Loading…

Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend

Questions related to the determination of the flow rate of coolant in the pipelines of electric plants are considered. Amethod of determining the flow of single-phase coolant for the case of an asymmetric unstabilized velocity profile that is present following a bend in a pipeline is proposed. Resul...

Full description

Saved in:
Bibliographic Details
Published in:Power technology and engineering 2018, Vol.51 (5), p.562-567
Main Authors: Boltenko, É. A., Davydov, M. V., Korol’kov, B. M., Basov, A. V., Kononenko, I. V., Sharov, V. P.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 567
container_issue 5
container_start_page 562
container_title Power technology and engineering
container_volume 51
creator Boltenko, É. A.
Davydov, M. V.
Korol’kov, B. M.
Basov, A. V.
Kononenko, I. V.
Sharov, V. P.
description Questions related to the determination of the flow rate of coolant in the pipelines of electric plants are considered. Amethod of determining the flow of single-phase coolant for the case of an asymmetric unstabilized velocity profile that is present following a bend in a pipeline is proposed. Results from the use of the proposed method in novel experiments on the testing unit of the Élektrogorsk Scientific Research Center and in the steam pipelines of power unit No. 3 of the Balakovo nuclear power plant are presented.
doi_str_mv 10.1007/s10749-018-0874-8
format article
fullrecord <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_22756173</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2006847514</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2698-d857d24f35db1b4a6b6f1f4af445ccf4398cc40e311da399a7565af3954aaf203</originalsourceid><addsrcrecordid>eNp1kUFLwzAYhoMoOKc_wFvAczVJkzY9zmlVEBRx4C2kabJldMlMMob-elsq7uTpC1-e9-WDB4BLjK4xQuVNxKikVYYwzxAvacaPwASzEmWYFvz4780-TsFZjGuECCI0n4B4p5MOG-tkst5Bb2BaaVh3fg_fZNLDYu59J12C1sFXu9WddTrCvU0ruHAxycZ29lu3Y6bH625n2wEeimZBS1j7rv-zbgklvNWuPQcnRnZRX_zOKVjU9-_zx-z55eFpPnvOFCkqnrWclS2hJmdtgxsqi6Yw2FBpKGVKGZpXXCmKdI5xK_OqkiUrmDR5xaiUhqB8Cq7GXh-TFVHZpNVKeee0SoKQHsdlfqC2wX_udExi7XfB9YcJglDBackw7Sk8Uir4GIM2YhvsRoYvgZEYDIjRgOgNiMGA4H2GjJnYs26pw6H5_9APPduH9g</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2006847514</pqid></control><display><type>article</type><title>Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend</title><source>Springer Link</source><creator>Boltenko, É. A. ; Davydov, M. V. ; Korol’kov, B. M. ; Basov, A. V. ; Kononenko, I. V. ; Sharov, V. P.</creator><creatorcontrib>Boltenko, É. A. ; Davydov, M. V. ; Korol’kov, B. M. ; Basov, A. V. ; Kononenko, I. V. ; Sharov, V. P.</creatorcontrib><description>Questions related to the determination of the flow rate of coolant in the pipelines of electric plants are considered. Amethod of determining the flow of single-phase coolant for the case of an asymmetric unstabilized velocity profile that is present following a bend in a pipeline is proposed. Results from the use of the proposed method in novel experiments on the testing unit of the Élektrogorsk Scientific Research Center and in the steam pipelines of power unit No. 3 of the Balakovo nuclear power plant are presented.</description><identifier>ISSN: 1570-145X</identifier><identifier>EISSN: 1570-1468</identifier><identifier>DOI: 10.1007/s10749-018-0874-8</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>ASYMMETRY ; BALAKOVO-3 REACTOR ; COOLANTS ; Electrical Machines and Networks ; Energy ; Energy Systems ; ENGINEERING ; FLOW RATE ; Flow velocity ; Foundations ; Geoengineering ; Hydraulics ; Nuclear power plants ; PIPELINES ; Power Electronics ; REACTOR COOLING SYSTEMS ; Renewable and Green Energy ; Steam electric power generation ; Velocity distribution</subject><ispartof>Power technology and engineering, 2018, Vol.51 (5), p.562-567</ispartof><rights>Springer Science+Business Media, LLC, part of Springer Nature 2018</rights><rights>Copyright Springer Science &amp; Business Media 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/22756173$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Boltenko, É. A.</creatorcontrib><creatorcontrib>Davydov, M. V.</creatorcontrib><creatorcontrib>Korol’kov, B. M.</creatorcontrib><creatorcontrib>Basov, A. V.</creatorcontrib><creatorcontrib>Kononenko, I. V.</creatorcontrib><creatorcontrib>Sharov, V. P.</creatorcontrib><title>Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend</title><title>Power technology and engineering</title><addtitle>Power Technol Eng</addtitle><description>Questions related to the determination of the flow rate of coolant in the pipelines of electric plants are considered. Amethod of determining the flow of single-phase coolant for the case of an asymmetric unstabilized velocity profile that is present following a bend in a pipeline is proposed. Results from the use of the proposed method in novel experiments on the testing unit of the Élektrogorsk Scientific Research Center and in the steam pipelines of power unit No. 3 of the Balakovo nuclear power plant are presented.</description><subject>ASYMMETRY</subject><subject>BALAKOVO-3 REACTOR</subject><subject>COOLANTS</subject><subject>Electrical Machines and Networks</subject><subject>Energy</subject><subject>Energy Systems</subject><subject>ENGINEERING</subject><subject>FLOW RATE</subject><subject>Flow velocity</subject><subject>Foundations</subject><subject>Geoengineering</subject><subject>Hydraulics</subject><subject>Nuclear power plants</subject><subject>PIPELINES</subject><subject>Power Electronics</subject><subject>REACTOR COOLING SYSTEMS</subject><subject>Renewable and Green Energy</subject><subject>Steam electric power generation</subject><subject>Velocity distribution</subject><issn>1570-145X</issn><issn>1570-1468</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kUFLwzAYhoMoOKc_wFvAczVJkzY9zmlVEBRx4C2kabJldMlMMob-elsq7uTpC1-e9-WDB4BLjK4xQuVNxKikVYYwzxAvacaPwASzEmWYFvz4780-TsFZjGuECCI0n4B4p5MOG-tkst5Bb2BaaVh3fg_fZNLDYu59J12C1sFXu9WddTrCvU0ruHAxycZ29lu3Y6bH625n2wEeimZBS1j7rv-zbgklvNWuPQcnRnZRX_zOKVjU9-_zx-z55eFpPnvOFCkqnrWclS2hJmdtgxsqi6Yw2FBpKGVKGZpXXCmKdI5xK_OqkiUrmDR5xaiUhqB8Cq7GXh-TFVHZpNVKeee0SoKQHsdlfqC2wX_udExi7XfB9YcJglDBackw7Sk8Uir4GIM2YhvsRoYvgZEYDIjRgOgNiMGA4H2GjJnYs26pw6H5_9APPduH9g</recordid><startdate>2018</startdate><enddate>2018</enddate><creator>Boltenko, É. A.</creator><creator>Davydov, M. V.</creator><creator>Korol’kov, B. M.</creator><creator>Basov, A. V.</creator><creator>Kononenko, I. V.</creator><creator>Sharov, V. P.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>2018</creationdate><title>Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend</title><author>Boltenko, É. A. ; Davydov, M. V. ; Korol’kov, B. M. ; Basov, A. V. ; Kononenko, I. V. ; Sharov, V. P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2698-d857d24f35db1b4a6b6f1f4af445ccf4398cc40e311da399a7565af3954aaf203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>ASYMMETRY</topic><topic>BALAKOVO-3 REACTOR</topic><topic>COOLANTS</topic><topic>Electrical Machines and Networks</topic><topic>Energy</topic><topic>Energy Systems</topic><topic>ENGINEERING</topic><topic>FLOW RATE</topic><topic>Flow velocity</topic><topic>Foundations</topic><topic>Geoengineering</topic><topic>Hydraulics</topic><topic>Nuclear power plants</topic><topic>PIPELINES</topic><topic>Power Electronics</topic><topic>REACTOR COOLING SYSTEMS</topic><topic>Renewable and Green Energy</topic><topic>Steam electric power generation</topic><topic>Velocity distribution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boltenko, É. A.</creatorcontrib><creatorcontrib>Davydov, M. V.</creatorcontrib><creatorcontrib>Korol’kov, B. M.</creatorcontrib><creatorcontrib>Basov, A. V.</creatorcontrib><creatorcontrib>Kononenko, I. V.</creatorcontrib><creatorcontrib>Sharov, V. P.</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Power technology and engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boltenko, É. A.</au><au>Davydov, M. V.</au><au>Korol’kov, B. M.</au><au>Basov, A. V.</au><au>Kononenko, I. V.</au><au>Sharov, V. P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend</atitle><jtitle>Power technology and engineering</jtitle><stitle>Power Technol Eng</stitle><date>2018</date><risdate>2018</risdate><volume>51</volume><issue>5</issue><spage>562</spage><epage>567</epage><pages>562-567</pages><issn>1570-145X</issn><eissn>1570-1468</eissn><abstract>Questions related to the determination of the flow rate of coolant in the pipelines of electric plants are considered. Amethod of determining the flow of single-phase coolant for the case of an asymmetric unstabilized velocity profile that is present following a bend in a pipeline is proposed. Results from the use of the proposed method in novel experiments on the testing unit of the Élektrogorsk Scientific Research Center and in the steam pipelines of power unit No. 3 of the Balakovo nuclear power plant are presented.</abstract><cop>New York</cop><pub>Springer US</pub><doi>10.1007/s10749-018-0874-8</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1570-145X
ispartof Power technology and engineering, 2018, Vol.51 (5), p.562-567
issn 1570-145X
1570-1468
language eng
recordid cdi_osti_scitechconnect_22756173
source Springer Link
subjects ASYMMETRY
BALAKOVO-3 REACTOR
COOLANTS
Electrical Machines and Networks
Energy
Energy Systems
ENGINEERING
FLOW RATE
Flow velocity
Foundations
Geoengineering
Hydraulics
Nuclear power plants
PIPELINES
Power Electronics
REACTOR COOLING SYSTEMS
Renewable and Green Energy
Steam electric power generation
Velocity distribution
title Determination of the Flow Rate of Coolant in Pipelines with Unstabilized Flow of Fluid in the Area Following a Bend
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T05%3A43%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20the%20Flow%20Rate%20of%20Coolant%20in%20Pipelines%20with%20Unstabilized%20Flow%20of%20Fluid%20in%20the%20Area%20Following%20a%20Bend&rft.jtitle=Power%20technology%20and%20engineering&rft.au=Boltenko,%20%C3%89.%20A.&rft.date=2018&rft.volume=51&rft.issue=5&rft.spage=562&rft.epage=567&rft.pages=562-567&rft.issn=1570-145X&rft.eissn=1570-1468&rft_id=info:doi/10.1007/s10749-018-0874-8&rft_dat=%3Cproquest_osti_%3E2006847514%3C/proquest_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2698-d857d24f35db1b4a6b6f1f4af445ccf4398cc40e311da399a7565af3954aaf203%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2006847514&rft_id=info:pmid/&rfr_iscdi=true