private organizations was risk aversion.•Choice ar...

Full description

Saved in:
Bibliographic Details
Published in:Sustainable cities and society 2019-04, Vol.46 (C), p.101389, Article 101389
Main Authors: Harris, Nora, Shealy, Tripp, Parrish, Kristen, Granderson, Jessica
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13
cites cdi_FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13
container_end_page
container_issue C
container_start_page 101389
container_title Sustainable cities and society
container_volume 46
creator Harris, Nora
Shealy, Tripp
Parrish, Kristen
Granderson, Jessica
description •Monitoring-based commissioning (MBCx) can help optimize energy performance in buildings.•However, many buildings with MBCx still underperform due to cognitive and operational barriers.•Most frequently occurring cognitive barrier among 40 public and private organizations was risk aversion.•Choice architecture is offered as a solution to overcome cognitive barriers. Monitoring-based commissioning (MBCx) is a continuous building energy management process used to optimize energy performance in buildings. Although monitoring-based commissioning (MBCx) can reduce energy waste by up to 20%, many buildings still underperform due to issues such as unnoticed system faults and inefficient operational procedures. While there are technical barriers that impede the MBCx process, such as data quality, the focuses of this paper are the non-technical, behavioral and organizational, barriers that contribute to issues initiating and implementing MBCx. In particular, this paper discusses cognitive biases, which can lead to suboptimal outcomes in energy efficiency decisions, resulting in missed opportunities for energy savings. This paper provides evidence of cognitive biases in decisions during the MBCx process using qualitative data from over 40 public and private sector organizations. The results describe barriers resulting from cognitive biases, listed in descending order of occurrence, including: risk aversion, social norms, choice overload, status quo bias, information overload, professional bias, and temporal discounting. Building practitioners can use these results to better understand potential cognitive biases, in turn allowing them to establish best practices and make more informed decisions. Researchers can use these results to empirically test specific decision interventions and facilitate more energy efficient decisions.
doi_str_mv 10.1016/j.scs.2018.12.017
format article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1607405</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2210670718304426</els_id><sourcerecordid>S2210670718304426</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13</originalsourceid><addsrcrecordid>eNp9UEtLxDAQDqLgsu4P8Fa8t2bSpmnxJGV9wIIXPYe8uqZsG8l0F_z3pqx4dC7zMd-D4SPkFmgBFOr7oUCDBaPQFMAKCuKCrBgDmtcC-OUfpuKabBAHmobX0FZ8RbZd2E9-9ieXaRWjdxEze4x-2mdjSERYYK4VOpuZMI4e0ad7okOf6aM_2ITxhlz16oBu87vX5ONp-9695Lu359fucZebitE5t1w5zRtWNS1lwJjqrTCVFbWtdcU0a1VpBNOaMq5Lq5qWl30rLOetAaEclGtyd84NOHuJxs_OfJowTc7MEmoqKsqTCM4iEwNidL38in5U8VsClUtfckhWlEtfEphMfSXPw9nj0ven1MIS7ibjrI9Ltg3-H_cP7SxzSg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Cognitive barriers during monitoring-based commissioning of buildings</title><source>ScienceDirect Journals</source><creator>Harris, Nora ; Shealy, Tripp ; Parrish, Kristen ; Granderson, Jessica</creator><creatorcontrib>Harris, Nora ; Shealy, Tripp ; Parrish, Kristen ; Granderson, Jessica ; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><description>•Monitoring-based commissioning (MBCx) can help optimize energy performance in buildings.•However, many buildings with MBCx still underperform due to cognitive and operational barriers.•Most frequently occurring cognitive barrier among 40 public and private organizations was risk aversion.•Choice architecture is offered as a solution to overcome cognitive barriers. Monitoring-based commissioning (MBCx) is a continuous building energy management process used to optimize energy performance in buildings. Although monitoring-based commissioning (MBCx) can reduce energy waste by up to 20%, many buildings still underperform due to issues such as unnoticed system faults and inefficient operational procedures. While there are technical barriers that impede the MBCx process, such as data quality, the focuses of this paper are the non-technical, behavioral and organizational, barriers that contribute to issues initiating and implementing MBCx. In particular, this paper discusses cognitive biases, which can lead to suboptimal outcomes in energy efficiency decisions, resulting in missed opportunities for energy savings. This paper provides evidence of cognitive biases in decisions during the MBCx process using qualitative data from over 40 public and private sector organizations. The results describe barriers resulting from cognitive biases, listed in descending order of occurrence, including: risk aversion, social norms, choice overload, status quo bias, information overload, professional bias, and temporal discounting. Building practitioners can use these results to better understand potential cognitive biases, in turn allowing them to establish best practices and make more informed decisions. Researchers can use these results to empirically test specific decision interventions and facilitate more energy efficient decisions.</description><identifier>ISSN: 2210-6707</identifier><identifier>EISSN: 2210-6715</identifier><identifier>DOI: 10.1016/j.scs.2018.12.017</identifier><language>eng</language><publisher>United States: Elsevier Ltd</publisher><subject>Behavioral decision science ; Cognitive biases ; Energy management and information systems ; ENERGY PLANNING, POLICY, AND ECONOMY ; Monitoring-based commissioning ; Risk aversion</subject><ispartof>Sustainable cities and society, 2019-04, Vol.46 (C), p.101389, Article 101389</ispartof><rights>2019 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13</citedby><cites>FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13</cites><orcidid>0000-0002-4255-3266 ; 0000000242553266</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.osti.gov/servlets/purl/1607405$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Harris, Nora</creatorcontrib><creatorcontrib>Shealy, Tripp</creatorcontrib><creatorcontrib>Parrish, Kristen</creatorcontrib><creatorcontrib>Granderson, Jessica</creatorcontrib><creatorcontrib>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><title>Cognitive barriers during monitoring-based commissioning of buildings</title><title>Sustainable cities and society</title><description>•Monitoring-based commissioning (MBCx) can help optimize energy performance in buildings.•However, many buildings with MBCx still underperform due to cognitive and operational barriers.•Most frequently occurring cognitive barrier among 40 public and private organizations was risk aversion.•Choice architecture is offered as a solution to overcome cognitive barriers. Monitoring-based commissioning (MBCx) is a continuous building energy management process used to optimize energy performance in buildings. Although monitoring-based commissioning (MBCx) can reduce energy waste by up to 20%, many buildings still underperform due to issues such as unnoticed system faults and inefficient operational procedures. While there are technical barriers that impede the MBCx process, such as data quality, the focuses of this paper are the non-technical, behavioral and organizational, barriers that contribute to issues initiating and implementing MBCx. In particular, this paper discusses cognitive biases, which can lead to suboptimal outcomes in energy efficiency decisions, resulting in missed opportunities for energy savings. This paper provides evidence of cognitive biases in decisions during the MBCx process using qualitative data from over 40 public and private sector organizations. The results describe barriers resulting from cognitive biases, listed in descending order of occurrence, including: risk aversion, social norms, choice overload, status quo bias, information overload, professional bias, and temporal discounting. Building practitioners can use these results to better understand potential cognitive biases, in turn allowing them to establish best practices and make more informed decisions. Researchers can use these results to empirically test specific decision interventions and facilitate more energy efficient decisions.</description><subject>Behavioral decision science</subject><subject>Cognitive biases</subject><subject>Energy management and information systems</subject><subject>ENERGY PLANNING, POLICY, AND ECONOMY</subject><subject>Monitoring-based commissioning</subject><subject>Risk aversion</subject><issn>2210-6707</issn><issn>2210-6715</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9UEtLxDAQDqLgsu4P8Fa8t2bSpmnxJGV9wIIXPYe8uqZsG8l0F_z3pqx4dC7zMd-D4SPkFmgBFOr7oUCDBaPQFMAKCuKCrBgDmtcC-OUfpuKabBAHmobX0FZ8RbZd2E9-9ieXaRWjdxEze4x-2mdjSERYYK4VOpuZMI4e0ad7okOf6aM_2ITxhlz16oBu87vX5ONp-9695Lu359fucZebitE5t1w5zRtWNS1lwJjqrTCVFbWtdcU0a1VpBNOaMq5Lq5qWl30rLOetAaEclGtyd84NOHuJxs_OfJowTc7MEmoqKsqTCM4iEwNidL38in5U8VsClUtfckhWlEtfEphMfSXPw9nj0ven1MIS7ibjrI9Ltg3-H_cP7SxzSg</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Harris, Nora</creator><creator>Shealy, Tripp</creator><creator>Parrish, Kristen</creator><creator>Granderson, Jessica</creator><general>Elsevier Ltd</general><general>Elseiver</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OIOZB</scope><scope>OTOTI</scope><orcidid>https://orcid.org/0000-0002-4255-3266</orcidid><orcidid>https://orcid.org/0000000242553266</orcidid></search><sort><creationdate>20190401</creationdate><title>Cognitive barriers during monitoring-based commissioning of buildings</title><author>Harris, Nora ; Shealy, Tripp ; Parrish, Kristen ; Granderson, Jessica</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Behavioral decision science</topic><topic>Cognitive biases</topic><topic>Energy management and information systems</topic><topic>ENERGY PLANNING, POLICY, AND ECONOMY</topic><topic>Monitoring-based commissioning</topic><topic>Risk aversion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Harris, Nora</creatorcontrib><creatorcontrib>Shealy, Tripp</creatorcontrib><creatorcontrib>Parrish, Kristen</creatorcontrib><creatorcontrib>Granderson, Jessica</creatorcontrib><creatorcontrib>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV - Hybrid</collection><collection>OSTI.GOV</collection><jtitle>Sustainable cities and society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harris, Nora</au><au>Shealy, Tripp</au><au>Parrish, Kristen</au><au>Granderson, Jessica</au><aucorp>Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cognitive barriers during monitoring-based commissioning of buildings</atitle><jtitle>Sustainable cities and society</jtitle><date>2019-04-01</date><risdate>2019</risdate><volume>46</volume><issue>C</issue><spage>101389</spage><pages>101389-</pages><artnum>101389</artnum><issn>2210-6707</issn><eissn>2210-6715</eissn><abstract>•Monitoring-based commissioning (MBCx) can help optimize energy performance in buildings.•However, many buildings with MBCx still underperform due to cognitive and operational barriers.•Most frequently occurring cognitive barrier among 40 public and private organizations was risk aversion.•Choice architecture is offered as a solution to overcome cognitive barriers. Monitoring-based commissioning (MBCx) is a continuous building energy management process used to optimize energy performance in buildings. Although monitoring-based commissioning (MBCx) can reduce energy waste by up to 20%, many buildings still underperform due to issues such as unnoticed system faults and inefficient operational procedures. While there are technical barriers that impede the MBCx process, such as data quality, the focuses of this paper are the non-technical, behavioral and organizational, barriers that contribute to issues initiating and implementing MBCx. In particular, this paper discusses cognitive biases, which can lead to suboptimal outcomes in energy efficiency decisions, resulting in missed opportunities for energy savings. This paper provides evidence of cognitive biases in decisions during the MBCx process using qualitative data from over 40 public and private sector organizations. The results describe barriers resulting from cognitive biases, listed in descending order of occurrence, including: risk aversion, social norms, choice overload, status quo bias, information overload, professional bias, and temporal discounting. Building practitioners can use these results to better understand potential cognitive biases, in turn allowing them to establish best practices and make more informed decisions. Researchers can use these results to empirically test specific decision interventions and facilitate more energy efficient decisions.</abstract><cop>United States</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.scs.2018.12.017</doi><orcidid>https://orcid.org/0000-0002-4255-3266</orcidid><orcidid>https://orcid.org/0000000242553266</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2210-6707
ispartof Sustainable cities and society, 2019-04, Vol.46 (C), p.101389, Article 101389
issn 2210-6707
2210-6715
language eng
recordid cdi_osti_scitechconnect_1607405
source ScienceDirect Journals
subjects Behavioral decision science
Cognitive biases
Energy management and information systems
ENERGY PLANNING, POLICY, AND ECONOMY
Monitoring-based commissioning
Risk aversion
title Cognitive barriers during monitoring-based commissioning of buildings
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T14%3A07%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cognitive%20barriers%20during%20monitoring-based%20commissioning%20of%20buildings&rft.jtitle=Sustainable%20cities%20and%20society&rft.au=Harris,%20Nora&rft.aucorp=Lawrence%20Berkeley%20National%20Lab.%20(LBNL),%20Berkeley,%20CA%20(United%20States)&rft.date=2019-04-01&rft.volume=46&rft.issue=C&rft.spage=101389&rft.pages=101389-&rft.artnum=101389&rft.issn=2210-6707&rft.eissn=2210-6715&rft_id=info:doi/10.1016/j.scs.2018.12.017&rft_dat=%3Celsevier_osti_%3ES2210670718304426%3C/elsevier_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-d5aeb58248902122afd7c4d76d6b42b29a3c72bb025b3da8953f97d559c17ae13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true