Loading…

Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography

A technique for the sensitive and convenient determination of phosphatidylcholine hydroperoxides was developed that uses coulometric electrochemical detection in a high-performance liquid chromatographic analysis. The detection limit for phosphatidylcholine hydroperoxides by this method was 20 pmol...

Full description

Saved in:
Bibliographic Details
Published in:Bioscience, biotechnology, and biochemistry biotechnology, and biochemistry, 1997-01, Vol.61 (1), p.191-193
Main Authors: Arai, Hirofumi, Mohri, Satoshi, Suzuki, Tetsuya, Takama, Kozo, Terao, Junji
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4751-53506d912c54391452b2719d6ea21eb37f77a66358b482f1b9a15fd1215db2823
cites
container_end_page 193
container_issue 1
container_start_page 191
container_title Bioscience, biotechnology, and biochemistry
container_volume 61
creator Arai, Hirofumi
Mohri, Satoshi
Suzuki, Tetsuya
Takama, Kozo
Terao, Junji
description A technique for the sensitive and convenient determination of phosphatidylcholine hydroperoxides was developed that uses coulometric electrochemical detection in a high-performance liquid chromatographic analysis. The detection limit for phosphatidylcholine hydroperoxides by this method was 20 pmol at a signal-to-noise ratio of 3. The glutathione-dependent phospholipid hydroperoxide-reducing activity of fresh human plasma was ascertained by this method.
doi_str_mv 10.1271/bbb.61.191
format article
fullrecord <record><control><sourceid>proquest_pasca</sourceid><recordid>TN_cdi_pascalfrancis_primary_2610386</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3121799511</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4751-53506d912c54391452b2719d6ea21eb37f77a66358b482f1b9a15fd1215db2823</originalsourceid><addsrcrecordid>eNptkE1r20AQhpeSQh23l_4CQXsKyNHsl6RjcZw4YGgP7XnZlVbWGkkj78q0-vddx05OOQ28PPMO8xDyFbIV0BzujTErCSso4QNZAON5Kkue35BFVoJMCy7gE7kN4ZBlMRCwIMMaTx32dvKuSjadrSaPVWt7V-kuebBTDBwOCTbJrxbD2GLnRlcn27n2OFqP_1xtQ2LmZOv2bRqTBn2vh8omO3c8RXLdeuz1hHuvx3b-TD42ugv2y3UuyZ_Hze_1Nt39fHpe_9ilFc8FpIKJTNYl0EpwVgIX1MTvylpaTcEaljd5rqVkojC8oA2YUoNoaqAgakMLypbk26V39Hg82TCpA578EE8q4LzkVDIuI3V3oSqPIXjbqNG7XvtZQabOPlX0qSSo6DPC36-VOkQ5jY9fuvC2QSVkrDh3igvmhhcVf9F3tZr03KF_3WHv1P8HBqeIHg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1449426346</pqid></control><display><type>article</type><title>Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography</title><source>Electronic Journals Library</source><source>Oxford Journals Online</source><creator>Arai, Hirofumi ; Mohri, Satoshi ; Suzuki, Tetsuya ; Takama, Kozo ; Terao, Junji</creator><creatorcontrib>Arai, Hirofumi ; Mohri, Satoshi ; Suzuki, Tetsuya ; Takama, Kozo ; Terao, Junji</creatorcontrib><description>A technique for the sensitive and convenient determination of phosphatidylcholine hydroperoxides was developed that uses coulometric electrochemical detection in a high-performance liquid chromatographic analysis. The detection limit for phosphatidylcholine hydroperoxides by this method was 20 pmol at a signal-to-noise ratio of 3. The glutathione-dependent phospholipid hydroperoxide-reducing activity of fresh human plasma was ascertained by this method.</description><identifier>ISSN: 0916-8451</identifier><identifier>EISSN: 1347-6947</identifier><identifier>DOI: 10.1271/bbb.61.191</identifier><language>eng</language><publisher>Tokyo: Taylor &amp; Francis</publisher><subject>Analytical, structural and metabolic biochemistry ; Biological and medical sciences ; coulometric electrochemical detection ; Fundamental and applied biological sciences. Psychology ; Glycerolipids, phospholipids ; HPLC ; Lipids ; Other biological molecules ; phospholipid hydroperoxide</subject><ispartof>Bioscience, biotechnology, and biochemistry, 1997-01, Vol.61 (1), p.191-193</ispartof><rights>Copyright 1997 Taylor and Francis Group LLC 1997</rights><rights>1997 INIST-CNRS</rights><rights>Copyright Japan Science and Technology Agency 1997</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4751-53506d912c54391452b2719d6ea21eb37f77a66358b482f1b9a15fd1215db2823</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2610386$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Arai, Hirofumi</creatorcontrib><creatorcontrib>Mohri, Satoshi</creatorcontrib><creatorcontrib>Suzuki, Tetsuya</creatorcontrib><creatorcontrib>Takama, Kozo</creatorcontrib><creatorcontrib>Terao, Junji</creatorcontrib><title>Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography</title><title>Bioscience, biotechnology, and biochemistry</title><description>A technique for the sensitive and convenient determination of phosphatidylcholine hydroperoxides was developed that uses coulometric electrochemical detection in a high-performance liquid chromatographic analysis. The detection limit for phosphatidylcholine hydroperoxides by this method was 20 pmol at a signal-to-noise ratio of 3. The glutathione-dependent phospholipid hydroperoxide-reducing activity of fresh human plasma was ascertained by this method.</description><subject>Analytical, structural and metabolic biochemistry</subject><subject>Biological and medical sciences</subject><subject>coulometric electrochemical detection</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Glycerolipids, phospholipids</subject><subject>HPLC</subject><subject>Lipids</subject><subject>Other biological molecules</subject><subject>phospholipid hydroperoxide</subject><issn>0916-8451</issn><issn>1347-6947</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNptkE1r20AQhpeSQh23l_4CQXsKyNHsl6RjcZw4YGgP7XnZlVbWGkkj78q0-vddx05OOQ28PPMO8xDyFbIV0BzujTErCSso4QNZAON5Kkue35BFVoJMCy7gE7kN4ZBlMRCwIMMaTx32dvKuSjadrSaPVWt7V-kuebBTDBwOCTbJrxbD2GLnRlcn27n2OFqP_1xtQ2LmZOv2bRqTBn2vh8omO3c8RXLdeuz1hHuvx3b-TD42ugv2y3UuyZ_Hze_1Nt39fHpe_9ilFc8FpIKJTNYl0EpwVgIX1MTvylpaTcEaljd5rqVkojC8oA2YUoNoaqAgakMLypbk26V39Hg82TCpA578EE8q4LzkVDIuI3V3oSqPIXjbqNG7XvtZQabOPlX0qSSo6DPC36-VOkQ5jY9fuvC2QSVkrDh3igvmhhcVf9F3tZr03KF_3WHv1P8HBqeIHg</recordid><startdate>19970101</startdate><enddate>19970101</enddate><creator>Arai, Hirofumi</creator><creator>Mohri, Satoshi</creator><creator>Suzuki, Tetsuya</creator><creator>Takama, Kozo</creator><creator>Terao, Junji</creator><general>Taylor &amp; Francis</general><general>Japan Society for Bioscience Biotechnology and Agrochemistry</general><general>Oxford University Press</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19970101</creationdate><title>Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography</title><author>Arai, Hirofumi ; Mohri, Satoshi ; Suzuki, Tetsuya ; Takama, Kozo ; Terao, Junji</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4751-53506d912c54391452b2719d6ea21eb37f77a66358b482f1b9a15fd1215db2823</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Analytical, structural and metabolic biochemistry</topic><topic>Biological and medical sciences</topic><topic>coulometric electrochemical detection</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Glycerolipids, phospholipids</topic><topic>HPLC</topic><topic>Lipids</topic><topic>Other biological molecules</topic><topic>phospholipid hydroperoxide</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Arai, Hirofumi</creatorcontrib><creatorcontrib>Mohri, Satoshi</creatorcontrib><creatorcontrib>Suzuki, Tetsuya</creatorcontrib><creatorcontrib>Takama, Kozo</creatorcontrib><creatorcontrib>Terao, Junji</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Bioscience, biotechnology, and biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Arai, Hirofumi</au><au>Mohri, Satoshi</au><au>Suzuki, Tetsuya</au><au>Takama, Kozo</au><au>Terao, Junji</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography</atitle><jtitle>Bioscience, biotechnology, and biochemistry</jtitle><date>1997-01-01</date><risdate>1997</risdate><volume>61</volume><issue>1</issue><spage>191</spage><epage>193</epage><pages>191-193</pages><issn>0916-8451</issn><eissn>1347-6947</eissn><abstract>A technique for the sensitive and convenient determination of phosphatidylcholine hydroperoxides was developed that uses coulometric electrochemical detection in a high-performance liquid chromatographic analysis. The detection limit for phosphatidylcholine hydroperoxides by this method was 20 pmol at a signal-to-noise ratio of 3. The glutathione-dependent phospholipid hydroperoxide-reducing activity of fresh human plasma was ascertained by this method.</abstract><cop>Tokyo</cop><pub>Taylor &amp; Francis</pub><doi>10.1271/bbb.61.191</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0916-8451
ispartof Bioscience, biotechnology, and biochemistry, 1997-01, Vol.61 (1), p.191-193
issn 0916-8451
1347-6947
language eng
recordid cdi_pascalfrancis_primary_2610386
source Electronic Journals Library; Oxford Journals Online
subjects Analytical, structural and metabolic biochemistry
Biological and medical sciences
coulometric electrochemical detection
Fundamental and applied biological sciences. Psychology
Glycerolipids, phospholipids
HPLC
Lipids
Other biological molecules
phospholipid hydroperoxide
title Coulometric Electrochemical Detection of Phospholipid Hydroperoxides by High-performance Liquid Chromatography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T06%3A43%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pasca&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Coulometric%20Electrochemical%20Detection%20of%20Phospholipid%20Hydroperoxides%20by%20High-performance%20Liquid%20Chromatography&rft.jtitle=Bioscience,%20biotechnology,%20and%20biochemistry&rft.au=Arai,%20Hirofumi&rft.date=1997-01-01&rft.volume=61&rft.issue=1&rft.spage=191&rft.epage=193&rft.pages=191-193&rft.issn=0916-8451&rft.eissn=1347-6947&rft_id=info:doi/10.1271/bbb.61.191&rft_dat=%3Cproquest_pasca%3E3121799511%3C/proquest_pasca%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4751-53506d912c54391452b2719d6ea21eb37f77a66358b482f1b9a15fd1215db2823%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1449426346&rft_id=info:pmid/&rfr_iscdi=true