Loading…

Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis

Calcium looping (CaL) systems have been proposed as a lower-cost method of CO2 capture for power plants. This paper presents the results of a techno-economic assessment of a CaL system for post-combustion CO2 capture at a pulverized coal (PC) power plant. Comparisons are made with a conventional MEA...

Full description

Saved in:
Bibliographic Details
Published in:Energy procedia 2014, Vol.63 (C), p.2199-2206
Main Authors: Mantripragada, Hari C., Rubin, Edward S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13
cites cdi_FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13
container_end_page 2206
container_issue C
container_start_page 2199
container_title Energy procedia
container_volume 63
creator Mantripragada, Hari C.
Rubin, Edward S.
description Calcium looping (CaL) systems have been proposed as a lower-cost method of CO2 capture for power plants. This paper presents the results of a techno-economic assessment of a CaL system for post-combustion CO2 capture at a pulverized coal (PC) power plant. Comparisons are made with a conventional MEA-based CO2 capture process in terms of performance and cost. Considering the significant quantities of solid flows required for a CaL process, the applicability and operational feasibility of a CaL system for new or existing PC power plants also is studied. It was found that though the CaL system has better performance than the MEA-based CO2 capture process, the capital cost of the power plant and the cost of electricity is much higher than when the MEA-based system is used.
doi_str_mv 10.1016/j.egypro.2014.11.239
format article
fullrecord <record><control><sourceid>elsevier_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_1829146</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1876610214020542</els_id><sourcerecordid>S1876610214020542</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13</originalsourceid><addsrcrecordid>eNp9UMFKw0AQDaJgrf6Bh8WzjTPb7SbxIJRgVShUQc_LZjOpW9Ik7EYhf--GePDkaWYe7z3mvSi6RogRUN4dYtoPnWtjDihixJgvs5NohmkiFxKBn_7Zz6ML7w8ACUAqZtFbrmtjv45s27adbfYsH0xNrGody3ec5brrvxzds1dyATvqxtAty1vfs3VTsg1pbwtb234It64Hb_1ldFbp2tPV75xHH5vH9_x5sd09veTr7cIIDv0iTYTQUpRpQhkYkiRLXlQaCcAg5wmURRUAmWC2SgjKrDAihZWhwnAQGpfz6GbyDc9Y5Y3tyXyatmnI9ApTnqGQgSQmknGt944q1Tl71G5QCGrsTh3U1J0au1OIKnQXZA-TjEKAb0tu9KeQvbRutC9b-7_BD-f3eSQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis</title><source>ScienceDirect Journals</source><creator>Mantripragada, Hari C. ; Rubin, Edward S.</creator><creatorcontrib>Mantripragada, Hari C. ; Rubin, Edward S.</creatorcontrib><description>Calcium looping (CaL) systems have been proposed as a lower-cost method of CO2 capture for power plants. This paper presents the results of a techno-economic assessment of a CaL system for post-combustion CO2 capture at a pulverized coal (PC) power plant. Comparisons are made with a conventional MEA-based CO2 capture process in terms of performance and cost. Considering the significant quantities of solid flows required for a CaL process, the applicability and operational feasibility of a CaL system for new or existing PC power plants also is studied. It was found that though the CaL system has better performance than the MEA-based CO2 capture process, the capital cost of the power plant and the cost of electricity is much higher than when the MEA-based system is used.</description><identifier>ISSN: 1876-6102</identifier><identifier>EISSN: 1876-6102</identifier><identifier>DOI: 10.1016/j.egypro.2014.11.239</identifier><language>eng</language><publisher>Netherlands: Elsevier Ltd</publisher><subject>calcium looping ; CO2 capt ure ; post-combustion ; techno-economic analysis</subject><ispartof>Energy procedia, 2014, Vol.63 (C), p.2199-2206</ispartof><rights>2014 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13</citedby><cites>FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1876610214020542$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,780,784,885,3547,4022,27922,27923,27924,45779</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/1829146$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Mantripragada, Hari C.</creatorcontrib><creatorcontrib>Rubin, Edward S.</creatorcontrib><title>Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis</title><title>Energy procedia</title><description>Calcium looping (CaL) systems have been proposed as a lower-cost method of CO2 capture for power plants. This paper presents the results of a techno-economic assessment of a CaL system for post-combustion CO2 capture at a pulverized coal (PC) power plant. Comparisons are made with a conventional MEA-based CO2 capture process in terms of performance and cost. Considering the significant quantities of solid flows required for a CaL process, the applicability and operational feasibility of a CaL system for new or existing PC power plants also is studied. It was found that though the CaL system has better performance than the MEA-based CO2 capture process, the capital cost of the power plant and the cost of electricity is much higher than when the MEA-based system is used.</description><subject>calcium looping</subject><subject>CO2 capt ure</subject><subject>post-combustion</subject><subject>techno-economic analysis</subject><issn>1876-6102</issn><issn>1876-6102</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNp9UMFKw0AQDaJgrf6Bh8WzjTPb7SbxIJRgVShUQc_LZjOpW9Ik7EYhf--GePDkaWYe7z3mvSi6RogRUN4dYtoPnWtjDihixJgvs5NohmkiFxKBn_7Zz6ML7w8ACUAqZtFbrmtjv45s27adbfYsH0xNrGody3ec5brrvxzds1dyATvqxtAty1vfs3VTsg1pbwtb234It64Hb_1ldFbp2tPV75xHH5vH9_x5sd09veTr7cIIDv0iTYTQUpRpQhkYkiRLXlQaCcAg5wmURRUAmWC2SgjKrDAihZWhwnAQGpfz6GbyDc9Y5Y3tyXyatmnI9ApTnqGQgSQmknGt944q1Tl71G5QCGrsTh3U1J0au1OIKnQXZA-TjEKAb0tu9KeQvbRutC9b-7_BD-f3eSQ</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Mantripragada, Hari C.</creator><creator>Rubin, Edward S.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>2014</creationdate><title>Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis</title><author>Mantripragada, Hari C. ; Rubin, Edward S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>calcium looping</topic><topic>CO2 capt ure</topic><topic>post-combustion</topic><topic>techno-economic analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mantripragada, Hari C.</creatorcontrib><creatorcontrib>Rubin, Edward S.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Energy procedia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mantripragada, Hari C.</au><au>Rubin, Edward S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis</atitle><jtitle>Energy procedia</jtitle><date>2014</date><risdate>2014</risdate><volume>63</volume><issue>C</issue><spage>2199</spage><epage>2206</epage><pages>2199-2206</pages><issn>1876-6102</issn><eissn>1876-6102</eissn><abstract>Calcium looping (CaL) systems have been proposed as a lower-cost method of CO2 capture for power plants. This paper presents the results of a techno-economic assessment of a CaL system for post-combustion CO2 capture at a pulverized coal (PC) power plant. Comparisons are made with a conventional MEA-based CO2 capture process in terms of performance and cost. Considering the significant quantities of solid flows required for a CaL process, the applicability and operational feasibility of a CaL system for new or existing PC power plants also is studied. It was found that though the CaL system has better performance than the MEA-based CO2 capture process, the capital cost of the power plant and the cost of electricity is much higher than when the MEA-based system is used.</abstract><cop>Netherlands</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.egypro.2014.11.239</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1876-6102
ispartof Energy procedia, 2014, Vol.63 (C), p.2199-2206
issn 1876-6102
1876-6102
language eng
recordid cdi_osti_scitechconnect_1829146
source ScienceDirect Journals
subjects calcium looping
CO2 capt ure
post-combustion
techno-economic analysis
title Calcium Looping Cycle for CO2 Capture: Performance, Cost And Feasibility Analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T04%3A29%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calcium%20Looping%20Cycle%20for%20CO2%20Capture:%20Performance,%20Cost%20And%20Feasibility%20Analysis&rft.jtitle=Energy%20procedia&rft.au=Mantripragada,%20Hari%20C.&rft.date=2014&rft.volume=63&rft.issue=C&rft.spage=2199&rft.epage=2206&rft.pages=2199-2206&rft.issn=1876-6102&rft.eissn=1876-6102&rft_id=info:doi/10.1016/j.egypro.2014.11.239&rft_dat=%3Celsevier_osti_%3ES1876610214020542%3C/elsevier_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-8744a64d87e90ce6e6d2bfa1e00c12270dbf2bf671957e0d9bc4805cebc204a13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true