Loading…
Implementation of a Lateral TBI protocol in a Mexican Cancer Center
The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validate...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 97 |
container_issue | 1 |
container_start_page | 93 |
container_title | |
container_volume | 1032 |
creator | Mesa, Francisco Esquivel, Carlos Eng, Tony Papanikolaou, Niko Sosa, Modesto A |
description | The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5 % respect of the prescribed dose. |
doi_str_mv | 10.1063/1.2979311 |
format | conference_proceeding |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_21149300</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33803429</sourcerecordid><originalsourceid>FETCH-LOGICAL-o214t-3bddcc0def221dc75fdbbeb6e659908a933d48e1b38c3f4e9a3ce4b1574ad1823</originalsourceid><addsrcrecordid>eNotjktLxDAUhYMPcBxn4T8ICO465uYmTbPU4mNgxM0I7kqa3mKlk4xNBH--hXF1Fuf7DoexaxBrECXewVpaYxHghC1AayhMCeUpW1lTCYNaCa1LOGMLIawqpMKPC3aZ0pcQs2aqBas3-8NIewrZ5SEGHnvu-NZlmtzIdw8bfphijj6OfAhz80q_g3eB1y54mng9ezRdsfPejYlW_7lk70-Pu_ql2L49b-r7bRElqFxg23Xei456KaHzRvdd21JbUqmtFZWziJ2qCFqsPPaKrENPqgVtlOugkrhkN8fdmPLQJD9k8p8-hkA-NxJAWRRipm6P1Pz8-4dSbvZD8jSOLlD8SQ1iJVBJi3-dj1sL</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>33803429</pqid></control><display><type>conference_proceeding</type><title>Implementation of a Lateral TBI protocol in a Mexican Cancer Center</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Mesa, Francisco ; Esquivel, Carlos ; Eng, Tony ; Papanikolaou, Niko ; Sosa, Modesto A</creator><creatorcontrib>Mesa, Francisco ; Esquivel, Carlos ; Eng, Tony ; Papanikolaou, Niko ; Sosa, Modesto A</creatorcontrib><description>The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5 % respect of the prescribed dose.</description><identifier>ISSN: 0094-243X</identifier><identifier>ISBN: 9780735405561</identifier><identifier>ISBN: 0735405565</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/1.2979311</identifier><language>eng</language><publisher>United States</publisher><subject>BIOLOGICAL RADIATION EFFECTS ; BONE MARROW ; DOSES ; IN VIVO ; LUNGS ; LYMPHOMAS ; MEXICO ; PATIENTS ; PHOTON BEAMS ; RADIOLOGY AND NUCLEAR MEDICINE ; RADIOTHERAPY ; THERMOLUMINESCENT DOSIMETRY ; TRANSPLANTS ; WHOLE-BODY IRRADIATION</subject><ispartof>AIP conference proceedings, 2008, Vol.1032 (1), p.93-97</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27922,27923</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/21149300$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Mesa, Francisco</creatorcontrib><creatorcontrib>Esquivel, Carlos</creatorcontrib><creatorcontrib>Eng, Tony</creatorcontrib><creatorcontrib>Papanikolaou, Niko</creatorcontrib><creatorcontrib>Sosa, Modesto A</creatorcontrib><title>Implementation of a Lateral TBI protocol in a Mexican Cancer Center</title><title>AIP conference proceedings</title><description>The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5 % respect of the prescribed dose.</description><subject>BIOLOGICAL RADIATION EFFECTS</subject><subject>BONE MARROW</subject><subject>DOSES</subject><subject>IN VIVO</subject><subject>LUNGS</subject><subject>LYMPHOMAS</subject><subject>MEXICO</subject><subject>PATIENTS</subject><subject>PHOTON BEAMS</subject><subject>RADIOLOGY AND NUCLEAR MEDICINE</subject><subject>RADIOTHERAPY</subject><subject>THERMOLUMINESCENT DOSIMETRY</subject><subject>TRANSPLANTS</subject><subject>WHOLE-BODY IRRADIATION</subject><issn>0094-243X</issn><issn>1551-7616</issn><isbn>9780735405561</isbn><isbn>0735405565</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2008</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotjktLxDAUhYMPcBxn4T8ICO465uYmTbPU4mNgxM0I7kqa3mKlk4xNBH--hXF1Fuf7DoexaxBrECXewVpaYxHghC1AayhMCeUpW1lTCYNaCa1LOGMLIawqpMKPC3aZ0pcQs2aqBas3-8NIewrZ5SEGHnvu-NZlmtzIdw8bfphijj6OfAhz80q_g3eB1y54mng9ezRdsfPejYlW_7lk70-Pu_ql2L49b-r7bRElqFxg23Xei456KaHzRvdd21JbUqmtFZWziJ2qCFqsPPaKrENPqgVtlOugkrhkN8fdmPLQJD9k8p8-hkA-NxJAWRRipm6P1Pz8-4dSbvZD8jSOLlD8SQ1iJVBJi3-dj1sL</recordid><startdate>20080101</startdate><enddate>20080101</enddate><creator>Mesa, Francisco</creator><creator>Esquivel, Carlos</creator><creator>Eng, Tony</creator><creator>Papanikolaou, Niko</creator><creator>Sosa, Modesto A</creator><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20080101</creationdate><title>Implementation of a Lateral TBI protocol in a Mexican Cancer Center</title><author>Mesa, Francisco ; Esquivel, Carlos ; Eng, Tony ; Papanikolaou, Niko ; Sosa, Modesto A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-o214t-3bddcc0def221dc75fdbbeb6e659908a933d48e1b38c3f4e9a3ce4b1574ad1823</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2008</creationdate><topic>BIOLOGICAL RADIATION EFFECTS</topic><topic>BONE MARROW</topic><topic>DOSES</topic><topic>IN VIVO</topic><topic>LUNGS</topic><topic>LYMPHOMAS</topic><topic>MEXICO</topic><topic>PATIENTS</topic><topic>PHOTON BEAMS</topic><topic>RADIOLOGY AND NUCLEAR MEDICINE</topic><topic>RADIOTHERAPY</topic><topic>THERMOLUMINESCENT DOSIMETRY</topic><topic>TRANSPLANTS</topic><topic>WHOLE-BODY IRRADIATION</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mesa, Francisco</creatorcontrib><creatorcontrib>Esquivel, Carlos</creatorcontrib><creatorcontrib>Eng, Tony</creatorcontrib><creatorcontrib>Papanikolaou, Niko</creatorcontrib><creatorcontrib>Sosa, Modesto A</creatorcontrib><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mesa, Francisco</au><au>Esquivel, Carlos</au><au>Eng, Tony</au><au>Papanikolaou, Niko</au><au>Sosa, Modesto A</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Implementation of a Lateral TBI protocol in a Mexican Cancer Center</atitle><btitle>AIP conference proceedings</btitle><date>2008-01-01</date><risdate>2008</risdate><volume>1032</volume><issue>1</issue><spage>93</spage><epage>97</epage><pages>93-97</pages><issn>0094-243X</issn><eissn>1551-7616</eissn><isbn>9780735405561</isbn><isbn>0735405565</isbn><abstract>The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5 % respect of the prescribed dose.</abstract><cop>United States</cop><doi>10.1063/1.2979311</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2008, Vol.1032 (1), p.93-97 |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_osti_scitechconnect_21149300 |
source | American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list) |
subjects | BIOLOGICAL RADIATION EFFECTS BONE MARROW DOSES IN VIVO LUNGS LYMPHOMAS MEXICO PATIENTS PHOTON BEAMS RADIOLOGY AND NUCLEAR MEDICINE RADIOTHERAPY THERMOLUMINESCENT DOSIMETRY TRANSPLANTS WHOLE-BODY IRRADIATION |
title | Implementation of a Lateral TBI protocol in a Mexican Cancer Center |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T10%3A26%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Implementation%20of%20a%20Lateral%20TBI%20protocol%20in%20a%20Mexican%20Cancer%20Center&rft.btitle=AIP%20conference%20proceedings&rft.au=Mesa,%20Francisco&rft.date=2008-01-01&rft.volume=1032&rft.issue=1&rft.spage=93&rft.epage=97&rft.pages=93-97&rft.issn=0094-243X&rft.eissn=1551-7616&rft.isbn=9780735405561&rft.isbn_list=0735405565&rft_id=info:doi/10.1063/1.2979311&rft_dat=%3Cproquest_osti_%3E33803429%3C/proquest_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-o214t-3bddcc0def221dc75fdbbeb6e659908a933d48e1b38c3f4e9a3ce4b1574ad1823%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=33803429&rft_id=info:pmid/&rfr_iscdi=true |