Loading…

Experimental investigation of the streaming potential hypothesis for ionic polymer transducers in sensing

Ionic polymer transducers (IPTs) are ionomers that are plated with conductive media such as metals, leading to capacitive behavior. IPTs exhibit bending deformation when a voltage difference is applied across the surfaces of the transducer, thus displaying actuation. A current is generated when they...

Full description

Saved in:
Bibliographic Details
Published in:Smart materials and structures 2013-03, Vol.22 (3), p.35020-1-10
Main Authors: Kocer, Bilge, Weiland, Lisa Mauck
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Ionic polymer transducers (IPTs) are ionomers that are plated with conductive media such as metals, leading to capacitive behavior. IPTs exhibit bending deformation when a voltage difference is applied across the surfaces of the transducer, thus displaying actuation. A current is generated when they are deformed, thus exhibiting sensing. However, the mechanisms responsible for actuation and sensing differ; research to date has focused predominantly on actuation, while identification of the dominant mechanism responsible for IPT sensing remains an open topic. The goal of this work is to initiate experimental investigations of the streaming potential hypothesis for IPT sensing. This hypothesis argues that the presence of unbound counter-ions within the hydrophilic phase of an ionic polymer behaves as an electrolyte in the presence of the electrode. Thus, as per classic streaming potential analyses, relative motion of the electrolyte with respect to the electrode will result in the evolution of a streaming potential. According to this hypothesis, the extent of communication between the electrode and electrolyte becomes important in the evolution of an electrical signal. This study experimentally explores the effect of electrode architecture on the sensing response where the IPTs are prepared via the direct assembly process (DAP). The DAP is selected because it enables control over the fabrication of the electrode structure. In this study, cantilevered IPT samples having different electrode composition are tested under several step input tip displacements. The experimental outcomes are consistent with predicted trends via streaming potential theory.
ISSN:0964-1726
1361-665X
DOI:10.1088/0964-1726/22/3/035020