A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples

The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes (3He, 4He, 20Ne, 21Ne, 22Ne, 36Ar, 40Ar, 84Kr, 136Xe) and tritium (3H) from water samples are described. The 3H concentration is measured indirectly by the 3He ingrowth from radioactive decay. Af...

Full description

Saved in:
Bibliographic Details
Published in:Environmental science & technology 2000-05, Vol.34 (10), p.2042-2050
Main Authors: Beyerle, Urs, Aeschbach-Hertig, Werner, Imboden, Dieter M, Baur, Heinrich, Graf, Thomas, Kipfer, Rolf
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73
cites cdi_FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73
container_end_page 2050
container_issue 10
container_start_page 2042
container_title Environmental science & technology
container_volume 34
creator Beyerle, Urs
Aeschbach-Hertig, Werner
Imboden, Dieter M
Baur, Heinrich
Graf, Thomas
Kipfer, Rolf
description The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes (3He, 4He, 20Ne, 21Ne, 22Ne, 36Ar, 40Ar, 84Kr, 136Xe) and tritium (3H) from water samples are described. The 3H concentration is measured indirectly by the 3He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3He/4He, 20Ne/22Ne, and 40Ar/36Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20Ne/22Ne and 36Ar/40Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.
doi_str_mv 10.1021/es990840h
format article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_20080467</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>54890929</sourcerecordid><originalsourceid>FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73</originalsourceid><addsrcrecordid>eNpl0VFrFDEQB_BQFHpWH_wGQbHgw9pks7ndPB5HrdbaCne2xZcwzc5yqbubayYH3rc3ZaWCkoe8_GYy-Q9jr6X4IEUpT5CMEU0lNgdsJnUpCt1o-YzNhJCqMGp-e8heEN0LIUolmhn7seBfgYivtuhSDAOm6B1f7SnhwLsQedogX4zQ78kTDx2_DHc98jMgJA5jy9fRJ7_LNhfzG0gY-QqGbY_0kj3voCd89ec-Yt8_nq6Xn4qLq7PPy8VFAaqRqWhapSRWCsq2Ea0yGgB11c5rk4-CKo8p5B3I1oFy0sgOOgUNVqArDQZqdcTeTn0DJW_J-YRu48I45h_ZUuTyav6ojie1jeFhh5Ts4Mlh38OIYUdW1vNamFpm-OYfeB92MSdANkcmS6OUzuj9hFwMRBE7u41-gLi3UtjHRdinRWRbTNbnUH89QYg_bZ6r1nb9bWUv1fny_Lr-Ym-zfzd5cPT37f_7_gYuM5Rw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>230129335</pqid></control><display><type>article</type><title>A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Beyerle, Urs ; Aeschbach-Hertig, Werner ; Imboden, Dieter M ; Baur, Heinrich ; Graf, Thomas ; Kipfer, Rolf</creator><creatorcontrib>Beyerle, Urs ; Aeschbach-Hertig, Werner ; Imboden, Dieter M ; Baur, Heinrich ; Graf, Thomas ; Kipfer, Rolf ; Swiss Federal Inst. of Tech., Dubendorf (SE)</creatorcontrib><description>The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes (3He, 4He, 20Ne, 21Ne, 22Ne, 36Ar, 40Ar, 84Kr, 136Xe) and tritium (3H) from water samples are described. The 3H concentration is measured indirectly by the 3He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3He/4He, 20Ne/22Ne, and 40Ar/36Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20Ne/22Ne and 36Ar/40Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.</description><identifier>ISSN: 0013-936X</identifier><identifier>EISSN: 1520-5851</identifier><identifier>DOI: 10.1021/es990840h</identifier><identifier>CODEN: ESTHAG</identifier><language>eng</language><publisher>Easton: American Chemical Society</publisher><subject>ARGON 36 ; ARGON 40 ; Environmental monitoring ; ENVIRONMENTAL SCIENCES ; Freshwater ; Gases ; HELIUM 3 ; HELIUM 4 ; Isotopes ; KRYPTON 84 ; MASS SPECTROSCOPY ; NEON 21 ; NEON 22 ; TRITIUM ; WATER POLLUTION ; XENON 136</subject><ispartof>Environmental science &amp; technology, 2000-05, Vol.34 (10), p.2042-2050</ispartof><rights>Copyright © 2000 American Chemical Society</rights><rights>Copyright American Chemical Society May 15, 2000</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73</citedby><cites>FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/20080467$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Beyerle, Urs</creatorcontrib><creatorcontrib>Aeschbach-Hertig, Werner</creatorcontrib><creatorcontrib>Imboden, Dieter M</creatorcontrib><creatorcontrib>Baur, Heinrich</creatorcontrib><creatorcontrib>Graf, Thomas</creatorcontrib><creatorcontrib>Kipfer, Rolf</creatorcontrib><creatorcontrib>Swiss Federal Inst. of Tech., Dubendorf (SE)</creatorcontrib><title>A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples</title><title>Environmental science &amp; technology</title><addtitle>Environ. Sci. Technol</addtitle><description>The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes (3He, 4He, 20Ne, 21Ne, 22Ne, 36Ar, 40Ar, 84Kr, 136Xe) and tritium (3H) from water samples are described. The 3H concentration is measured indirectly by the 3He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3He/4He, 20Ne/22Ne, and 40Ar/36Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20Ne/22Ne and 36Ar/40Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.</description><subject>ARGON 36</subject><subject>ARGON 40</subject><subject>Environmental monitoring</subject><subject>ENVIRONMENTAL SCIENCES</subject><subject>Freshwater</subject><subject>Gases</subject><subject>HELIUM 3</subject><subject>HELIUM 4</subject><subject>Isotopes</subject><subject>KRYPTON 84</subject><subject>MASS SPECTROSCOPY</subject><subject>NEON 21</subject><subject>NEON 22</subject><subject>TRITIUM</subject><subject>WATER POLLUTION</subject><subject>XENON 136</subject><issn>0013-936X</issn><issn>1520-5851</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNpl0VFrFDEQB_BQFHpWH_wGQbHgw9pks7ndPB5HrdbaCne2xZcwzc5yqbubayYH3rc3ZaWCkoe8_GYy-Q9jr6X4IEUpT5CMEU0lNgdsJnUpCt1o-YzNhJCqMGp-e8heEN0LIUolmhn7seBfgYivtuhSDAOm6B1f7SnhwLsQedogX4zQ78kTDx2_DHc98jMgJA5jy9fRJ7_LNhfzG0gY-QqGbY_0kj3voCd89ec-Yt8_nq6Xn4qLq7PPy8VFAaqRqWhapSRWCsq2Ea0yGgB11c5rk4-CKo8p5B3I1oFy0sgOOgUNVqArDQZqdcTeTn0DJW_J-YRu48I45h_ZUuTyav6ojie1jeFhh5Ts4Mlh38OIYUdW1vNamFpm-OYfeB92MSdANkcmS6OUzuj9hFwMRBE7u41-gLi3UtjHRdinRWRbTNbnUH89QYg_bZ6r1nb9bWUv1fny_Lr-Ym-zfzd5cPT37f_7_gYuM5Rw</recordid><startdate>20000515</startdate><enddate>20000515</enddate><creator>Beyerle, Urs</creator><creator>Aeschbach-Hertig, Werner</creator><creator>Imboden, Dieter M</creator><creator>Baur, Heinrich</creator><creator>Graf, Thomas</creator><creator>Kipfer, Rolf</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7ST</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope><scope>SOI</scope><scope>7QH</scope><scope>7UA</scope><scope>F1W</scope><scope>H97</scope><scope>L.G</scope><scope>OTOTI</scope></search><sort><creationdate>20000515</creationdate><title>A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples</title><author>Beyerle, Urs ; Aeschbach-Hertig, Werner ; Imboden, Dieter M ; Baur, Heinrich ; Graf, Thomas ; Kipfer, Rolf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>ARGON 36</topic><topic>ARGON 40</topic><topic>Environmental monitoring</topic><topic>ENVIRONMENTAL SCIENCES</topic><topic>Freshwater</topic><topic>Gases</topic><topic>HELIUM 3</topic><topic>HELIUM 4</topic><topic>Isotopes</topic><topic>KRYPTON 84</topic><topic>MASS SPECTROSCOPY</topic><topic>NEON 21</topic><topic>NEON 22</topic><topic>TRITIUM</topic><topic>WATER POLLUTION</topic><topic>XENON 136</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Beyerle, Urs</creatorcontrib><creatorcontrib>Aeschbach-Hertig, Werner</creatorcontrib><creatorcontrib>Imboden, Dieter M</creatorcontrib><creatorcontrib>Baur, Heinrich</creatorcontrib><creatorcontrib>Graf, Thomas</creatorcontrib><creatorcontrib>Kipfer, Rolf</creatorcontrib><creatorcontrib>Swiss Federal Inst. of Tech., Dubendorf (SE)</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environment Abstracts</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) 3: Aquatic Pollution &amp; Environmental Quality</collection><collection>Aquatic Science &amp; Fisheries Abstracts (ASFA) Professional</collection><collection>OSTI.GOV</collection><jtitle>Environmental science &amp; technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Beyerle, Urs</au><au>Aeschbach-Hertig, Werner</au><au>Imboden, Dieter M</au><au>Baur, Heinrich</au><au>Graf, Thomas</au><au>Kipfer, Rolf</au><aucorp>Swiss Federal Inst. of Tech., Dubendorf (SE)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples</atitle><jtitle>Environmental science &amp; technology</jtitle><addtitle>Environ. Sci. Technol</addtitle><date>2000-05-15</date><risdate>2000</risdate><volume>34</volume><issue>10</issue><spage>2042</spage><epage>2050</epage><pages>2042-2050</pages><issn>0013-936X</issn><eissn>1520-5851</eissn><coden>ESTHAG</coden><abstract>The design, setup, and performance of a mass spectrometric system for the analysis of noble gas isotopes (3He, 4He, 20Ne, 21Ne, 22Ne, 36Ar, 40Ar, 84Kr, 136Xe) and tritium (3H) from water samples are described. The 3H concentration is measured indirectly by the 3He ingrowth from radioactive decay. After extraction, purification, and separation, the noble gases are measured in two noncommercial double-collector 90° magnetic sector mass spectrometers. We present a new approach for the analysis of the heavy noble gas isotopes that enables, in principle, simultaneous measurement of Ar, Kr, and Xe. Typical precisions of the measurements of 3H, He, Ne, Ar, Kr, and Xe concentrations are ±2.7%, ±0.3%, ±0.9%, ±0.3%, ±0.8%, and ±1.0%, respectively. For the isotopic ratios 3He/4He, 20Ne/22Ne, and 40Ar/36Ar the typical precisions are ±0.7%, ±0.3%, and ±0.2%. These values express the reproducibility of the measurement of an internal freshwater standard and include the overall stability of the system as well as of the extraction procedure. To verify the method, the noble gas concentrations of air-saturated water samples prepared under controlled conditions are compared with noble gas solubility data. The 20Ne/22Ne and 36Ar/40Ar fractionation during solution is estimated from 70 surface water samples to be −2.0 ± 0.2‰ and −1.3 ± 0.2‰, respectively.</abstract><cop>Easton</cop><pub>American Chemical Society</pub><doi>10.1021/es990840h</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0013-936X
ispartof Environmental science & technology, 2000-05, Vol.34 (10), p.2042-2050
issn 0013-936X
1520-5851
language eng
recordid cdi_osti_scitechconnect_20080467
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects ARGON 36
ARGON 40
Environmental monitoring
ENVIRONMENTAL SCIENCES
Freshwater
Gases
HELIUM 3
HELIUM 4
Isotopes
KRYPTON 84
MASS SPECTROSCOPY
NEON 21
NEON 22
TRITIUM
WATER POLLUTION
XENON 136
title A Mass Spectrometric System for the Analysis of Noble Gases and Tritium from Water Samples
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-16T22%3A05%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Mass%20Spectrometric%20System%20for%20the%20Analysis%20of%20Noble%20Gases%20and%20Tritium%20from%20Water%20Samples&rft.jtitle=Environmental%20science%20&%20technology&rft.au=Beyerle,%20Urs&rft.aucorp=Swiss%20Federal%20Inst.%20of%20Tech.,%20Dubendorf%20(SE)&rft.date=2000-05-15&rft.volume=34&rft.issue=10&rft.spage=2042&rft.epage=2050&rft.pages=2042-2050&rft.issn=0013-936X&rft.eissn=1520-5851&rft.coden=ESTHAG&rft_id=info:doi/10.1021/es990840h&rft_dat=%3Cproquest_osti_%3E54890929%3C/proquest_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a381t-8d331e43a2d80d395aae54d6797973a430801ba1dca3c191faf3a8e4a545a9a73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=230129335&rft_id=info:pmid/&rfr_iscdi=true