Nondestructive evaluation and real-time monitoring of laser surface hardening
An infrared process monitor was used to monitor in real-time the infrared emissions during laser surface hardening of ferrous alloys. The signals from the monitor were correlated with the hardness and case depth of the laser-treated tracks. Test data show that a linear relationship exists between th...
Saved in:
Published in: | Journal of materials processing technology 2008-09, Vol.206 (1), p.120-125 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33 |
---|---|
cites | cdi_FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33 |
container_end_page | 125 |
container_issue | 1 |
container_start_page | 120 |
container_title | Journal of materials processing technology |
container_volume | 206 |
creator | Xu, Zhiyue Leong, Keng H. Reed, Claude B. |
description | An infrared process monitor was used to monitor in real-time the infrared emissions during laser surface hardening of ferrous alloys. The signals from the monitor were correlated with the hardness and case depth of the laser-treated tracks. Test data show that a linear relationship exists between the monitor output DC level voltage and hardness up to the maximum hardness possible and also between the monitor output DC level voltage and case depth. This simple relationship makes it easy to monitor process hardness, case depth and quality of laser heat-treated workpiece. A calibration test on a prototypic material can be used to determine the upper and lower bounds of the voltage signals for a sound quality treatment. In-process monitoring or real-time nondestructive measurement of the hardness and depth of the laser transformation hardened case can then be achieved. The monitor is also capable of tracking changes in surface quality or flatness of the part that is being treated. |
doi_str_mv | 10.1016/j.jmatprotec.2007.12.030 |
format | article |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_osti_scitechconnect_935657</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0924013607013635</els_id><sourcerecordid>33572949</sourcerecordid><originalsourceid>FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33</originalsourceid><addsrcrecordid>eNqFkDtPxDAQhFOAxPH4D6ahS1jblzgpAfGSeDRQW4694XxKbLCdk_j3-BQkSqotdmY08xUFoVBRoM3lttpOKn0Gn1BXDEBUlFXA4aBYQcfWJVDeHBXHMW4BqIC2XRXPL94ZjCnMOtkdEtypcVbJekeUMySgGstkJySTdzb5YN0H8QMZVcRA4hwGpZFsVDDo8uu0OBzUGPHs954U73e3bzcP5dPr_ePN1VOpuahTSRsmBHDFjWk61tVcaQY9GsPbtuVQ96anHayN6rHhDaspQA29HgYhONCB85PifMn1MVkZtc2DN9o7hzrJjtdNLbLmYtFkHl9znignGzWOo3Lo5yg5rwXr1l0WtotQBx9jwEF-Bjup8C0pyD1XuZV_XOWeq6RMZq7Zer1YMY_dWQz7Lug0Ghv2VYy3_4f8AJV7iRA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>33572949</pqid></control><display><type>article</type><title>Nondestructive evaluation and real-time monitoring of laser surface hardening</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Xu, Zhiyue ; Leong, Keng H. ; Reed, Claude B.</creator><creatorcontrib>Xu, Zhiyue ; Leong, Keng H. ; Reed, Claude B. ; Argonne National Lab. (ANL), Argonne, IL (United States)</creatorcontrib><description>An infrared process monitor was used to monitor in real-time the infrared emissions during laser surface hardening of ferrous alloys. The signals from the monitor were correlated with the hardness and case depth of the laser-treated tracks. Test data show that a linear relationship exists between the monitor output DC level voltage and hardness up to the maximum hardness possible and also between the monitor output DC level voltage and case depth. This simple relationship makes it easy to monitor process hardness, case depth and quality of laser heat-treated workpiece. A calibration test on a prototypic material can be used to determine the upper and lower bounds of the voltage signals for a sound quality treatment. In-process monitoring or real-time nondestructive measurement of the hardness and depth of the laser transformation hardened case can then be achieved. The monitor is also capable of tracking changes in surface quality or flatness of the part that is being treated.</description><identifier>ISSN: 0924-0136</identifier><identifier>DOI: 10.1016/j.jmatprotec.2007.12.030</identifier><language>eng</language><publisher>United States: Elsevier B.V</publisher><subject>Ferrous alloys ; HARDNESS ; Infrared sensors ; IRON ALLOYS ; Laser surface hardening ; LASER-RADIATION HEATING ; MATERIALS SCIENCE ; MONITORING ; MONITORS ; NONDESTRUCTIVE TESTING ; Process monitoring ; REAL TIME SYSTEMS ; SURFACE HARDENING</subject><ispartof>Journal of materials processing technology, 2008-09, Vol.206 (1), p.120-125</ispartof><rights>2007 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33</citedby><cites>FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27922,27923</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/935657$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Xu, Zhiyue</creatorcontrib><creatorcontrib>Leong, Keng H.</creatorcontrib><creatorcontrib>Reed, Claude B.</creatorcontrib><creatorcontrib>Argonne National Lab. (ANL), Argonne, IL (United States)</creatorcontrib><title>Nondestructive evaluation and real-time monitoring of laser surface hardening</title><title>Journal of materials processing technology</title><description>An infrared process monitor was used to monitor in real-time the infrared emissions during laser surface hardening of ferrous alloys. The signals from the monitor were correlated with the hardness and case depth of the laser-treated tracks. Test data show that a linear relationship exists between the monitor output DC level voltage and hardness up to the maximum hardness possible and also between the monitor output DC level voltage and case depth. This simple relationship makes it easy to monitor process hardness, case depth and quality of laser heat-treated workpiece. A calibration test on a prototypic material can be used to determine the upper and lower bounds of the voltage signals for a sound quality treatment. In-process monitoring or real-time nondestructive measurement of the hardness and depth of the laser transformation hardened case can then be achieved. The monitor is also capable of tracking changes in surface quality or flatness of the part that is being treated.</description><subject>Ferrous alloys</subject><subject>HARDNESS</subject><subject>Infrared sensors</subject><subject>IRON ALLOYS</subject><subject>Laser surface hardening</subject><subject>LASER-RADIATION HEATING</subject><subject>MATERIALS SCIENCE</subject><subject>MONITORING</subject><subject>MONITORS</subject><subject>NONDESTRUCTIVE TESTING</subject><subject>Process monitoring</subject><subject>REAL TIME SYSTEMS</subject><subject>SURFACE HARDENING</subject><issn>0924-0136</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkDtPxDAQhFOAxPH4D6ahS1jblzgpAfGSeDRQW4694XxKbLCdk_j3-BQkSqotdmY08xUFoVBRoM3lttpOKn0Gn1BXDEBUlFXA4aBYQcfWJVDeHBXHMW4BqIC2XRXPL94ZjCnMOtkdEtypcVbJekeUMySgGstkJySTdzb5YN0H8QMZVcRA4hwGpZFsVDDo8uu0OBzUGPHs954U73e3bzcP5dPr_ePN1VOpuahTSRsmBHDFjWk61tVcaQY9GsPbtuVQ96anHayN6rHhDaspQA29HgYhONCB85PifMn1MVkZtc2DN9o7hzrJjtdNLbLmYtFkHl9znignGzWOo3Lo5yg5rwXr1l0WtotQBx9jwEF-Bjup8C0pyD1XuZV_XOWeq6RMZq7Zer1YMY_dWQz7Lug0Ghv2VYy3_4f8AJV7iRA</recordid><startdate>20080912</startdate><enddate>20080912</enddate><creator>Xu, Zhiyue</creator><creator>Leong, Keng H.</creator><creator>Reed, Claude B.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>OTOTI</scope></search><sort><creationdate>20080912</creationdate><title>Nondestructive evaluation and real-time monitoring of laser surface hardening</title><author>Xu, Zhiyue ; Leong, Keng H. ; Reed, Claude B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Ferrous alloys</topic><topic>HARDNESS</topic><topic>Infrared sensors</topic><topic>IRON ALLOYS</topic><topic>Laser surface hardening</topic><topic>LASER-RADIATION HEATING</topic><topic>MATERIALS SCIENCE</topic><topic>MONITORING</topic><topic>MONITORS</topic><topic>NONDESTRUCTIVE TESTING</topic><topic>Process monitoring</topic><topic>REAL TIME SYSTEMS</topic><topic>SURFACE HARDENING</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xu, Zhiyue</creatorcontrib><creatorcontrib>Leong, Keng H.</creatorcontrib><creatorcontrib>Reed, Claude B.</creatorcontrib><creatorcontrib>Argonne National Lab. (ANL), Argonne, IL (United States)</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>OSTI.GOV</collection><jtitle>Journal of materials processing technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xu, Zhiyue</au><au>Leong, Keng H.</au><au>Reed, Claude B.</au><aucorp>Argonne National Lab. (ANL), Argonne, IL (United States)</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Nondestructive evaluation and real-time monitoring of laser surface hardening</atitle><jtitle>Journal of materials processing technology</jtitle><date>2008-09-12</date><risdate>2008</risdate><volume>206</volume><issue>1</issue><spage>120</spage><epage>125</epage><pages>120-125</pages><issn>0924-0136</issn><abstract>An infrared process monitor was used to monitor in real-time the infrared emissions during laser surface hardening of ferrous alloys. The signals from the monitor were correlated with the hardness and case depth of the laser-treated tracks. Test data show that a linear relationship exists between the monitor output DC level voltage and hardness up to the maximum hardness possible and also between the monitor output DC level voltage and case depth. This simple relationship makes it easy to monitor process hardness, case depth and quality of laser heat-treated workpiece. A calibration test on a prototypic material can be used to determine the upper and lower bounds of the voltage signals for a sound quality treatment. In-process monitoring or real-time nondestructive measurement of the hardness and depth of the laser transformation hardened case can then be achieved. The monitor is also capable of tracking changes in surface quality or flatness of the part that is being treated.</abstract><cop>United States</cop><pub>Elsevier B.V</pub><doi>10.1016/j.jmatprotec.2007.12.030</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0924-0136 |
ispartof | Journal of materials processing technology, 2008-09, Vol.206 (1), p.120-125 |
issn | 0924-0136 |
language | eng |
recordid | cdi_osti_scitechconnect_935657 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Ferrous alloys HARDNESS Infrared sensors IRON ALLOYS Laser surface hardening LASER-RADIATION HEATING MATERIALS SCIENCE MONITORING MONITORS NONDESTRUCTIVE TESTING Process monitoring REAL TIME SYSTEMS SURFACE HARDENING |
title | Nondestructive evaluation and real-time monitoring of laser surface hardening |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T15%3A28%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Nondestructive%20evaluation%20and%20real-time%20monitoring%20of%20laser%20surface%20hardening&rft.jtitle=Journal%20of%20materials%20processing%20technology&rft.au=Xu,%20Zhiyue&rft.aucorp=Argonne%20National%20Lab.%20(ANL),%20Argonne,%20IL%20(United%20States)&rft.date=2008-09-12&rft.volume=206&rft.issue=1&rft.spage=120&rft.epage=125&rft.pages=120-125&rft.issn=0924-0136&rft_id=info:doi/10.1016/j.jmatprotec.2007.12.030&rft_dat=%3Cproquest_osti_%3E33572949%3C/proquest_osti_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c375t-1627703a3dd692953ac20bedd3888305bdb1904dabe6362510050bcff77301f33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=33572949&rft_id=info:pmid/&rfr_iscdi=true |