Loading…

Effect of Te precipitates on the performance of CdZnTe detectors

Measurements using the National Synchrotron Light Source provided a detailed comparisons of the microscale detector response and infrared microscopy images for CdZnTe Frisch-ring x-ray and gamma detectors. Analysis of the data showed conclusively that local deteriorations of the electron charge coll...

Full description

Saved in:
Bibliographic Details
Published in:Applied physics letters 2006-04, Vol.88 (14), p.143515-143515-3
Main Authors: Carini, G. A., Bolotnikov, A. E., Camarda, G. S., Wright, G. W., James, R. B., Li, L.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Measurements using the National Synchrotron Light Source provided a detailed comparisons of the microscale detector response and infrared microscopy images for CdZnTe Frisch-ring x-ray and gamma detectors. Analysis of the data showed conclusively that local deteriorations of the electron charge collection and x-ray device response fully correlate with the presence of Te precipitates as seen in the IR images. Effects of the surface processing conditions on the detector performance were also clearly observed.
ISSN:0003-6951
1077-3118
DOI:10.1063/1.2189912