Loading…

Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study

The goal of our study was to investigate the relative and absolute intra-rater and inter-rater reliability of ultrasound assessment of patellar tendon (PT) thickness assessed over four locations, in track cyclists and soccer players. Fifteen male elite track cyclists and 15 male elite soccer players...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2022-07, Vol.17 (7), p.e0270871-e0270871
Main Authors: Klich, Sebastian, Kosendiak, Aureliusz, Krymski, Igor, Kawczynski, Adam, Madeleine, Pascal, Fernández-de-las-Peñas, Cesar
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323
cites cdi_FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323
container_end_page e0270871
container_issue 7
container_start_page e0270871
container_title PloS one
container_volume 17
creator Klich, Sebastian
Kosendiak, Aureliusz
Krymski, Igor
Kawczynski, Adam
Madeleine, Pascal
Fernández-de-las-Peñas, Cesar
description The goal of our study was to investigate the relative and absolute intra-rater and inter-rater reliability of ultrasound assessment of patellar tendon (PT) thickness assessed over four locations, in track cyclists and soccer players. Fifteen male elite track cyclists and 15 male elite soccer players participated. Tendon thickness was measured over 4 locations placed at 5-10-15-20 mm inferior to the apex of the patella by two experienced examiners. Each examiner took two US images for the test measurements with a 10-min rest period. After a 30-min period, the subjects underwent a retest measurements that were also repeated 1-week after. A two-way analysis of variance revealed a significant group x location interaction on PT thickness for Examiner 1 (p = .001, [eta].sup.2 = .81) and Examiner 2 (p = 0.001, [eta].sup.2 = 0.78). Intra-rater reliability ranged from good to excellent (ICC.sub.2,k [greater than or equal to] 0.75), whereas inter-rater reliability was good (ICC.sub.2,k [greater than or equal to] 0.75) in both groups. Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT (corresponding to 15 and 20 mm) can be considered the most reliable spot to measure PT thickness. The PT thickness was larger among track cyclists than soccer players, with larger differences over the distal location (15 mm). Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT corresponding to 15 mm and 20 mm can be considered the most reliable area to measure PT thickness.
doi_str_mv 10.1371/journal.pone.0270871
format article
fullrecord <record><control><sourceid>gale_plos_</sourceid><recordid>TN_cdi_plos_journals_2686271702</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A709256513</galeid><doaj_id>oai_doaj_org_article_52fddddb24ec49719bfc1332580ff739</doaj_id><sourcerecordid>A709256513</sourcerecordid><originalsourceid>FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323</originalsourceid><addsrcrecordid>eNqNk9-O1CAUxhujcdfRNzCRxMToxYwUWlq8MJls_DPJJpuo6y2hFDrMMjAL1NhH8W2lM9VszV5ILyjw-z44B06WPc_hKsdV_nbnem-5WR2clSuIKlhX-YPsPKcYLQmC-OGd_7PsSQg7CEtcE_I4O8NlVVOMyXn269pEz4PrbQv0nnfadsApcOBRGsM9iNK2zoK41eLGyhCAtkAaHSUIB69tBEktboAYhNEhBsCTz7TuhJAeHAwfpA_vwNombaKXPnn7I5jG0k9jn1S80Uk6gBD7dniaPVLcBPls6hfZ9ccP3y4-Ly-vPm0u1pdLQQiNy4IoXDeqkDksJcW0yEUBW1JiQWrIJeSCwgK3SNUthSVqEaVYCQUpbahI-cGL7MXJ92BcYFNWA0OkJqjKKzgSmxPROr5jKew99wNzXLPjhPMd4z5qYSQrkWpTa1AhRUGrnDZK5BijsoZKVZgmr_fTbn2zl62QY0rMzHS-YvWWde4Ho6gsazQe5vVk4N1tL0Nkex3EeFlWuv547hJiRGuY0Jf_oPdHN1EdTwFoq9x4paMpW1cwbUvKFMEiW91Dpa-Vey3SE1Q6zc8Eb2aCxET5M3a8D4Ftvn75f_bq-5x9dYfdSm7iNjjTR-1smIPFCRTeheCl-pvkHLKxgv5kg40VxKYKwr8BPcIO2g</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2686271702</pqid></control><display><type>article</type><title>Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study</title><source>Open Access: PubMed Central</source><source>Publicly Available Content Database</source><creator>Klich, Sebastian ; Kosendiak, Aureliusz ; Krymski, Igor ; Kawczynski, Adam ; Madeleine, Pascal ; Fernández-de-las-Peñas, Cesar</creator><contributor>Jaafar, Zulkarnain</contributor><creatorcontrib>Klich, Sebastian ; Kosendiak, Aureliusz ; Krymski, Igor ; Kawczynski, Adam ; Madeleine, Pascal ; Fernández-de-las-Peñas, Cesar ; Jaafar, Zulkarnain</creatorcontrib><description>The goal of our study was to investigate the relative and absolute intra-rater and inter-rater reliability of ultrasound assessment of patellar tendon (PT) thickness assessed over four locations, in track cyclists and soccer players. Fifteen male elite track cyclists and 15 male elite soccer players participated. Tendon thickness was measured over 4 locations placed at 5-10-15-20 mm inferior to the apex of the patella by two experienced examiners. Each examiner took two US images for the test measurements with a 10-min rest period. After a 30-min period, the subjects underwent a retest measurements that were also repeated 1-week after. A two-way analysis of variance revealed a significant group x location interaction on PT thickness for Examiner 1 (p = .001, [eta].sup.2 = .81) and Examiner 2 (p = 0.001, [eta].sup.2 = 0.78). Intra-rater reliability ranged from good to excellent (ICC.sub.2,k [greater than or equal to] 0.75), whereas inter-rater reliability was good (ICC.sub.2,k [greater than or equal to] 0.75) in both groups. Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT (corresponding to 15 and 20 mm) can be considered the most reliable spot to measure PT thickness. The PT thickness was larger among track cyclists than soccer players, with larger differences over the distal location (15 mm). Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT corresponding to 15 mm and 20 mm can be considered the most reliable area to measure PT thickness.</description><identifier>ISSN: 1932-6203</identifier><identifier>EISSN: 1932-6203</identifier><identifier>DOI: 10.1371/journal.pone.0270871</identifier><identifier>PMID: 35789336</identifier><language>eng</language><publisher>San Francisco: Public Library of Science</publisher><subject>Bicycling ; Biology and Life Sciences ; Body mass index ; Cyclists ; Evaluation ; Injuries ; Knee ; Magnetic resonance imaging ; Males ; Measurement ; Medicine and Health Sciences ; Musculoskeletal system ; Patellar tendon ; Physical Sciences ; Physiological aspects ; Players ; Reliability analysis ; Research and Analysis Methods ; Soccer ; Soccer players ; Social Sciences ; Thickness measurement ; Ultrasonic imaging ; Ultrasound ; Ultrasound imaging ; Variance analysis</subject><ispartof>PloS one, 2022-07, Vol.17 (7), p.e0270871-e0270871</ispartof><rights>COPYRIGHT 2022 Public Library of Science</rights><rights>2022 Klich et al. This is an open access article distributed under the terms of the Creative Commons Attribution License: http://creativecommons.org/licenses/by/4.0/ (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2022 Klich et al 2022 Klich et al</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323</citedby><cites>FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323</cites><orcidid>0000-0002-8182-2975 ; 0000-0002-2164-234X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2686271702/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2686271702?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids></links><search><contributor>Jaafar, Zulkarnain</contributor><creatorcontrib>Klich, Sebastian</creatorcontrib><creatorcontrib>Kosendiak, Aureliusz</creatorcontrib><creatorcontrib>Krymski, Igor</creatorcontrib><creatorcontrib>Kawczynski, Adam</creatorcontrib><creatorcontrib>Madeleine, Pascal</creatorcontrib><creatorcontrib>Fernández-de-las-Peñas, Cesar</creatorcontrib><title>Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study</title><title>PloS one</title><description>The goal of our study was to investigate the relative and absolute intra-rater and inter-rater reliability of ultrasound assessment of patellar tendon (PT) thickness assessed over four locations, in track cyclists and soccer players. Fifteen male elite track cyclists and 15 male elite soccer players participated. Tendon thickness was measured over 4 locations placed at 5-10-15-20 mm inferior to the apex of the patella by two experienced examiners. Each examiner took two US images for the test measurements with a 10-min rest period. After a 30-min period, the subjects underwent a retest measurements that were also repeated 1-week after. A two-way analysis of variance revealed a significant group x location interaction on PT thickness for Examiner 1 (p = .001, [eta].sup.2 = .81) and Examiner 2 (p = 0.001, [eta].sup.2 = 0.78). Intra-rater reliability ranged from good to excellent (ICC.sub.2,k [greater than or equal to] 0.75), whereas inter-rater reliability was good (ICC.sub.2,k [greater than or equal to] 0.75) in both groups. Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT (corresponding to 15 and 20 mm) can be considered the most reliable spot to measure PT thickness. The PT thickness was larger among track cyclists than soccer players, with larger differences over the distal location (15 mm). Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT corresponding to 15 mm and 20 mm can be considered the most reliable area to measure PT thickness.</description><subject>Bicycling</subject><subject>Biology and Life Sciences</subject><subject>Body mass index</subject><subject>Cyclists</subject><subject>Evaluation</subject><subject>Injuries</subject><subject>Knee</subject><subject>Magnetic resonance imaging</subject><subject>Males</subject><subject>Measurement</subject><subject>Medicine and Health Sciences</subject><subject>Musculoskeletal system</subject><subject>Patellar tendon</subject><subject>Physical Sciences</subject><subject>Physiological aspects</subject><subject>Players</subject><subject>Reliability analysis</subject><subject>Research and Analysis Methods</subject><subject>Soccer</subject><subject>Soccer players</subject><subject>Social Sciences</subject><subject>Thickness measurement</subject><subject>Ultrasonic imaging</subject><subject>Ultrasound</subject><subject>Ultrasound imaging</subject><subject>Variance analysis</subject><issn>1932-6203</issn><issn>1932-6203</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNqNk9-O1CAUxhujcdfRNzCRxMToxYwUWlq8MJls_DPJJpuo6y2hFDrMMjAL1NhH8W2lM9VszV5ILyjw-z44B06WPc_hKsdV_nbnem-5WR2clSuIKlhX-YPsPKcYLQmC-OGd_7PsSQg7CEtcE_I4O8NlVVOMyXn269pEz4PrbQv0nnfadsApcOBRGsM9iNK2zoK41eLGyhCAtkAaHSUIB69tBEktboAYhNEhBsCTz7TuhJAeHAwfpA_vwNombaKXPnn7I5jG0k9jn1S80Uk6gBD7dniaPVLcBPls6hfZ9ccP3y4-Ly-vPm0u1pdLQQiNy4IoXDeqkDksJcW0yEUBW1JiQWrIJeSCwgK3SNUthSVqEaVYCQUpbahI-cGL7MXJ92BcYFNWA0OkJqjKKzgSmxPROr5jKew99wNzXLPjhPMd4z5qYSQrkWpTa1AhRUGrnDZK5BijsoZKVZgmr_fTbn2zl62QY0rMzHS-YvWWde4Ho6gsazQe5vVk4N1tL0Nkex3EeFlWuv547hJiRGuY0Jf_oPdHN1EdTwFoq9x4paMpW1cwbUvKFMEiW91Dpa-Vey3SE1Q6zc8Eb2aCxET5M3a8D4Ftvn75f_bq-5x9dYfdSm7iNjjTR-1smIPFCRTeheCl-pvkHLKxgv5kg40VxKYKwr8BPcIO2g</recordid><startdate>20220705</startdate><enddate>20220705</enddate><creator>Klich, Sebastian</creator><creator>Kosendiak, Aureliusz</creator><creator>Krymski, Igor</creator><creator>Kawczynski, Adam</creator><creator>Madeleine, Pascal</creator><creator>Fernández-de-las-Peñas, Cesar</creator><general>Public Library of Science</general><general>Public Library of Science (PLoS)</general><scope>AAYXX</scope><scope>CITATION</scope><scope>IOV</scope><scope>ISR</scope><scope>3V.</scope><scope>7QG</scope><scope>7QL</scope><scope>7QO</scope><scope>7RV</scope><scope>7SN</scope><scope>7SS</scope><scope>7T5</scope><scope>7TG</scope><scope>7TM</scope><scope>7U9</scope><scope>7X2</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8C1</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB.</scope><scope>KB0</scope><scope>KL.</scope><scope>L6V</scope><scope>LK8</scope><scope>M0K</scope><scope>M0S</scope><scope>M1P</scope><scope>M7N</scope><scope>M7P</scope><scope>M7S</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PATMY</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>PYCSY</scope><scope>RC3</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-8182-2975</orcidid><orcidid>https://orcid.org/0000-0002-2164-234X</orcidid></search><sort><creationdate>20220705</creationdate><title>Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study</title><author>Klich, Sebastian ; Kosendiak, Aureliusz ; Krymski, Igor ; Kawczynski, Adam ; Madeleine, Pascal ; Fernández-de-las-Peñas, Cesar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Bicycling</topic><topic>Biology and Life Sciences</topic><topic>Body mass index</topic><topic>Cyclists</topic><topic>Evaluation</topic><topic>Injuries</topic><topic>Knee</topic><topic>Magnetic resonance imaging</topic><topic>Males</topic><topic>Measurement</topic><topic>Medicine and Health Sciences</topic><topic>Musculoskeletal system</topic><topic>Patellar tendon</topic><topic>Physical Sciences</topic><topic>Physiological aspects</topic><topic>Players</topic><topic>Reliability analysis</topic><topic>Research and Analysis Methods</topic><topic>Soccer</topic><topic>Soccer players</topic><topic>Social Sciences</topic><topic>Thickness measurement</topic><topic>Ultrasonic imaging</topic><topic>Ultrasound</topic><topic>Ultrasound imaging</topic><topic>Variance analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Klich, Sebastian</creatorcontrib><creatorcontrib>Kosendiak, Aureliusz</creatorcontrib><creatorcontrib>Krymski, Igor</creatorcontrib><creatorcontrib>Kawczynski, Adam</creatorcontrib><creatorcontrib>Madeleine, Pascal</creatorcontrib><creatorcontrib>Fernández-de-las-Peñas, Cesar</creatorcontrib><collection>CrossRef</collection><collection>Gale In Context: Opposing Viewpoints</collection><collection>Gale In Context: Science</collection><collection>ProQuest Central (Corporate)</collection><collection>Animal Behavior Abstracts</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Ecology Abstracts</collection><collection>Entomology Abstracts (Full archive)</collection><collection>Immunology Abstracts</collection><collection>Meteorological &amp; Geoastrophysical Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Agricultural Science Collection</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Public Health Database</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Materials Science Database</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Meteorological &amp; Geoastrophysical Abstracts - Academic</collection><collection>ProQuest Engineering Collection</collection><collection>ProQuest Biological Science Collection</collection><collection>Agricultural Science Database</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>ProQuest Biological Science Journals</collection><collection>Engineering Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Environmental Science Database</collection><collection>Materials science collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection><collection>Environmental Science Collection</collection><collection>Genetics Abstracts</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>PloS one</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Klich, Sebastian</au><au>Kosendiak, Aureliusz</au><au>Krymski, Igor</au><au>Kawczynski, Adam</au><au>Madeleine, Pascal</au><au>Fernández-de-las-Peñas, Cesar</au><au>Jaafar, Zulkarnain</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study</atitle><jtitle>PloS one</jtitle><date>2022-07-05</date><risdate>2022</risdate><volume>17</volume><issue>7</issue><spage>e0270871</spage><epage>e0270871</epage><pages>e0270871-e0270871</pages><issn>1932-6203</issn><eissn>1932-6203</eissn><abstract>The goal of our study was to investigate the relative and absolute intra-rater and inter-rater reliability of ultrasound assessment of patellar tendon (PT) thickness assessed over four locations, in track cyclists and soccer players. Fifteen male elite track cyclists and 15 male elite soccer players participated. Tendon thickness was measured over 4 locations placed at 5-10-15-20 mm inferior to the apex of the patella by two experienced examiners. Each examiner took two US images for the test measurements with a 10-min rest period. After a 30-min period, the subjects underwent a retest measurements that were also repeated 1-week after. A two-way analysis of variance revealed a significant group x location interaction on PT thickness for Examiner 1 (p = .001, [eta].sup.2 = .81) and Examiner 2 (p = 0.001, [eta].sup.2 = 0.78). Intra-rater reliability ranged from good to excellent (ICC.sub.2,k [greater than or equal to] 0.75), whereas inter-rater reliability was good (ICC.sub.2,k [greater than or equal to] 0.75) in both groups. Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT (corresponding to 15 and 20 mm) can be considered the most reliable spot to measure PT thickness. The PT thickness was larger among track cyclists than soccer players, with larger differences over the distal location (15 mm). Ultrasonographic assessment of PT was found to be a reliable method to assess tendon thickness. The middle location of the PT corresponding to 15 mm and 20 mm can be considered the most reliable area to measure PT thickness.</abstract><cop>San Francisco</cop><pub>Public Library of Science</pub><pmid>35789336</pmid><doi>10.1371/journal.pone.0270871</doi><tpages>e0270871</tpages><orcidid>https://orcid.org/0000-0002-8182-2975</orcidid><orcidid>https://orcid.org/0000-0002-2164-234X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1932-6203
ispartof PloS one, 2022-07, Vol.17 (7), p.e0270871-e0270871
issn 1932-6203
1932-6203
language eng
recordid cdi_plos_journals_2686271702
source Open Access: PubMed Central; Publicly Available Content Database
subjects Bicycling
Biology and Life Sciences
Body mass index
Cyclists
Evaluation
Injuries
Knee
Magnetic resonance imaging
Males
Measurement
Medicine and Health Sciences
Musculoskeletal system
Patellar tendon
Physical Sciences
Physiological aspects
Players
Reliability analysis
Research and Analysis Methods
Soccer
Soccer players
Social Sciences
Thickness measurement
Ultrasonic imaging
Ultrasound
Ultrasound imaging
Variance analysis
title Ultrasound imaging of patellar tendon thickness in elite sprint track cyclists and elite soccer players: An intra-rater and inter-rater reliability study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T12%3A49%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_plos_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ultrasound%20imaging%20of%20patellar%20tendon%20thickness%20in%20elite%20sprint%20track%20cyclists%20and%20elite%20soccer%20players:%20An%20intra-rater%20and%20inter-rater%20reliability%20study&rft.jtitle=PloS%20one&rft.au=Klich,%20Sebastian&rft.date=2022-07-05&rft.volume=17&rft.issue=7&rft.spage=e0270871&rft.epage=e0270871&rft.pages=e0270871-e0270871&rft.issn=1932-6203&rft.eissn=1932-6203&rft_id=info:doi/10.1371/journal.pone.0270871&rft_dat=%3Cgale_plos_%3EA709256513%3C/gale_plos_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c669t-46f38bf4e105e93941c40d653c680ae0ac9043d2f8d9052d2993fcf099b9c9323%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2686271702&rft_id=info:pmid/35789336&rft_galeid=A709256513&rfr_iscdi=true