A control method for GTO PWM inverter parallel-set operation and a new protection system for prevention of short-circuit faults caused by turn-off failure, both to realize a high-power drive system are described. Timing control of GTO gate pulse command provided by a feedback loop, and a reactor at...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on industry applications 1987-03, Vol.IA-23 (2), p.263-269
Main Authors: Hashii, Makoto, Kousaka, Kenji, Kaimoto, Masahiro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A control method for GTO PWM inverter parallel-set operation and a new protection system for prevention of short-circuit faults caused by turn-off failure, both to realize a high-power drive system are described. Timing control of GTO gate pulse command provided by a feedback loop, and a reactor at the output of the inverter can minimize the cross current flowing between inverters and can balance the output current of each inverter in inverter parallel-set operation. This method eliminates the necessity of selecting GTO's of equal characteristics, and can apply to parallel-set operation of three or more inverters. The new protection system judges the on and off states of the GTO from the GTO gate-cathode voltage and detects turn-off failure of the GTO. This method positively stops the inverter system safely and reliably upon turn-off failure of the GTO. Experiments are carried out on a 30-kVA inverter and two sets of 450-kVA GTO inverters.
ISSN:0093-9994
1939-9367
DOI:10.1109/TIA.1987.4504901