Loading…

An approach to difficult airway in infants: Comparison of GlideScope® Spectrum LoPro, GlideScope® Spectrum Miller and conventional Macintosh and Miller blades in a simulated Pierre Robin sequence performed by 90 anesthesiologists

Airway management can be challenging in neonates and infants. The Pierre Robin sequence (PRS) is a condition characterized by micrognathia, glossoptosis and airway obstruction. The airway management of these patients poses great challenges for anesthesiologists and pediatricians alike. To date, ther...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2023-08, Vol.18 (8), p.e0288816-e0288816
Main Authors: Irouschek, Andrea, Moritz, Andreas, Kremer, Sven, Fuchte, Tobias, Danzl, Anja, Schmidt, Joachim, Golditz, Tobias
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Airway management can be challenging in neonates and infants. The Pierre Robin sequence (PRS) is a condition characterized by micrognathia, glossoptosis and airway obstruction. The airway management of these patients poses great challenges for anesthesiologists and pediatricians alike. To date, there has been no direct comparison of the hyperangulated GlideScope® Spectrum LoPro (GLP), the straight GlideScope® Spectrum Miller (GSM), a conventional Macintosh (MC) and a conventional Miller blade (ML) in patients with PRS. For this purpose, 90 anesthesiologists (43 with limited experience, 47 with extensive experience) performed orotracheal intubation on an Air-Sim® Pierre Robin X manikin using GLP, GSM, MC and ML in randomized order. 'Time-to-vocal-cords', 'time-to-intubate', 'time-to-ventilate', the severity of oral-soft-tissue-trauma and the subjective evaluation of each device were recorded. A significantly faster and better view of the vocal cords and lower oral-soft-tissue-trauma was achieved using the GLP (p120s) with the GLP. In the sub-group with extensive experience, we found significantly shorter intubation times for the GSM and ML. The GLP was the tool of choice for most participants, while the conventional MC received the lowest rating. Videolaryngoscopy leads to increased safety for the prevention of undetected esophageal intubation in the airway management in a PRS manikin. Hyperangulated blades may ensure a good and fast view of the vocal cords and low oral-soft-tissue-trauma but pose a challenge during the placement of the tube. Specific skills and handling seem to be necessary to ensure a safe tube placement with this sort of blades.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0288816