Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I

The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her th...

Full description

Saved in:
Bibliographic Details
Published in:AIP conference proceedings 2006-09, Vol.854 (1)
Main Authors: Vega-Carrillo, Hector Rene, Manzanares-Acuna, Eduardo, Hernandez-Davila, Victor Martin, Arcos-Pichardo, Areli, Barquero, Raquel, Iniguez, M. Pilar
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 1
container_start_page
container_title AIP conference proceedings
container_volume 854
creator Vega-Carrillo, Hector Rene
Manzanares-Acuna, Eduardo
Hernandez-Davila, Victor Martin
Arcos-Pichardo, Areli
Barquero, Raquel
Iniguez, M. Pilar
description The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.
doi_str_mv 10.1063/1.2356404
format article
fullrecord <record><control><sourceid>osti</sourceid><recordid>TN_cdi_osti_scitechconnect_20888214</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>20888214</sourcerecordid><originalsourceid>FETCH-osti_scitechconnect_208882143</originalsourceid><addsrcrecordid>eNqNyrsKwjAUANAgCtbH4B9ccK7mJunDUaxSB8GhopvUerUVTaA3_X8XP8DpLEeIGcoFylgvcaF0FBtpeiLAKMIwiTHui0DKlQmV0ZehGDG_pFSrJEkDka9v7Nob3SFzTNBY8DXByVPbMbgHlFDULREcnPU1w7Glpy2th7P7lBayjsA7QI37iRg8yjfT9OdYzHfbYpOHjn1z5arxVNWVs5Yqf1UyTVOFRv-3vjSyPwg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Vega-Carrillo, Hector Rene ; Manzanares-Acuna, Eduardo ; Hernandez-Davila, Victor Martin ; Arcos-Pichardo, Areli ; Barquero, Raquel ; Iniguez, M. Pilar</creator><creatorcontrib>Vega-Carrillo, Hector Rene ; Manzanares-Acuna, Eduardo ; Hernandez-Davila, Victor Martin ; Arcos-Pichardo, Areli ; Barquero, Raquel ; Iniguez, M. Pilar</creatorcontrib><description>The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.2356404</identifier><language>eng</language><publisher>United States</publisher><subject>ATTENUATION ; DIAGNOSIS ; DOSIMETRY ; FETUSES ; GYNECOLOGY ; IODINE 131 ; MONTE CARLO METHOD ; NECK ; PATIENTS ; PHANTOMS ; PHOTONS ; RADIATION DOSES ; RADIOLOGY AND NUCLEAR MEDICINE ; THYROID ; UTERUS ; WOMEN</subject><ispartof>AIP conference proceedings, 2006-09, Vol.854 (1)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/20888214$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Vega-Carrillo, Hector Rene</creatorcontrib><creatorcontrib>Manzanares-Acuna, Eduardo</creatorcontrib><creatorcontrib>Hernandez-Davila, Victor Martin</creatorcontrib><creatorcontrib>Arcos-Pichardo, Areli</creatorcontrib><creatorcontrib>Barquero, Raquel</creatorcontrib><creatorcontrib>Iniguez, M. Pilar</creatorcontrib><title>Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I</title><title>AIP conference proceedings</title><description>The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.</description><subject>ATTENUATION</subject><subject>DIAGNOSIS</subject><subject>DOSIMETRY</subject><subject>FETUSES</subject><subject>GYNECOLOGY</subject><subject>IODINE 131</subject><subject>MONTE CARLO METHOD</subject><subject>NECK</subject><subject>PATIENTS</subject><subject>PHANTOMS</subject><subject>PHOTONS</subject><subject>RADIATION DOSES</subject><subject>RADIOLOGY AND NUCLEAR MEDICINE</subject><subject>THYROID</subject><subject>UTERUS</subject><subject>WOMEN</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqNyrsKwjAUANAgCtbH4B9ccK7mJunDUaxSB8GhopvUerUVTaA3_X8XP8DpLEeIGcoFylgvcaF0FBtpeiLAKMIwiTHui0DKlQmV0ZehGDG_pFSrJEkDka9v7Nob3SFzTNBY8DXByVPbMbgHlFDULREcnPU1w7Glpy2th7P7lBayjsA7QI37iRg8yjfT9OdYzHfbYpOHjn1z5arxVNWVs5Yqf1UyTVOFRv-3vjSyPwg</recordid><startdate>20060908</startdate><enddate>20060908</enddate><creator>Vega-Carrillo, Hector Rene</creator><creator>Manzanares-Acuna, Eduardo</creator><creator>Hernandez-Davila, Victor Martin</creator><creator>Arcos-Pichardo, Areli</creator><creator>Barquero, Raquel</creator><creator>Iniguez, M. Pilar</creator><scope>OTOTI</scope></search><sort><creationdate>20060908</creationdate><title>Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I</title><author>Vega-Carrillo, Hector Rene ; Manzanares-Acuna, Eduardo ; Hernandez-Davila, Victor Martin ; Arcos-Pichardo, Areli ; Barquero, Raquel ; Iniguez, M. Pilar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-osti_scitechconnect_208882143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>ATTENUATION</topic><topic>DIAGNOSIS</topic><topic>DOSIMETRY</topic><topic>FETUSES</topic><topic>GYNECOLOGY</topic><topic>IODINE 131</topic><topic>MONTE CARLO METHOD</topic><topic>NECK</topic><topic>PATIENTS</topic><topic>PHANTOMS</topic><topic>PHOTONS</topic><topic>RADIATION DOSES</topic><topic>RADIOLOGY AND NUCLEAR MEDICINE</topic><topic>THYROID</topic><topic>UTERUS</topic><topic>WOMEN</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vega-Carrillo, Hector Rene</creatorcontrib><creatorcontrib>Manzanares-Acuna, Eduardo</creatorcontrib><creatorcontrib>Hernandez-Davila, Victor Martin</creatorcontrib><creatorcontrib>Arcos-Pichardo, Areli</creatorcontrib><creatorcontrib>Barquero, Raquel</creatorcontrib><creatorcontrib>Iniguez, M. Pilar</creatorcontrib><collection>OSTI.GOV</collection><jtitle>AIP conference proceedings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vega-Carrillo, Hector Rene</au><au>Manzanares-Acuna, Eduardo</au><au>Hernandez-Davila, Victor Martin</au><au>Arcos-Pichardo, Areli</au><au>Barquero, Raquel</au><au>Iniguez, M. Pilar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I</atitle><jtitle>AIP conference proceedings</jtitle><date>2006-09-08</date><risdate>2006</risdate><volume>854</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><abstract>The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.</abstract><cop>United States</cop><doi>10.1063/1.2356404</doi></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2006-09, Vol.854 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_osti_scitechconnect_20888214
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects ATTENUATION
DIAGNOSIS
DOSIMETRY
FETUSES
GYNECOLOGY
IODINE 131
MONTE CARLO METHOD
NECK
PATIENTS
PHANTOMS
PHOTONS
RADIATION DOSES
RADIOLOGY AND NUCLEAR MEDICINE
THYROID
UTERUS
WOMEN
title Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T02%3A09%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-osti&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Absorbed%20Dose%20in%20the%20Uterus%20of%20a%20Three%20Months%20Pregnant%20Woman%20Due%20to%20131I&rft.jtitle=AIP%20conference%20proceedings&rft.au=Vega-Carrillo,%20Hector%20Rene&rft.date=2006-09-08&rft.volume=854&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft_id=info:doi/10.1063/1.2356404&rft_dat=%3Costi%3E20888214%3C/osti%3E%3Cgrp_id%3Ecdi_FETCH-osti_scitechconnect_208882143%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true