A Comparison of Experimental Results and FLUENT Simulations for Void-Fraction Distribution in a Two-Phase System
This work focuses on the comparison between the results obtained by gamma-ray tomography (experimental) and the FLUENT code (simulation). The physical property targeted here is the void distribution in the riser leg of a mercury-nitrogen flow system. Multiplicative algebraic reconstruction technique...
Saved in:
Published in: | Nuclear technology 2008-09, Vol.163 (3), p.426-434 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This work focuses on the comparison between the results obtained by gamma-ray tomography (experimental) and the FLUENT code (simulation). The physical property targeted here is the void distribution in the riser leg of a mercury-nitrogen flow system. Multiplicative algebraic reconstruction technique (MART) algorithms have been used for the tomographic image reconstruction. A comparison of the predicted and the experimental results shows that experimental numbers are consistently lower than FLUENT predictions. |
---|---|