Loading…
Experimental verification of bremsstrahlung production and dosimetry predictions for 15. 5 MeV electrons
In this paper the radiation produced by a 15.5-MeV mono-energetic electron beam incident on optimized and non-optimized bremsstrahlung targets is characterized using the ITS Monte Carlo code and measurements with equilibrated and non-equilibrated TLD dosimetry. Comparisons between calculations and m...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this paper the radiation produced by a 15.5-MeV mono-energetic electron beam incident on optimized and non-optimized bremsstrahlung targets is characterized using the ITS Monte Carlo code and measurements with equilibrated and non-equilibrated TLD dosimetry. Comparisons between calculations and measurements verify the calculations and demonstrate that the code can be used to predict both bremsstrahlung production and TLD response for radiation fields that are characteristic of those produced by pulsed simulators of gamma rays. At optimum bremsstrahlung production, the predicted total forward radiation fluence detected in equilibrated TLD dosimetry agrees with that measured with the {plus minus} 6% uncertainty of the measurement. The absolute comparisons made here provide independent confirmation of the validity of the TLD calibration for photon fields characteristic of gamma-ray simulators. The empirical Martin equation, which is often used to calculate radiation dose from optimized bremsstrahlung targets, is examined, and its range of validity is established from the data presented. |
---|---|
ISSN: | 0018-9499 1558-1578 |
DOI: | 10.1109/23.124089 |