Loading…
NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS
Current voltage characteristics are the main tool to control the operation of the ESP fields and to detect the back Corona. The collecting efficiency of an ESP depends on the large number of parameters. An important parameter is the current emitted from the discharge electrodes and collecting plates...
Saved in:
Published in: | Acta Technica Corvininesis 2012-04, Vol.5 (2), p.93 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | 2 |
container_start_page | 93 |
container_title | Acta Technica Corvininesis |
container_volume | 5 |
creator | Popa, Gabriel Nicolae Deaconu, Sorin Ioan Popa, Iosif Dinis, Corina Maria |
description | Current voltage characteristics are the main tool to control the operation of the ESP fields and to detect the back Corona. The collecting efficiency of an ESP depends on the large number of parameters. An important parameter is the current emitted from the discharge electrodes and collecting plates. Generally, the higher secondary current the better are collecting performances. Some parameters, like back Corona discharges, high resistivity fly ash reduce the collecting performances of the ESP. The paper presents some new methods detection of back-Corona discharges in plate-type electrostatic precipitators. [PUBLICATION ABSTRACT] |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_1012153889</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2657218651</sourcerecordid><originalsourceid>FETCH-proquest_journals_10121538893</originalsourceid><addsrcrecordid>eNqNi9EKgjAYhUcQJOU7DLoebGmml2v-5kg2mT9EEEgXdiGRpfn-SfQAnZvD4fvOjHgbHu1YEPNkQfxhaPmUiAehCD1yMXCi6MCkFdWGpoCgUFtDbUb3Uh2Zss4aSVNdqVy6A3y1spAIDM8lUCimg7MVStSKlg6ULvU0rMNqRea3631o_F8vyToDVDl79t1rbIZ33XZj_5hQLbjYiG0Qx0nwn_UByNQ6XA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1012153889</pqid></control><display><type>article</type><title>NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS</title><source>Publicly Available Content Database</source><creator>Popa, Gabriel Nicolae ; Deaconu, Sorin Ioan ; Popa, Iosif ; Dinis, Corina Maria</creator><creatorcontrib>Popa, Gabriel Nicolae ; Deaconu, Sorin Ioan ; Popa, Iosif ; Dinis, Corina Maria</creatorcontrib><description>Current voltage characteristics are the main tool to control the operation of the ESP fields and to detect the back Corona. The collecting efficiency of an ESP depends on the large number of parameters. An important parameter is the current emitted from the discharge electrodes and collecting plates. Generally, the higher secondary current the better are collecting performances. Some parameters, like back Corona discharges, high resistivity fly ash reduce the collecting performances of the ESP. The paper presents some new methods detection of back-Corona discharges in plate-type electrostatic precipitators. [PUBLICATION ABSTRACT]</description><identifier>EISSN: 2067-3809</identifier><language>eng</language><publisher>Hunedoara: Faculty of Engineering Hunedoara</publisher><subject>Coal ; Dust ; Efficiency ; Flue gas ; Power supply ; Trends</subject><ispartof>Acta Technica Corvininesis, 2012-04, Vol.5 (2), p.93</ispartof><rights>Copyright Faculty of Engineering Hunedoara Apr-Jun 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/1012153889/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/1012153889?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Popa, Gabriel Nicolae</creatorcontrib><creatorcontrib>Deaconu, Sorin Ioan</creatorcontrib><creatorcontrib>Popa, Iosif</creatorcontrib><creatorcontrib>Dinis, Corina Maria</creatorcontrib><title>NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS</title><title>Acta Technica Corvininesis</title><description>Current voltage characteristics are the main tool to control the operation of the ESP fields and to detect the back Corona. The collecting efficiency of an ESP depends on the large number of parameters. An important parameter is the current emitted from the discharge electrodes and collecting plates. Generally, the higher secondary current the better are collecting performances. Some parameters, like back Corona discharges, high resistivity fly ash reduce the collecting performances of the ESP. The paper presents some new methods detection of back-Corona discharges in plate-type electrostatic precipitators. [PUBLICATION ABSTRACT]</description><subject>Coal</subject><subject>Dust</subject><subject>Efficiency</subject><subject>Flue gas</subject><subject>Power supply</subject><subject>Trends</subject><issn>2067-3809</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNi9EKgjAYhUcQJOU7DLoebGmml2v-5kg2mT9EEEgXdiGRpfn-SfQAnZvD4fvOjHgbHu1YEPNkQfxhaPmUiAehCD1yMXCi6MCkFdWGpoCgUFtDbUb3Uh2Zss4aSVNdqVy6A3y1spAIDM8lUCimg7MVStSKlg6ULvU0rMNqRea3631o_F8vyToDVDl79t1rbIZ33XZj_5hQLbjYiG0Qx0nwn_UByNQ6XA</recordid><startdate>20120401</startdate><enddate>20120401</enddate><creator>Popa, Gabriel Nicolae</creator><creator>Deaconu, Sorin Ioan</creator><creator>Popa, Iosif</creator><creator>Dinis, Corina Maria</creator><general>Faculty of Engineering Hunedoara</general><scope>3V.</scope><scope>7XB</scope><scope>8FE</scope><scope>8FG</scope><scope>8FK</scope><scope>8G5</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M2O</scope><scope>M7S</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>Q9U</scope></search><sort><creationdate>20120401</creationdate><title>NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS</title><author>Popa, Gabriel Nicolae ; Deaconu, Sorin Ioan ; Popa, Iosif ; Dinis, Corina Maria</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_10121538893</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Coal</topic><topic>Dust</topic><topic>Efficiency</topic><topic>Flue gas</topic><topic>Power supply</topic><topic>Trends</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Popa, Gabriel Nicolae</creatorcontrib><creatorcontrib>Deaconu, Sorin Ioan</creatorcontrib><creatorcontrib>Popa, Iosif</creatorcontrib><creatorcontrib>Dinis, Corina Maria</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>ProQuest research library</collection><collection>Engineering Database</collection><collection>Research Library (Corporate)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection><collection>ProQuest Central Basic</collection><jtitle>Acta Technica Corvininesis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Popa, Gabriel Nicolae</au><au>Deaconu, Sorin Ioan</au><au>Popa, Iosif</au><au>Dinis, Corina Maria</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS</atitle><jtitle>Acta Technica Corvininesis</jtitle><date>2012-04-01</date><risdate>2012</risdate><volume>5</volume><issue>2</issue><spage>93</spage><pages>93-</pages><eissn>2067-3809</eissn><abstract>Current voltage characteristics are the main tool to control the operation of the ESP fields and to detect the back Corona. The collecting efficiency of an ESP depends on the large number of parameters. An important parameter is the current emitted from the discharge electrodes and collecting plates. Generally, the higher secondary current the better are collecting performances. Some parameters, like back Corona discharges, high resistivity fly ash reduce the collecting performances of the ESP. The paper presents some new methods detection of back-Corona discharges in plate-type electrostatic precipitators. [PUBLICATION ABSTRACT]</abstract><cop>Hunedoara</cop><pub>Faculty of Engineering Hunedoara</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2067-3809 |
ispartof | Acta Technica Corvininesis, 2012-04, Vol.5 (2), p.93 |
issn | 2067-3809 |
language | eng |
recordid | cdi_proquest_journals_1012153889 |
source | Publicly Available Content Database |
subjects | Coal Dust Efficiency Flue gas Power supply Trends |
title | NEW TRENDS IN DETECTION OF BACK-CORONA DISCHARGES IN PLATE-TYPE ELECTROSTATIC PRECIPITATORTS |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A18%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=NEW%20TRENDS%20IN%20DETECTION%20OF%20BACK-CORONA%20DISCHARGES%20IN%20PLATE-TYPE%20ELECTROSTATIC%20PRECIPITATORTS&rft.jtitle=Acta%20Technica%20Corvininesis&rft.au=Popa,%20Gabriel%20Nicolae&rft.date=2012-04-01&rft.volume=5&rft.issue=2&rft.spage=93&rft.pages=93-&rft.eissn=2067-3809&rft_id=info:doi/&rft_dat=%3Cproquest%3E2657218651%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_10121538893%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1012153889&rft_id=info:pmid/&rfr_iscdi=true |