Loading…

Spiral CT image deblurring for cochlear implantation

Cochlear implantation is the standard treatment for profound hearing loss, Preimplantation and postimplantation spiral computed tomography (CT) is essential in several key clinical and research aspects. The maximum image resolution with commercial spiral CT scanners is insufficient to define clearly...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on medical imaging 1998-04, Vol.17 (2), p.251-262
Main Authors: Ge Wang, Vannier, M.W., Skinner, M.W., Cavalcanti, M.G.P., Harding, G.W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Cochlear implantation is the standard treatment for profound hearing loss, Preimplantation and postimplantation spiral computed tomography (CT) is essential in several key clinical and research aspects. The maximum image resolution with commercial spiral CT scanners is insufficient to define clearly anatomical features and implant electrode positions in the inner ear, In this paper, the authors develop an expectation maximization (EM)-like iterative deblurring algorithm to achieve spiral CT image super-resolution for cochlear implantation, assuming a spatially invariant linear spiral CT system with a three-dimensional (3-D) separable Gaussian point spread function (PSF). The authors experimentally validate the 3-D Gaussian blurring model via phantom measurement and profile fitting. The imaging process is further expressed as convolution of an isotropic 3-D Gaussian PSF and a blurred underlying volumetric image. Under practical conditions, an oblique reconstructed section is approximated as convolution of an isotropic two dimensional (2-D) Gaussian PSF and the corresponding actual cross section. The spiral CT image deblurring algorithm is formulated with sieve and resolution kernels for suppressing noise and edge artifacts. A typical cochlear cross section is used for evaluation, demonstrating a resolution gain up to 30%-40% according to the correlation criterion. Physical phantoms, preimplantation and postimplantation patients are reconstructed into volumes of 0.1-mm cubic voxels. The patient images are digitally unwrapped along the central axis of the cochlea and the implanted electrode array respectively, then oblique sections orthogonal to the central axis formed. After deblurring, representation of structural features is substantially improved in all the cases.
ISSN:0278-0062
1558-254X
DOI:10.1109/42.700737