Loading…

Accelerating whole-heart 3D T2 mapping: Impact of undersampling strategies and reconstruction techniques

We aim to determine an advantageous approach for the acceleration of high spatial resolution 3D cardiac T2 relaxometry data by comparing the performance of different undersampling patterns and reconstruction methods over a range of acceleration rates. Multi-volume 3D high-resolution cardiac images w...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2021-09, Vol.16 (9), p.e0252777-e0252777
Main Authors: Zhu, Dan, Ding, Haiyan, Zviman, M. Muz, Halperin, Henry, Schär, Michael, Herzka, Daniel A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We aim to determine an advantageous approach for the acceleration of high spatial resolution 3D cardiac T2 relaxometry data by comparing the performance of different undersampling patterns and reconstruction methods over a range of acceleration rates. Multi-volume 3D high-resolution cardiac images were acquired fully and undersampled retrospectively using 1) optimal CAIPIRINHA and 2) a variable density random (VDR) sampling. Data were reconstructed using 1) multi-volume sensitivity encoding (SENSE), 2) joint-sparsity SENSE and 3) model-based SENSE. Four metrics were calculated on 3 naïve swine and 8 normal human subjects over a whole left-ventricular region of interest: root-mean-square error (RMSE) of image signal intensity, RMSE of T2, the bias of mean T2, and standard deviation (SD) of T2. Fully sampled data and volume-by-volume SENSE with standard equally spaced undersampling were used as references. The Jaccard index calculated from one swine with acute myocardial infarction (MI) was used to demonstrate preservation of segmentation of edematous tissues with elevated T2. In naïve swine and normal human subjects, all methods had similar performance when the net reduction factor (R.sub.net) 2.5, while VDR sampling with the joint-sparsity SENSE had the lowest bias of mean T2 (0.0-1.1ms) when R.sub.net >3. The RMSEs of parametric T2 values (9.2%-24.6%) were larger than for image signal intensities (5.2%-18.4%). In the swine with MI, VDR sampling with either joint-sparsity or model-based SENSE showed consistently higher Jaccard index for all R.sub.net (0.71-0.50) than volume-by-volume SENSE (0.68-0.30). Retrospective exploration of undersampling and reconstruction in 3D whole-heart T2 parametric mapping revealed that maps were more sensitive to undersampling than images, presenting a more stringent limiting factor on R.sub.net . The combination of VDR sampling patterns with model-based or joint-sparsity SENSE reconstructions were more robust for R.sub.net >3.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0252777