Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair Reference values

Four multi-elementary metal and metalloid quantification methods using inductively coupled plasma mass spectrometry (ICP-MS) were developed and validated in human whole blood, plasma, urine and hair by means of a single preparation procedure for each sample. The ICP-MS measurements were performed us...

Full description

Saved in:
Bibliographic Details
Published in:Forensic science international 2005-10, Vol.153 (1), p.39-44
Main Authors: GOULLE, Jean-Pierre, MAHIEU, Loïc, CASTERMANT, Julien, NEVEU, Nicolas, BONNEAU, Laurent, LAINE, Gilbert, BOUIGE, Daniel, LACROIX, Christian
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Four multi-elementary metal and metalloid quantification methods using inductively coupled plasma mass spectrometry (ICP-MS) were developed and validated in human whole blood, plasma, urine and hair by means of a single preparation procedure for each sample. The ICP-MS measurements were performed using a Thermo Elemental X7CCT series and PlasmaLab software without a dynamic reaction cell. With this procedure 27-32 elements can be simultaneously quantified in biological matrices: Li, Be, B, Al, V, Cr, Mn, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Rb, Sr, Mo, Pd, Ag, Cd, Sn, Sb, Te, Ba, W, Pt, Hg, Tl, Pb, Bi, U. Whole blood, plasma and urine samples (0.4 ml each) were diluted with purified water, acid, triton X100 and butanol. Rhodium was used as internal standard. The urine sample results were corrected for enzymatic creatinine determination. Twenty-five milligrams hair samples were acid mineralized after a decontamination procedure and diluted as previously described for biological fluids. To be validated, each element had to show linearity with a correlation coefficient higher than 0.99. The intra-assay and inter-assay inaccuracy, measured as the variation coefficient, were below 5 and 10% respectively. Global performance was assessed by a quality control program. Our laboratory is a registered participant of the Institut National de Santé Publique du Québec (Sainte-Foy, Canada) inter-laboratory comparison program for whole blood, urine, and beard hair of non-occupationally exposed individuals spiked with selected elements. In our study multi-element metal and metalloid analysis was assessed for 27 elements in whole blood, 27 elements in plasma, 30 elements in urine and 32 elements in hair, from 0 to 25, or 250 to 1000 ng/ml, depending on the element. Quantification limits ranged from 0.002 ng/ml (U) to 8.1 ng/ml (Al) for whole blood, from 0.002 ng/ml (U) to 7.7 ng/ml (Al) for plasma, from 0.001 ng/ml (U) to 2.2 ng/ml (Se) for urine, and from 0.2 pg/mg (Tl) to 0.5 ng/mg (B) for hair. Normal values were determined in whole blood (n=100), plasma (n=100), urine (n=100), and hair (n=45) of healthy volunteers, leading to approximately 10,000 analyses. All results are presented and discussed. Clinical toxicology and forensic toxicology applications are also reported. ICP-MS has made significant advances in the field of clinical biology, particularly in toxicological analysis. This is due to the use of extremely effective equipment that permits better clinical and forensi
ISSN:0379-0738
1872-6283
DOI:10.1016/j.forsciint.2005.04.020