Thermal performance of three naturally ventilated public buildings in which the wind tower is an important architectural freature is studied. One of the three builidings as well as it's wind tower is instrumented for temperature, relative humidity and airflow velocity measurements, and the othe...

Full description

Saved in:
Bibliographic Details
Published in:Solar energy 1991, Vol.47 (2), p.97-106
Main Authors: Yaghoubi, M.A., Sabzevari, A., Golneshan, A.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Thermal performance of three naturally ventilated public buildings in which the wind tower is an important architectural freature is studied. One of the three builidings as well as it's wind tower is instrumented for temperature, relative humidity and airflow velocity measurements, and the other two are instrumented for temperature measurement. The results have led to a discussion concerning the degree of wind tower effectiveness in achieving thermal comfort.
ISSN:0038-092X
1471-1257
DOI:10.1016/0038-092X(91)90040-4