Loading…

How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?

Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2023-01, Vol.18 (1), p.e0280433-e0280433
Main Authors: Mahmoudi, Farshid, Mohammadi, Najmeh, Haghighi, Meysam, Alirezaei, Zahra, Jabbari, Iraj, Chegeni, Nahid, Elmtalab, Soheil, Vega-Carrillo, Hector Rene, Kazemian, Ali, Geraily, Ghazale, Karimi, Amir Hossein
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks associated with neutron contamination. In 15 MV SFGRT, high-Z materials such as lead and cerrobend are used as the block on the tray of linear accelerator (linac) which can probably increase the photoneutron production. On the other hand, the high-dose fractions (10-20 Gy) used in SFGRT can induce high neutron contamination. The current study was devoted to addressing these concerns via compression of neutron fluence (Φn) and ambient dose equivalent ([Formula: see text]) at the patient table and inside the maze between SFGRT and conventional fractionated radiation therapy (CFRT). The main components of the 15 MV Siemens Primus equipped with different grids and located inside a typical radiotherapy bunker were simulated by the MCNPX® Monte Carlo code. Evidence showed that the material used for grid construction does not significantly increase neutron contamination inside the maze. However, at the end of the maze, neutron contamination in SFGRT is significantly higher than in CFRT. In this regard, a delay time of 15 minutes after SFGRT is recommended for all radiotherapy staff before entering the maze. It can be also concluded that [Formula: see text] at the patient table is at least 10 times more pronounced than inside the maze. Therefore, the patient is more at risk of neutrons compared to the staff. The [Formula: see text] at the isocenter in SFGRT with grids made of lead and cerrobend was nearly equal to CFRT. Nevertheless, it was dramatically lower than in CFRT by 30% if the brass grid is used. Accordingly, SFGRT with the brass grid is recommended, from radiation protection aspects.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0280433