Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source

A 6 GHz, all-permanent magnet, 'volume-type' Electron Cyclotron Resonance (ECR) ion source has been initially tested at the Oak Ridge National Laboratory. The source has the following design properties: (1) an Al plasma chamber; (2) a mechanically adjustable, flat-bottomed mirror magnetic...

Full description

Saved in:
Bibliographic Details
Main Authors: Bilheux, H., Alton, G.D., Liu, Y., Meyer, F.W., Cole, J.M., Reed, C.A., Williams, C.L.
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 1
container_start_page
container_title
container_volume 680
creator Bilheux, H.
Alton, G.D.
Liu, Y.
Meyer, F.W.
Cole, J.M.
Reed, C.A.
Williams, C.L.
description A 6 GHz, all-permanent magnet, 'volume-type' Electron Cyclotron Resonance (ECR) ion source has been initially tested at the Oak Ridge National Laboratory. The source has the following design properties: (1) an Al plasma chamber; (2) a mechanically adjustable, flat-bottomed mirror magnetic field distribution tuned to the ECR condition; (3) a dodecapole cusp-magnet for radial plasma confinement; (4) a Right-Hand-Circularly-Polarized (RHCP) traveling wave RF injection system, (5) a movable three-electrode extraction system, and (6) facility for conversion into a conventional minimum-B magnetic field ''surface'' source configuration. Details of the source design, magnetic field distribution, operational parameters and initial results derived from first operation of the source (e.g., charge state spectra and intensity distributions for a given charge state) are provided for argon.
doi_str_mv 10.1063/1.1619890
format conference_proceeding
fullrecord <record><control><sourceid>osti</sourceid><recordid>TN_cdi_osti_scitechconnect_20632526</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20632526</sourcerecordid><originalsourceid>FETCH-LOGICAL-o183t-c6040fe2cf3dc7c3d919381bb3b3f834c2438a2b537916a829d7bf1da85d06883</originalsourceid><addsrcrecordid>eNotkM1LwzAcQIMoWKcH_4OAh12WmV_S5uM4yr5g4tAq3kaaJlulS2TNDvrXW9DTuz0eD6F7oFOggj_CFARopekFyqAogEgB4hJllOqcsJx_XKObvv-klGkpVYa269Cm1nS4cn1qwx5Hj9PBYYGXq58JnnUd2brT0QQXEn4y--DSBI_fY3c-OlJ9f7kxnpcvuI0Bv8bzybpbdOVN17u7f47Q22JelSuyeV6uy9mGRFA8EStoTr1j1vPGSssbDZorqGtec694bodWZVhdcKlBGMV0I2sPjVFFQ4VSfIQe_rxx6N71tk3OHmwMwdm0Y8MKVjDBfwEqFUz7</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Bilheux, H. ; Alton, G.D. ; Liu, Y. ; Meyer, F.W. ; Cole, J.M. ; Reed, C.A. ; Williams, C.L.</creator><creatorcontrib>Bilheux, H. ; Alton, G.D. ; Liu, Y. ; Meyer, F.W. ; Cole, J.M. ; Reed, C.A. ; Williams, C.L.</creatorcontrib><description>A 6 GHz, all-permanent magnet, 'volume-type' Electron Cyclotron Resonance (ECR) ion source has been initially tested at the Oak Ridge National Laboratory. The source has the following design properties: (1) an Al plasma chamber; (2) a mechanically adjustable, flat-bottomed mirror magnetic field distribution tuned to the ECR condition; (3) a dodecapole cusp-magnet for radial plasma confinement; (4) a Right-Hand-Circularly-Polarized (RHCP) traveling wave RF injection system, (5) a movable three-electrode extraction system, and (6) facility for conversion into a conventional minimum-B magnetic field ''surface'' source configuration. Details of the source design, magnetic field distribution, operational parameters and initial results derived from first operation of the source (e.g., charge state spectra and intensity distributions for a given charge state) are provided for argon.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.1619890</identifier><language>eng</language><publisher>United States</publisher><subject>ARGON ; BEAM INJECTION ; CHARGE STATES ; CUSPED GEOMETRIES ; ECR ION SOURCES ; GHZ RANGE 01-100 ; MAGNETIC FIELDS ; PARTICLE ACCELERATORS ; PERMANENT MAGNETS ; PLASMA ; PLASMA CONFINEMENT ; RF SYSTEMS ; SPATIAL DISTRIBUTION ; TRAVELLING WAVES</subject><ispartof>AIP conference proceedings, 2003, Vol.680 (1)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/20632526$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Bilheux, H.</creatorcontrib><creatorcontrib>Alton, G.D.</creatorcontrib><creatorcontrib>Liu, Y.</creatorcontrib><creatorcontrib>Meyer, F.W.</creatorcontrib><creatorcontrib>Cole, J.M.</creatorcontrib><creatorcontrib>Reed, C.A.</creatorcontrib><creatorcontrib>Williams, C.L.</creatorcontrib><title>Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source</title><title>AIP conference proceedings</title><description>A 6 GHz, all-permanent magnet, 'volume-type' Electron Cyclotron Resonance (ECR) ion source has been initially tested at the Oak Ridge National Laboratory. The source has the following design properties: (1) an Al plasma chamber; (2) a mechanically adjustable, flat-bottomed mirror magnetic field distribution tuned to the ECR condition; (3) a dodecapole cusp-magnet for radial plasma confinement; (4) a Right-Hand-Circularly-Polarized (RHCP) traveling wave RF injection system, (5) a movable three-electrode extraction system, and (6) facility for conversion into a conventional minimum-B magnetic field ''surface'' source configuration. Details of the source design, magnetic field distribution, operational parameters and initial results derived from first operation of the source (e.g., charge state spectra and intensity distributions for a given charge state) are provided for argon.</description><subject>ARGON</subject><subject>BEAM INJECTION</subject><subject>CHARGE STATES</subject><subject>CUSPED GEOMETRIES</subject><subject>ECR ION SOURCES</subject><subject>GHZ RANGE 01-100</subject><subject>MAGNETIC FIELDS</subject><subject>PARTICLE ACCELERATORS</subject><subject>PERMANENT MAGNETS</subject><subject>PLASMA</subject><subject>PLASMA CONFINEMENT</subject><subject>RF SYSTEMS</subject><subject>SPATIAL DISTRIBUTION</subject><subject>TRAVELLING WAVES</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2003</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkM1LwzAcQIMoWKcH_4OAh12WmV_S5uM4yr5g4tAq3kaaJlulS2TNDvrXW9DTuz0eD6F7oFOggj_CFARopekFyqAogEgB4hJllOqcsJx_XKObvv-klGkpVYa269Cm1nS4cn1qwx5Hj9PBYYGXq58JnnUd2brT0QQXEn4y--DSBI_fY3c-OlJ9f7kxnpcvuI0Bv8bzybpbdOVN17u7f47Q22JelSuyeV6uy9mGRFA8EStoTr1j1vPGSssbDZorqGtec694bodWZVhdcKlBGMV0I2sPjVFFQ4VSfIQe_rxx6N71tk3OHmwMwdm0Y8MKVjDBfwEqFUz7</recordid><startdate>20030826</startdate><enddate>20030826</enddate><creator>Bilheux, H.</creator><creator>Alton, G.D.</creator><creator>Liu, Y.</creator><creator>Meyer, F.W.</creator><creator>Cole, J.M.</creator><creator>Reed, C.A.</creator><creator>Williams, C.L.</creator><scope>OTOTI</scope></search><sort><creationdate>20030826</creationdate><title>Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source</title><author>Bilheux, H. ; Alton, G.D. ; Liu, Y. ; Meyer, F.W. ; Cole, J.M. ; Reed, C.A. ; Williams, C.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o183t-c6040fe2cf3dc7c3d919381bb3b3f834c2438a2b537916a829d7bf1da85d06883</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2003</creationdate><topic>ARGON</topic><topic>BEAM INJECTION</topic><topic>CHARGE STATES</topic><topic>CUSPED GEOMETRIES</topic><topic>ECR ION SOURCES</topic><topic>GHZ RANGE 01-100</topic><topic>MAGNETIC FIELDS</topic><topic>PARTICLE ACCELERATORS</topic><topic>PERMANENT MAGNETS</topic><topic>PLASMA</topic><topic>PLASMA CONFINEMENT</topic><topic>RF SYSTEMS</topic><topic>SPATIAL DISTRIBUTION</topic><topic>TRAVELLING WAVES</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bilheux, H.</creatorcontrib><creatorcontrib>Alton, G.D.</creatorcontrib><creatorcontrib>Liu, Y.</creatorcontrib><creatorcontrib>Meyer, F.W.</creatorcontrib><creatorcontrib>Cole, J.M.</creatorcontrib><creatorcontrib>Reed, C.A.</creatorcontrib><creatorcontrib>Williams, C.L.</creatorcontrib><collection>OSTI.GOV</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bilheux, H.</au><au>Alton, G.D.</au><au>Liu, Y.</au><au>Meyer, F.W.</au><au>Cole, J.M.</au><au>Reed, C.A.</au><au>Williams, C.L.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source</atitle><btitle>AIP conference proceedings</btitle><date>2003-08-26</date><risdate>2003</risdate><volume>680</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><abstract>A 6 GHz, all-permanent magnet, 'volume-type' Electron Cyclotron Resonance (ECR) ion source has been initially tested at the Oak Ridge National Laboratory. The source has the following design properties: (1) an Al plasma chamber; (2) a mechanically adjustable, flat-bottomed mirror magnetic field distribution tuned to the ECR condition; (3) a dodecapole cusp-magnet for radial plasma confinement; (4) a Right-Hand-Circularly-Polarized (RHCP) traveling wave RF injection system, (5) a movable three-electrode extraction system, and (6) facility for conversion into a conventional minimum-B magnetic field ''surface'' source configuration. Details of the source design, magnetic field distribution, operational parameters and initial results derived from first operation of the source (e.g., charge state spectra and intensity distributions for a given charge state) are provided for argon.</abstract><cop>United States</cop><doi>10.1063/1.1619890</doi></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2003, Vol.680 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_osti_scitechconnect_20632526
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects ARGON
BEAM INJECTION
CHARGE STATES
CUSPED GEOMETRIES
ECR ION SOURCES
GHZ RANGE 01-100
MAGNETIC FIELDS
PARTICLE ACCELERATORS
PERMANENT MAGNETS
PLASMA
PLASMA CONFINEMENT
RF SYSTEMS
SPATIAL DISTRIBUTION
TRAVELLING WAVES
title Initial Testing of the 6 GHz, All-Permanent Magnet, 'Volume-Type' ECR ion Source
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T03%3A18%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-osti&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Initial%20Testing%20of%20the%206%20GHz,%20All-Permanent%20Magnet,%20'Volume-Type'%20ECR%20ion%20Source&rft.btitle=AIP%20conference%20proceedings&rft.au=Bilheux,%20H.&rft.date=2003-08-26&rft.volume=680&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft_id=info:doi/10.1063/1.1619890&rft_dat=%3Costi%3E20632526%3C/osti%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-o183t-c6040fe2cf3dc7c3d919381bb3b3f834c2438a2b537916a829d7bf1da85d06883%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true