Sensorless-control of the synchronous reluctance motor
In this paper a sensorless closed-loop speed control for the synchronous reluctance motor is presented. The sensorless control is based on the torque vector control algorithm. It has been implemented using a high-speed digital processor DSP96002. Experimental results for a 120 W axially-laminated sy...
Saved in:
Published in: | IEEE transactions on industry applications 1994-05, Vol.30 (3), p.673-682 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this paper a sensorless closed-loop speed control for the synchronous reluctance motor is presented. The sensorless control is based on the torque vector control algorithm. It has been implemented using a high-speed digital processor DSP96002. Experimental results for a 120 W axially-laminated synchronous reluctance motor are presented and compared with operation with a speed sensor and simulations. A base speed range of 400-1500 RPM has been achieved. The top speed was extended to 2750 RPM using flux-weakening. The drive can be applied a full-load step-change within this speed range without losing synchronism.< > |
---|---|
ISSN: | 0093-9994 1939-9367 |
DOI: | 10.1109/28.293716 |