Loading…
Two-dimensional phase contrast interferometer for fluctuations study on LHD
C O 2 laser based phase contrast interferometer was used previously on LHD to study plasma density microfluctuations. New two-dimensional 6×8 elements array of CdHgTe photoconductors was employed for detection. In addition to commonly measured intensity, frequency spectrum, and two-point correlation...
Saved in:
Published in: | Review of Scientific Instruments 2004-10, Vol.75 (10), p.3439-3441 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | C
O
2
laser based phase contrast interferometer was used previously on LHD to study plasma density microfluctuations. New two-dimensional
6×8
elements array of CdHgTe photoconductors was employed for detection. In addition to commonly measured intensity, frequency spectrum, and two-point correlation two-dimensional detector array allows determining the direction of propagation of waves in plasma. From the angular distribution it is possible to obtain localized along the viewing line properties of fluctuations using strong magnetic shear in LHD. As a result, the radial profiles of density microfluctuations can be obtained with
1 μ
s
temporal resolution determined by detector bandwidth. The described scheme was tested using ultrasonic wave in air. New imaging diagnostics has been installed on LHD and first experimental results are reported. |
---|---|
ISSN: | 0034-6748 1089-7623 |
DOI: | 10.1063/1.1784528 |