In this paper a sensorless closed-loop speed control for the synchronous reluctance motor is presented. The sensorless control is based on the torque vector control algorithm. It has been implemented using a high-speed digital processor DSP96002. Experimental results for a 120 W axially-laminated sy...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on industry applications 1994-05, Vol.30 (3), p.673-682
Main Authors: Lagerquist, R., Boldea, I., Miller, T.J.E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this paper a sensorless closed-loop speed control for the synchronous reluctance motor is presented. The sensorless control is based on the torque vector control algorithm. It has been implemented using a high-speed digital processor DSP96002. Experimental results for a 120 W axially-laminated synchronous reluctance motor are presented and compared with operation with a speed sensor and simulations. A base speed range of 400-1500 RPM has been achieved. The top speed was extended to 2750 RPM using flux-weakening. The drive can be applied a full-load step-change within this speed range without losing synchronism.< >