Approach, Technical Success, Complications, and Stent Patency of Sharp Recanalization for the Treatment of Chronic Venous Occlusive Disease: Experience in 123 Patients
Purpose To report the technical success and complications following sharp recanalization of chronic venous occlusions. Materials and Methods A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization...
Saved in:
Published in: | Cardiovascular and interventional radiology 2019-02, Vol.42 (2), p.205-212 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To report the technical success and complications following sharp recanalization of chronic venous occlusions.
Materials and Methods
A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization of chronic venous occlusions. The etiologies of occlusion were chronic deep venous thrombosis (
n
= 43; 35.0%), prior central venous access (
n
= 39; 31.7%), indwelling cardiac leads (
n
= 21; 17.1%), and occluded venous stents (
n
= 20; 16.3%). The sites of venous occlusion included 59/123 (48.0%) thoracic central veins, 37 (30.1%) non-thoracic central veins, and 27 (22.0%) peripheral veins. Median length of occlusion was 3.2 ± 1.4 cm (range 1.3–10.9 cm).
Results
Sharp recanalization was most commonly attempted with transseptal needles in 108/123 (87.8%), with a mean number of 1.2 ± 0.4 crossing devices per patient (range 1–4 devices). Targeting devices included a loop snare (
n
= 92; 74.8%), partially deployed Wallstent (
n
= 21; 17.1%), partially deployed Amplatzer vascular plug (
n
= 8; 6.5%), and an angioplasty balloon (
n
= 3; 2.4%). Technical success was achieved in 111 (90.2%) patients. There were 3 (2.4%) severe, 1 (0.8%) moderate, and 7 (5.7%) minor adverse events. Severe adverse events included 1 case each of pericardial tamponade, hemothorax, and inferior vena cava filter occlusion. 88 (71.5%) patients had venous stents placed; at the last follow-up examination, 68/86 (79.0%) stents were patent.
Conclusion
Sharp recanalization has a high technical success and low rate of adverse events in the recanalization of chronic venous occlusions. |
---|---|
ISSN: | 0174-1551 1432-086X |
DOI: | 10.1007/s00270-018-2090-1 |